The DOI matches its Crossref record; 31 of the 31 references it cites were found in a registry or an index.
Identification of Proteins in Complexes by Solid-Phase Microextraction/Multistep Elution/Capillary Electrophoresis/Tandem Mass Spectrometry
Abstract
A method to directly identify proteins in complex mixtures by solid-phase microextraction (micro-SPE)/multistep elution/capillary electrophoresis (CE)/tandem mass spectrometry (MS/MS) is described. A sheathless liquid-metal junction interface is used to interface CE and electrospray ionization MS/MS. A subfemtomole detection limit is achieved for protein identification through database searching using MS/MS data. The SPE serves as a semiseparation dimension using an organic-phase step-elution gradient in combination with the second separation dimension for increased resolving power of complex peptide mixtures. This approach improves the concentration detection limit for CE and allows more proteins in complex mixtures to be identified. A 75-protein complex from yeast ribosome is analyzed using this method and 80-90% of the proteins in the complex can be identified by searching the database using the MS/MS data from a complete analysis. This multidimensional CE/MS/MS methodology provides an alternative to multidimensional liquid chromatography/MS/MS for direct identification of small amounts of protein in mixtures.
Overview
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
Citations
Cites
Bradford, M. M. (1976) · Analytical Biochemistry · doi:10.1016/0003-2697(76)90527-3 · Cited by 255,302
Eng, J. K., McCormack, A. L., & Yates, J. R. (1994) · Journal of the American Society for Mass Spectrometry · doi:10.1016/1044-0305(94)80016-2 · Cited by 6,484
Self-citationCharacterization of Peptides Bound to the Class I MHC Molecule HLA-A2.1 by Mass Spectrometry
Hunt, D. F., Henderson, R. A., Shabanowitz, J., Sakaguchi, K., Michel, H., Sevilir, N., Cox, A. L., Appella, E., & Engelhard, V. H. (1992) · Science · doi:10.1126/science.1546328 · Cited by 1,198
Int. J. Mass Spectrom. Ion Processes
(1990) · International Journal of Mass Spectrometry and Ion Processes · doi:10.1016/0168-1176(90)80022-u · Cited by 1,003
McCormack, A. L., Schieltz, D. M., Goode, B., Yang, S., Barnes, G., Drubin, D., & Yates, J. R. (1997) · Analytical Chemistry · doi:10.1021/ac960799q · Cited by 523
Self-citationGatlin, C. L., Kleemann, G. R., Hays, L. G., Link, A. J., & Yates, J. R. (1998) · Analytical Biochemistry · doi:10.1006/abio.1998.2809 · Cited by 391
Self-citationComprehensive On-Line LC/LC/MS of Proteins
Opiteck, G. J., Lewis, K. C., Jorgenson, J. W., & Anderegg, R. J. (1997) · Analytical Chemistry · doi:10.1021/ac961155l · Cited by 286
Two-Dimensional SEC/RPLC Coupled to Mass Spectrometry for the Analysis of Peptides
Opiteck, G. J., Jorgenson, J. W., & Anderegg, R. J. (1997) · Analytical Chemistry · doi:10.1021/ac961156d · Cited by 278
STUDIES ON THE COMPOSITION OF THE PROTEIN FROM ESCHERICHIA COLI RIBOSOMES
Waller, J.-P., & Harris, J. I. (1961) · Proceedings of the National Academy of Sciences · doi:10.1073/pnas.47.1.18 · Cited by 193
Figeys, D., Ducret, A., Yates, J. R., & Aebersold, R. (1996) · Nature Biotechnology · doi:10.1038/nbt1196-1579 · Cited by 187
Self-citationWahl, J. H., Gale, D. C., & Smith, R. D. (1994) · Journal of Chromatography A · doi:10.1016/0021-9673(94)85026-7 · Cited by 176
Foret, F., Szökő, E., & Karger, B. L. (1993) · ELECTROPHORESIS · doi:10.1002/elps.1150140167 · Cited by 173
Thompson, T. J., Foret, F., Vouros, P., & Karger, B. L. (1993) · Analytical Chemistry · doi:10.1021/ac00055a012 · Cited by 167
Isotachophoresis as an on-line concentration pretreatment technique in capillary electrophoresis
Stegehuis, D. S., Irthu, H., Tjaden, U. R., & van der Greef, J. (1991) · Journal of Chromatography A · doi:10.1016/s0021-9673(01)88860-9 · Cited by 148
Figeys, D., van Oostveen, I., Ducret, A., & Aebersold, R. H. (1996) · Analytical Chemistry · doi:10.1021/ac960191h · Cited by 135
Determination of bioactive peptides using capillary zone electrophoresis/mass spectrometry
Moseley, M. A., Deterding, L. J., Tomer, K. B., & Jorgenson, J. W. (1991) · Analytical Chemistry · doi:10.1021/ac00002a005 · Cited by 134
Bruin, G. J. M., Huisden, R. E., Kraak, J. C., et al. (1989) · Journal of Chromatography A · doi:10.1016/s0021-9673(01)84303-x · Cited by 134
Davis, M. T., & Lee, T. D. (1998) · Journal of the American Society for Mass Spectrometry · doi:10.1016/s1044-0305(97)00282-1 · Cited by 131
Disposable Emitters for On-line Capillary Zone Electrophoresis/Nanoelectrospray Mass Spectrometry
Bateman, K. P., White, R. L., & Thibault, P. (1997) · Rapid Communications in Mass Spectrometry · doi:10.1002/(sici)1097-0231(19970215)11:3<307::aid-rcm850>3.0.co;2-m · Cited by 118
Wahl, J. H., Goodlett, D. R., Udseth, H. R., et al. (1993) · Electrophoresis · doi:10.1002/elps.1150140170 · Cited by 86
Tomlinson, A. J., Benson, L. M., Jameson, S. C., et al. (1997) · Journal of the American Society for Mass Spectrometry · doi:10.1016/s1044-0305(96)00133-x · Cited by 83
Li, M. X., Liu, L., Wu, J.-T., et al. (1997) · Analytical Chemistry · doi:10.1021/ac970076m · Cited by 77
Davis, M. T., Stahl, D. C., & Lee, T. D. (1995) · Journal of the American Society for Mass Spectrometry · doi:10.1016/1044-0305(95)00192-g · Cited by 70
Debets, A. J. J., Mazereeuw, M., Voogt, W. H., et al. (1992) · Journal of Chromatography A · doi:10.1016/0021-9673(92)87117-q · Cited by 69
Tomlinson, A. J., & Naylor, S. (1995) · Journal of Liquid Chromatography · doi:10.1080/10826079508014613 · Cited by 67
Tomlinson, A. J., Benson, L. M., Jameson, S. C., & Naylor, S. (1996) · Electrophoresis · doi:10.1002/elps.1150171203 · Cited by 57
Reduced elution speed detection for capillary electrophoresis/mass spectrometry
Goodlett, D. R., Wahl, J. H., Udseth, H. R., et al. (1993) · Journal of Microcolumn Separations · doi:10.1002/mcs.1220050109 · Cited by 57
On‐line preconcentration‐capillary electrophoresis‐mass spectrometry (PC‐CE‐MS)
Tomlinson, A. J., Benson, L. M., Braddock, W. D., et al. (1994) · Journal of High Resolution Chromatography · doi:10.1002/jhrc.1240171010 · Cited by 51
Tomlinson, A. J., & Naylor, S. (1995) · Journal of High Resolution Chromatography · doi:10.1002/jhrc.1240180613 · Cited by 42
High resolution mini-two-dimensional gel electrophoresis of yeast ribosomal proteins
BOLLEN, G. H. P. M., Mager, W. H., & Planta, R. J. (1981) · Molecular Biology Reports · doi:10.1007/bf00798383 · Cited by 27
[46] Preparation of active 60 S and 40 S subunits from yeast ribosomes
Battaner, E., & Vázquez, D. (1971) · Methods in enzymology on CD-ROM/Methods in enzymology · doi:10.1016/s0076-6879(71)20048-3 · Cited by 20
Research works printed but not linked: 4
- Yates J. R., 1996, Use of mass spectrometry fragmentation patterns of peptides to identify amino acid sequences in databases. U.S. Patent 5,538,897
- Tomlinson A. J., 1995, J. Capillary Electrophor., 2, 247
- Tomlinson A. J., 1995, J. Capillary Electrophor., 2, 247
- Guzman N. A., 1999, LC-GC, 17, 16
Cited by
An Automated Multidimensional Protein Identification Technology for Shotgun Proteomics
Wolters, D. A., Washburn, M. P., & Yates, J. R. (2001) · Analytical Chemistry · doi:10.1021/ac010617e · Cited by 1,819
Self-citationPeng, J., Elias, J. E., Thoreen, C. C., Licklider, L. J., & Gygi, S. P. (2003) · Journal of Proteome Research · doi:10.1021/pr025556v · Cited by 1,647
Mass Spectrometry in Proteomics
Aebersold, R., & Goodlett, D. R. (2001) · Chemical Reviews · doi:10.1021/cr990076h · Cited by 1,238
Molecular Biologist's Guide to Proteomics
Graves, P. R., & Haystead, T. A. J. (2002) · Microbiology and Molecular Biology Reviews · doi:10.1128/mmbr.66.1.39-63.2002 · Cited by 691
Mass Spectral Analysis in Proteomics
Yates, J. R. (2004) · Annual Review of Biophysics and Biomolecular Structure · doi:10.1146/annurev.biophys.33.111502.082538 · Cited by 326
Self-citation
Metadata
- Authors
- Tong, W., Link, A., Eng, J. K., & Yates, J. R.
- Affiliations
- University of Washington (US)
- Corresponding author
- Yates, John R.
- Venue
- Analytical Chemistry
- Publisher
- American Chemical Society (ACS)
- Published
- 1999-05-26
- Volume
- 71
- Issue
- 13
- Pages
- 2270-2278
- ISSN
- 0003-2700 (ISSN-L)
- 1520-6882
- OpenAlex
- W1994804505
- Cited by
- 143
- References
- 31
- Citations by year
- 2026: 1 · 2025: 2 · 2024: 2 · 2022: 3 · 2021: 3 · 2020: 4 · 2019: 2 · 2018: 3 · 2017: 1 · 2016: 2 · 2015: 4 · 2014: 9 · 2013: 9 · 2012: 4
- FWCI
- 7.88
- Type
- journal article
- Language
- en
- Open access
- closed
- Locations
- Analytical Chemistry (publishedVersion)
- PubMed (publishedVersion)
- Funders
- National Science Foundation
- National Institutes of Health (5r01gm052095-03)
- National Institute of General Medical Sciences (GM52095)
- Topics
- Physical Sciences › Chemistry › Spectroscopy › Advanced Proteomics Techniques and Applications
- Physical Sciences › Engineering › Biomedical Engineering › Microfluidic and Capillary Electrophoresis Applications
- Physical Sciences › Chemistry › Spectroscopy › Mass Spectrometry Techniques and Applications
- Keywords
- protein identification, solid-phase microextraction, capillary electrophoresis, tandem mass spectrometry, electrospray ionization, peptide mixtures, yeast ribosome, database searching, multidimensional separation
- MeSH terms
- Hydrolysis, Proteins, Mass Spectrometry, Trypsin, Electrophoresis, Capillary
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.