The DOI matches its Crossref record; 1 of the 1 references it cites were found in a registry or an index.
Effect of Experimental Parameters on the ESI FT-ICR Mass Spectrum of Fulvic Acid
Abstract
Fulvic acid (FA) is a heterogeneous mixture of organic macromolecules found in the waters, soils, and sediments of the earth's surface. The ability of electrospray ionization (ESI) to effectively transfer large ions from the solution phase to the gas phase and the coupling of ESI to the high-mass-resolution capabilities of Fourier transform ion cyclotron resonance mass spectrometry (FT-ICR MS) provide a potential method for the mass spectrometric analysis of FA. Positive- and negative-ion ESI FT-ICR MS analyses of four reference International Humic Substances Society FAs were performed. The spray solution composition was found to have a dramatic effect on the ion distributions, with high-mass aggregates (m/z approximately 2000-4000) being formed in less polar spray solutions. Positive-ion spectra for each FA obtained under optimum conditions resulted in number-average molecular weights ranging from 1700 to 1900. The mass spectra were extremely complex, with ion distributions on the order of m/z approximately 500-3000. The presence of more than one ion at each nominal mass was routinely observed. Negative-ion ESI analysis of the FA samples resulted in the observation of multiply charged ions whose distributions could be affected by the acidification of the spray solution. Solution parameters which have been reported to affect molecular weight distributions of FA such as pH, ionic strength, and concentration of multivalent cations were found to have little or no effect on the observed m/z distributions.
Overview
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Open-endcap Penning traps for high precision experiments
Gabrielse, G., Haarsma, L., & Rolston, S. L. (1989) · International Journal of Mass Spectrometry and Ion Processes · doi:10.1016/0168-1176(89)85027-x · Cited by 288
Cited by
Molecular structure in soil humic substances: the new view
Sutton, R., & Sposito, G. (2005) · Environmental Science & Technology · doi:10.1021/es050778q · Cited by 1,316
21 Tesla FT-ICR Mass Spectrometer for Ultrahigh-Resolution Analysis of Complex Organic Mixtures
Smith, D. F., Podgorski, D. C., Rodgers, R. P., Blakney, G. T., & Hendrickson, C. L. (2018) · Analytical Chemistry · doi:10.1021/acs.analchem.7b04159 · Cited by 348
Use of Fluorescent DNA-Templated Gold/Silver Nanoclusters for the Detection of Sulfide Ions
Chen, W.-Y., Lan, G.-Y., & Chang, H.-T. (2011) · Analytical Chemistry · doi:10.1021/ac202162u · Cited by 283
Metadata
- Authors
- Brown, T. L., & Rice, J. A.
- Venue
- Analytical Chemistry
- Publisher
- American Chemical Society (ACS)
- Published
- 1999-12-08
- Volume
- 72
- Issue
- 2
- Pages
- 384-390
- ISSN
- 0003-2700 (ISSN-L)
- 1520-6882
- OpenAlex
- W2010332398
- Cited by
- 160
- References
- 1
- FWCI
- 4.26
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: Effect of Experimental Parameters on the ESI FT-ICR Mass Spectrum of Fulvic Acid. https://app.cochat.ai/papers/10.1021/ac9902087
- The paper
- Brown, T. L., & Rice, J. A. (2000). Effect of Experimental Parameters on the ESI FT-ICR Mass Spectrum of Fulvic Acid. Analytical Chemistry. https://doi.org/10.1021/ac9902087
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.