Separation of Isomeric Peptides Using Electrospray Ionization/High-Resolution Ion Mobility Spectrometry
Abstract
In this paper, the first examples of baseline separation of isomeric macromolecules by electrospray ionization/ion mobility spectrometry (ESI/IMS) at atmospheric pressure are presented. The behavior of a number of different isomeric peptides in the IMS was investigated using nitrogen as a drift gas. The IMS was coupled to a quadrupole mass spectrometer, which was used for identification and selective detection of the electrosprayed ions. The mobility data were used to determine their average collision cross sections. The gas-phase ions of isomeric peptides were found to have different collision cross sections. In all cases, doubly charged ions exhibited significantly (8-20%) larger collision cross sections than the respective singly charged species. The analysis of mixtures of the isomeric peptides clearly demonstrated the capability of IMS to separate gas-phase peptide ions due to small differences in their conformational structures, which cannot be determined by mass spectrometry. An actual resolving power of 80 was achieved for two doubly charged reversed sequenced pentapeptides. Baseline separation was provided for ions differing by only 2.5% in their measured collision cross sections; partial separation was shown for isomeric ions exhibiting differences as small as 1.1%.
Overview
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cited by
Ion mobility–mass spectrometry
Kanu, A. B., Dwivedi, P., Tam, M., Matz, L., & Hill, H. H. (2008) · Journal of Mass Spectrometry · doi:10.1002/jms.1383 · Cited by 1,154
Self-citationRecommendations for reporting ion mobility Mass Spectrometry measurements
Gabelica, V., Shvartsburg, A. A., Afonso, C., Barran, P., Benesch, J. L. P., Bleiholder, C., Bowers, M. T., Bilbao, A., Bush, M. F., Campbell, J. L., et al. (2019) · Mass Spectrometry Reviews · doi:10.1002/mas.21585 · Cited by 493
Ion Mobility Spectrometry: Principles and Applications
Borsdorf, H., & Eiceman, G. A. (2006) · Applied Spectroscopy Reviews · doi:10.1080/05704920600663469 · Cited by 395
Campuzano, I., Bush, M. F., Robinson, C. V., Beaumont, C., Richardson, K., Kim, H., & Kim, H. I. (2012) · Analytical Chemistry · doi:10.1021/ac202625t · Cited by 383
Yukioka, S., Tanaka, S., Suzuki, Y., Echigo, S., & Fujii, S. (2021) · Journal of Chromatography A · doi:10.1016/j.chroma.2021.461899 · Cited by 22
Metadata
- Authors
- Wu, C., Siems, W. F., Klasmeier, J., & Hill, H. H.
- Venue
- Analytical Chemistry
- Publisher
- American Chemical Society (ACS)
- Published
- 1999-12-14
- Volume
- 72
- Issue
- 2
- Pages
- 391-395
- ISSN
- 0003-2700 (ISSN-L)
- 1520-6882
- OpenAlex
- W1977690909
- Cited by
- 207
- References
- 0
- FWCI
- 2.99
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: Separation of Isomeric Peptides Using Electrospray Ionization/High-Resolution Ion Mobility Spectrometry. https://app.cochat.ai/papers/10.1021/ac990601c
- The paper
- Wu, C., Siems, W. F., Klasmeier, J., & Hill, H. H. (2000). Separation of Isomeric Peptides Using Electrospray Ionization/High-Resolution Ion Mobility Spectrometry. Analytical Chemistry. https://doi.org/10.1021/ac990601c
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.