Student or educator? Sign up with your school email and get 6 months of Pro free.
Cited by 283

The DOI matches its Crossref record; 8 of the 8 references it cites were found in a registry or an index.

Electrochemical Pretreatment of Polycrystalline Gold Electrodes To Produce a Reproducible Surface Roughness for Self-Assembly: A Study in Phosphate Buffer pH 7.4

Hoogvliet, J. C., Dijksma, M., Kamp, B., van Bennekom, W. P.·2000·Analytical Chemistry

Abstract

It has been emphasized in several studies that the state of the surface, including the surface roughness, is very important for the reproducible formation of high-quality self-assembled monolayers on gold. The pulsed-potential pretreatment procedure described in this paper can, in a reproducible way, reduce the surface roughness of mechanically polished polycrystalline gold electrodes by a factor 2. The developed procedure, in which the gold is alternately oxidized and reduced, has been optimized for use in a flow system (100 mM phosphate buffer pH 7.4). The influence of the pretreatment procedure on the surface roughness of the electrodes has been studied by in-situ oxygen adsorption measurements using cyclic voltammetry. The most effective pulse regime in producing a gold surface with a reproducible and relatively low surface roughness is a triple-potential pulse waveform, with potentials of +1.6, 0.0, and -0.8 Vvs SCE and pulse widths of 100 ms for each potential. Prolonged pulsing for 2000-5000 s with the gold working electrode in a flow-through cell showed an electropolishing effect, i.e., a decrease of the roughness in time. Flow conditions are very important: the roughness decreased faster at higher flow rates, while an increase was observed without flow. A process of reconstruction and dissolution of gold during application of the potential pulses under flow conditions is assumed to account for the observed phenomena. A self-assembled monolayer of thioctic acid with reproducible characteristics, determined with impedance measurements, could be formed on a pretreated gold surface.

Overview

The claims and statistics of this paper haven’t been checked yet.

Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.

A few free checks a day · papers already verified open instantly · results are public

Integrity signals

Registry

Crossref · 10.1021/ac991215y

Cites

8 of 8 references verified0 citation errors · 0 not checkable

Statistics

Verification

Claims the paper makes

The claims and statistics of this paper haven’t been checked yet.

Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.

A few free checks a day · papers already verified open instantly · results are public

Self-check

Percentages, sums and reported differences re-computed from the paper’s own numbers.

The self-check needs the paper’s full text.

Citations

Cites

Show all 8 references

Cited by

Metadata

Authors
Hoogvliet, J. C., Dijksma, M., Kamp, B., & van Bennekom, W. P.
Venue
Analytical Chemistry
Published
2000-03-24
Volume
72
Issue
9
Pages
2016-2021
ISSN
  • 0003-2700 (ISSN-L)
  • 1520-6882
OpenAlex
W2050137045
Cited by
283
References
8
FWCI
4.33
Type
journal article
Language
en
Open access
closed

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review

How to cite

Cite CoChat for the checks on this page, and the paper for its own findings.

This page
CoChat. (2026). Citation check: Electrochemical Pretreatment of Polycrystalline Gold Electrodes To Produce a Reproducible Surface Roughness for Self-Assembly: A Study in Phosphate Buffer pH 7.4. https://app.cochat.ai/papers/10.1021/ac991215y
The paper
Hoogvliet, J. C., Dijksma, M., Kamp, B., & van Bennekom, W. P. (2000). Electrochemical Pretreatment of Polycrystalline Gold Electrodes To Produce a Reproducible Surface Roughness for Self-Assembly: A Study in Phosphate Buffer pH 7.4. Analytical Chemistry. https://doi.org/10.1021/ac991215y

Data sources

Bibliographic data: Semantic Scholar, OpenAlex, Crossref.

Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).

Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.