The DOI matches its Crossref record; 1 of the 1 references it cites were found in a registry or an index.
Isoelectric Focusing Nonporous RP HPLC: A Two-Dimensional Liquid-Phase Separation Method for Mapping of Cellular Proteins with Identification Using MALDI-TOF Mass Spectrometry
Abstract
A novel two-dimensional liquid-phase separation method was developed that is capable of resolving large numbers of cellular proteins. The proteins are separated by pI using isoelectric focusing in the first dimension and by hydrophobicity using nonporous reversed-phase HPLC in the second dimension (IEF-NP RP HPLC). Proteins were mapped using original software in order to create a protein pattern analogous to that of the 2-D PAGE image. RP HPLC peaks are represented by bands of different intensity in the 2-D image, according to the intensity of the peaks eluting from the HPLC. Each peak was collected as the eluent of the HPLC separation in the liquid phase. The proteins collected were identified using proteolytic enzymes, MALDI-TOF MS and MSFit database searching. Using IEF-NP RP HPLC, approximately 700 bands were resolved in a pI range from 3.2 to 9.5 and 38 different proteins with molecular weights ranging from 12,000 to 75,000 were identified. In comparison to a 2-D gel separation of the same human erythroleukemia cell line lysate, the IEF-NP RP HPLC produced improved resolution of low mass and basic proteins. In addition, the proteins remained in the liquid phase throughout the separation, thus making the entire procedure highly amenable to automation and high throughput. It is demonstrated that IEF-NP RP HPLC provides a viable alternative to the 2-D gel separation method for the screening of protein profiles.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Nagata, S., & Golstein, P. (1995) · Science · doi:10.1126/science.7533326 · Cited by 3,979
Cited by
Mass Spectrometry in Proteomics
Aebersold, R., & Goodlett, D. R. (2001) · Chemical Reviews · doi:10.1021/cr990076h · Cited by 1,238
Emerging molecular markers of cancer
Sidransky, D. (2002) · Nature Reviews Cancer · doi:10.1038/nrc755 · Cited by 662
Pieper, R., Gatlin, C. L., Makusky, A. J., Russo, P. S., Schatz, C. R., Miller, S. S., Su, Q., McGrath, A. M., Estock, M. A., Parmar, P. P., et al. (2003) · PROTEOMICS · doi:10.1002/pmic.200300449 · Cited by 518
Top Down proteomics: Facts and perspectives
Catherman, A. D., Skinner, O. S., & Kelleher, N. L. (2014) · Biochemical and Biophysical Research Communications · doi:10.1016/j.bbrc.2014.02.041 · Cited by 507
“Isoelectric focusing (IEF) for Top Down proteomics is generally considered more difficult as proteins tend to precipitate at their isoelectric point, significantly reducing their recovery from the gel media [18].”
BackgroundMethodGilar, M., Olivova, P., Daly, A. E., & Gebler, J. C. (2005) · Journal of Separation Science · doi:10.1002/jssc.200500116 · Cited by 425
Metadata
- Authors
- Wall, D. B., Kachman, M. T., Gong, S., Hinderer, R., Parus, S., Misek, D. E., Hanash, S. M., & Lubman, D. M.
- Venue
- Analytical Chemistry
- Publisher
- American Chemical Society (ACS)
- Published
- 2000-02-16
- Volume
- 72
- Issue
- 6
- Pages
- 1099-1111
- ISSN
- 0003-2700 (ISSN-L)
- 1520-6882
- OpenAlex
- W2058499147
- Cited by
- 213
- References
- 1
- FWCI
- 13.52
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.