The DOI matches its Crossref record; 40 of the 40 references it cites were found in a registry or an index.
Functionalized Organic Thin Film Transistors for Biosensing
Open accessAbstract
The rise of organic bioelectronics efficiently bridges the gap between semiconductor devices and biological systems, leading to flexible, lightweight, and low-cost organic bioelectronic devices suitable for health or body signal monitoring. The introduction of organic semiconductors in the devices can soften the boundaries between microelectronic systems and dynamically active cells and tissues. Therefore, organic bioelectronics has attracted much attention recently due to the unique properties and promising applications. Organic thin film transistors (OTFTs), owing to their inherent capability of amplifying received signals, have emerged as one of the state-of-the-art biosensing platforms. The advantages of organic semiconductors in terms of synthetic freedom, low temperature solution processing, biocompatibility, and mechanical flexibility render OTFTs ideal transducers for wearable electronics, e-skin, and implantable devices. How to realize highly sensitive, selective, rapid, and efficient signal capture and extraction of biological recognition events is the major challenge in the design of biosensors. OTFTs are prone to converting the presence or change of target analytes into specific electrical signals even in complex biological systems. More importantly, OTFT sensors can be conveniently functionalized with chemical or biological modifications and exhibit substantially improved device sensitivity and selectivity as well as other analytical figure of merits, including calibration range, linearity, and accuracy. However, the stability and reproducibility of the organic devices need to be further improved. In this Account, we first introduce the unique features of OTFTs for bioelectronic applications. Two typical OTFT configurations, including organic electrochemical transistor (OECT) and electrolyte gated organic field effect transistor (EGOFET), are highlighted in their sensing applications mainly due to the operation of the devices in electrolytes and the combination of ionic and electronic charge transports in the devices. These devices are potentiometric transducers with low working voltages (<1 V) and high sensitivity, and are thus suitable for wearable applications with low power consumption. Second, the functionalization strategies on channel materials, electrolytes, and gate electrodes based on various modification methods and sensing mechanisms are discussed in sequence. In an OECT- or EGOFET-based biosensor, the device performance is particularly sensitive to the physical properties of the two interfaces, including channel/electrolyte and gate/electrolyte interfaces. Any change in the potential drop or capacitance of either interface can influence the channel current substantially. Therefore, the functionalization of the interfaces is critical to the sensing performance. In particular, when an electrochemically active material is modified on the interfaces, the reaction of the analyte catalyzed by the modified material can influence the interface potential and lead to a channel current response much stronger than that of a conventional electrochemical measurement. So the biosensors are much more sensitive than typical analytical methods due to the signal amplification of the transistors. Third, the processing techniques including screen printing and inkjet printing and the possibility for mass production are discussed. The applications of organic transistors in wearable electronics and healthcare monitoring systems, especially the fabric OECT-based biosensors for noninvasive detection, are presented. It is expected that the versatile organic transistors will enable various compact, flexible and disposable biosensors compatible with wearable electronics.
Overview
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Fully integrated wearable sensor arrays for multiplexed in situ perspiration analysis
Gao, W., Emaminejad, S., Nyein, H. Y. Y., Challa, S., Chen, K., Peck, A., Fahad, H. M., Ota, H., Shiraki, H., Kiriya, D., et al. (2016) · Nature · doi:10.1038/nature16521 · Cited by 5,087
Organic electrochemical transistors
Rivnay, J., Inal, S., Salleo, A., Owens, R. M., Berggren, M., & Malliaras, G. G. (2018) · Nature Reviews Materials · doi:10.1038/natrevmats.2017.86 · Cited by 2,065
Inkjet Printing of Polymers: State of the Art and Future Developments
de Gans, B. ‐., Duineveld, P. C., & Schubert, U. S. (2004) · Advanced Materials · doi:10.1002/adma.200300385 · Cited by 1,906
Organic Thin‐Film Transistors for Chemical and Biological Sensing
Lin, P., & Yan, F. (2012) · Advanced Materials · doi:10.1002/adma.201103334 · Cited by 907
Self-citationOrganic field-effect transistor sensors: a tutorial review
Torsi, L., Magliulo, M., Manoli, K., & Palazzo, G. (2013) · Chemical Society Reviews · doi:10.1039/c3cs60127g · Cited by 825
The Rise of Organic Bioelectronics
Rivnay, J., Owens, R. M., & Malliaras, G. G. (2014) · Chemistry of Materials · doi:10.1021/cm4022003 · Cited by 713
Liao, C., Mak, C., Zhang, M., Chan, H. L. W., & Yan, F. (2015) · Advanced Materials · doi:10.1002/adma.201404378 · Cited by 378
Self-citationLin, P., Luo, X., Hsing, I., & Yan, F. (2011) · Advanced Materials · doi:10.1002/adma.201102017 · Cited by 346
Self-citationTang, H., Yan, F., Lin, P., Xu, J., & Chan, H. L. W. (2011) · Advanced Functional Materials · doi:10.1002/adfm.201002117 · Cited by 310
Self-citationKhodagholy, D., Curto, V. F., Fraser, K. J., Gurfinkel, M., Byrne, R., Diamond, D., Malliaras, G. G., Benito-Lopez, F., & Owens, R. M. (2012) · Journal of Materials Chemistry · doi:10.1039/c2jm15716k · Cited by 303
Cited by
Device integration of electrochemical biosensors
Wu, J., Liu, H., Chen, W., Ma, B., & Ju, H. (2023) · Nature Reviews Bioengineering · doi:10.1038/s44222-023-00032-w · Cited by 895
From Diagnosis to Treatment: Recent Advances in Patient-Friendly Biosensors and Implantable Devices
Li, P., Lee, G.-H., Kim, S. Y., Kwon, S. Y., Kim, H.-R., & Park, S. (2021) · ACS Nano · doi:10.1021/acsnano.0c06688 · Cited by 359
Metadata
- Authors
- Wang, N., Yang, A., Fu, Y., Li, Y., & Yan, F.
- Venue
- Accounts of Chemical Research
- Publisher
- American Chemical Society (ACS)
- Published
- 2019-01-08
- Volume
- 52
- Issue
- 2
- Pages
- 277-287
- ISSN
- 0001-4842 (ISSN-L)
- 1520-4898
- OpenAlex
- W2909027087
- Cited by
- 361
- References
- 40
- FWCI
- 19.50
- Type
- journal article
- Language
- en
- Open access
- green
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: Functionalized Organic Thin Film Transistors for Biosensing. https://app.cochat.ai/papers/10.1021/acs.accounts.8b00448
- The paper
- Wang, N., Yang, A., Fu, Y., Li, Y., & Yan, F. (2019). Functionalized Organic Thin Film Transistors for Biosensing. Accounts of Chemical Research. https://doi.org/10.1021/acs.accounts.8b00448
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.