The DOI matches its Crossref record; 1 of the 1 references it cites were found in a registry or an index.
Highly Sensitive Glucose Biosensors Based on Organic Electrochemical Transistors Using Platinum Gate Electrodes Modified with Enzyme and Nanomaterials
Abstract
Organic electrochemical transistors with glucose oxidase‐modified Pt gate electrodes are successfully used as highly sensitive glucose sensors. The gate electrodes are modified with nanomaterials (multi‐wall carbon nanotubes or Pt nanoparticles) for the first time, which results in a dramatic improvement in the sensitivity of the devices. The detection limit of the device modified with Pt nanoparticles on the gate electrode is about 5 nM, which is three orders of magnitude better than a device without the nanoparticles. The improvement of the device performance can be attributed to the excellent electrocatalytic properties of the nanomaterials and more effective immobilization of enzyme on the gate electrodes. Based on the same principle, many other types of enzyme sensors with high sensitivity and low cost are expected to be realized by modifying the gate electrodes of organic electrochemical transistors with specific enzymes and nanomaterials.
Overview
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Electrochemical Glucose Biosensors
Wang, J. (2008) · Chemical Reviews · doi:10.1021/cr068123a · Cited by 3,498
Cited by
Device integration of electrochemical biosensors
Wu, J., Liu, H., Chen, W., Ma, B., & Ju, H. (2023) · Nature Reviews Bioengineering · doi:10.1038/s44222-023-00032-w · Cited by 895
Flexible Organic Electronics in Biology: Materials and Devices
Liao, C., Zhang, M., Yao, M. Y., Hua, T., Li, L., & Yan, F. (2015) · Advanced Materials · doi:10.1002/adma.201402625 · Cited by 438
Self-citationFunctionalized Organic Thin Film Transistors for Biosensing
Wang, N., Yang, A., Fu, Y., Li, Y., & Yan, F. (2019) · Accounts of Chemical Research · doi:10.1021/acs.accounts.8b00448 · Cited by 361
Self-citationFlexible Electrochemical Biosensors for Health Monitoring
Yang, A., & Yan, F. (2021) · ACS Applied Electronic Materials · doi:10.1021/acsaelm.0c00534 · Cited by 122
Self-citationIntegration of Biomaterials into Sensors Based on Organic Thin‐Film Transistors
Wu, X., Zhou, J., & Huang, J. (2018) · Macromolecular Rapid Communications · doi:10.1002/marc.201800084 · Cited by 28
Metadata
- Authors
- Tang, H., Yan, F., Lin, P., Xu, J., & Chan, H. L. W.
- Venue
- Advanced Functional Materials
- Publisher
- Wiley
- Published
- 2011-04-26
- Volume
- 21
- Issue
- 12
- Pages
- 2264-2272
- ISSN
- 1616-301X (ISSN-L)
- 1616-3028
- OpenAlex
- W2076501420
- Cited by
- 310
- References
- 1
- FWCI
- 9.14
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: Highly Sensitive Glucose Biosensors Based on Organic Electrochemical Transistors Using Platinum Gate Electrodes Modified with Enzyme and Nanomaterials. https://app.cochat.ai/papers/10.1002/adfm.201002117
- The paper
- Tang, H., Yan, F., Lin, P., Xu, J., & Chan, H. L. W. (2011). Highly Sensitive Glucose Biosensors Based on Organic Electrochemical Transistors Using Platinum Gate Electrodes Modified with Enzyme and Nanomaterials. Advanced Functional Materials. https://doi.org/10.1002/adfm.201002117
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.