The DOI matches its Crossref record; 2 of the 2 references it cites were found in a registry or an index.
Organic electrochemical transistor incorporating an ionogel as a solid state electrolyte for lactate sensing
Open accessAbstract
The bulk of the currently available biosensing techniques often require complex liquid handling, and thus suffer from problems associated with leakage and contamination. We demonstrate the use of an organic electrochemical transistor for detection of lactate (an essential analyte in physiological measurements of athlete performance) by integration of a room temperature ionic liquid in a gel-format, as a solid-state electrolyte.
Overview
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Electrochemical Glucose Sensors and Their Applications in Diabetes Management
Heller, A., & Feldman, B. (2008) · Chemical Reviews · doi:10.1021/cr068069y · Cited by 1,707
Cai, X., Yan, J., Chu, H., Wu, M., & Tu, Y. (2010) · Sensors and Actuators B: Chemical · doi:10.1016/j.snb.2009.10.002 · Cited by 71
Cited by
Hammock, M. L., Chortos, A., Tee, B. C. ‐., Tok, J. B. ‐., & Bao, Z. (2013) · Advanced Materials · doi:10.1002/adma.201302240 · Cited by 2,396
Lab-on-Skin: A Review of Flexible and Stretchable Electronics for Wearable Health Monitoring
Liu, Y., Pharr, M., & Salvatore, G. A. (2017) · ACS Nano · doi:10.1021/acsnano.7b04898 · Cited by 1,725
Bio-Integrated Wearable Systems: A Comprehensive Review
Ray, T. R., Choi, J., Bandodkar, A. J., Krishnan, S., Gutruf, P., Tian, L., Ghaffari, R., & Rogers, J. A. (2019) · Chemical Reviews · doi:10.1021/acs.chemrev.8b00573 · Cited by 1,350
Non-invasive wearable electrochemical sensors: a review
Bandodkar, A. J., & Wang, J. (2014) · Trends in Biotechnology · doi:10.1016/j.tibtech.2014.04.005 · Cited by 1,247
Electrolyte‐Gated Transistors for Organic and Printed Electronics
Kim, S. H., Hong, K., Xie, W., Lee, K. H., Zhang, S., Lodge, T. P., & Frisbie, C. D. (2013) · Advanced Materials · doi:10.1002/adma.201202790 · Cited by 957
Metadata
- Authors
- Khodagholy, D., Curto, V. F., Fraser, K. J., Gurfinkel, M., Byrne, R., Diamond, D., Malliaras, G. G., Benito-Lopez, F., & Owens, R. M.
- Venue
- Journal of Materials Chemistry
- Publisher
- Royal Society of Chemistry (RSC)
- Published
- 2012
- Volume
- 22
- Issue
- 10
- Pages
- 4440
- ISSN
- 0959-9428 (ISSN-L)
- 1364-5501
- OpenAlex
- W2055772743
- Cited by
- 303
- References
- 2
- FWCI
- 10.17
- Type
- journal article
- Language
- en
- Open access
- green
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: Organic electrochemical transistor incorporating an ionogel as a solid state electrolyte for lactate sensing. https://app.cochat.ai/papers/10.1039/c2jm15716k
- The paper
- Khodagholy, D., Curto, V. F., Fraser, K. J., Gurfinkel, M., Byrne, R., Diamond, D., Malliaras, G. G., Benito-Lopez, F., & Owens, R. M. (2012). Organic electrochemical transistor incorporating an ionogel as a solid state electrolyte for lactate sensing. Journal of Materials Chemistry. https://doi.org/10.1039/c2jm15716k
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.