Student or educator? Sign up with your school email and get 6 months of Pro free.
Cited by 282

The DOI matches its Crossref record; 32 of the 32 references it cites were found in a registry or an index.

Pressure-Based Biosensor Integrated with a Flexible Pressure Sensor and an Electrochromic Device for Visual Detection

Yu, Zhenzhong, Cai, Guoneng, Liu, Xiaolong, Tang, Dianping·2021·Analytical Chemistry

Abstract

This work demonstrated a pressure-based biosensor integrated with a flexible pressure sensor and an electrochromic device for visual detection. Initially, a sandwich-type immunoreaction for target carcinoembryonic antigen (CEA, as a model analyte) was carried out using the capture antibody (cAb) and platinum nanoparticles-labeled detection antibody (PtNPs-dAb) in a reaction cell. The added hydrogen peroxide (H 2 O 2 ) could be catalyzed by the PtNPs to generate oxygen (O 2 ). In a sealed chamber, the pressure increased with the overflowing O 2 . Meanwhile, a skin-inspired flexible pressure sensor with excellent sensing performance was fabricated to monitor the pressure change in real time. Thus, the electrical signal of the pressure sensor could reveal the target concentration. Moreover, a voltage-regulated electrochromic device based on polyaniline (PANI) and tungsten oxide (WO 3 ) was integrated into the platform to provide a visualized readout. According to the electrical signal of the pressure sensor, the electrochromic device would change its color from green to blue, which also revealed the target concentration and could be observed by the naked eye. Under optimal conditions, the biosensor presented a high sensitivity for CEA in a detectable range of 0.2–50 ng/mL. The limit of detection (LOD) was 94 pg/mL. The selectivity, reproducibility, and accuracy were also satisfying. Furthermore, this immunoassay gives a path for developing visualized biosensors in point-of-care settings.

Overview

The claims and statistics of this paper haven’t been checked yet.

Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.

A few free checks a day · papers already verified open instantly · results are public

Integrity signals

Registry

Crossref · 10.1021/acs.analchem.0c04501

Cites

32 of 32 references verified0 citation errors · 0 not checkable

Statistics

Verification

Claims the paper makes

The claims and statistics of this paper haven’t been checked yet.

Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.

A few free checks a day · papers already verified open instantly · results are public

Self-check

Percentages, sums and reported differences re-computed from the paper’s own numbers.

The self-check needs the paper’s full text.

Citations

Cites

Show all 32 references

Cited by

See all 282

Metadata

Authors
Yu, Z., Cai, G., Liu, X., & Tang, D.
Venue
Analytical Chemistry
Published
2021-01-25
Volume
93
Issue
5
Pages
2916-2925
ISSN
  • 0003-2700 (ISSN-L)
  • 1520-6882
OpenAlex
W3122318373
Cited by
282
References
32
FWCI
15.54
Type
journal article
Language
en
Open access
closed

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review

How to cite

Cite CoChat for the checks on this page, and the paper for its own findings.

This page
CoChat. (2026). Citation check: Pressure-Based Biosensor Integrated with a Flexible Pressure Sensor and an Electrochromic Device for Visual Detection. https://app.cochat.ai/papers/10.1021/acs.analchem.0c04501
The paper
Yu, Z., Cai, G., Liu, X., & Tang, D. (2021). Pressure-Based Biosensor Integrated with a Flexible Pressure Sensor and an Electrochromic Device for Visual Detection. Analytical Chemistry. https://doi.org/10.1021/acs.analchem.0c04501

Data sources

Bibliographic data: Semantic Scholar, OpenAlex, Crossref.

Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).

Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.