The DOI matches its Crossref record; 32 of the 32 references it cites were found in a registry or an index.
Pressure-Based Biosensor Integrated with a Flexible Pressure Sensor and an Electrochromic Device for Visual Detection
Abstract
This work demonstrated a pressure-based biosensor integrated with a flexible pressure sensor and an electrochromic device for visual detection. Initially, a sandwich-type immunoreaction for target carcinoembryonic antigen (CEA, as a model analyte) was carried out using the capture antibody (cAb) and platinum nanoparticles-labeled detection antibody (PtNPs-dAb) in a reaction cell. The added hydrogen peroxide (H 2 O 2 ) could be catalyzed by the PtNPs to generate oxygen (O 2 ). In a sealed chamber, the pressure increased with the overflowing O 2 . Meanwhile, a skin-inspired flexible pressure sensor with excellent sensing performance was fabricated to monitor the pressure change in real time. Thus, the electrical signal of the pressure sensor could reveal the target concentration. Moreover, a voltage-regulated electrochromic device based on polyaniline (PANI) and tungsten oxide (WO 3 ) was integrated into the platform to provide a visualized readout. According to the electrical signal of the pressure sensor, the electrochromic device would change its color from green to blue, which also revealed the target concentration and could be observed by the naked eye. Under optimal conditions, the biosensor presented a high sensitivity for CEA in a detectable range of 0.2–50 ng/mL. The limit of detection (LOD) was 94 pg/mL. The selectivity, reproducibility, and accuracy were also satisfying. Furthermore, this immunoassay gives a path for developing visualized biosensors in point-of-care settings.
Overview
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Crystallographically Oriented Mesoporous WO3 Films: Synthesis, Characterization, and Applications
Santato, C., Odziemkowski, M., Ulmann, M., & Augustynski, J. (2001) · Journal of the American Chemical Society · doi:10.1021/ja011315x · Cited by 1,076
Hybrid Materials and Polymer Electrolytes for Electrochromic Device Applications
Thakur, V. K., Ding, G., Ma, J., Lee, P. S., & Lu, X. (2012) · Advanced Materials · doi:10.1002/adma.201200213 · Cited by 821
Nanoparticle-Based Immunochemical Biosensors and Assays: Recent Advances and Challenges
Farka, Z., Juřík, T., Kovář, D., Trnková, L., & Skládal, P. (2017) · Chemical Reviews · doi:10.1021/acs.chemrev.7b00037 · Cited by 694
Emerging Technologies of Flexible Pressure Sensors: Materials, Modeling, Devices, and Manufacturing
Huang, Y., Fan, X., Chen, S., & Zhao, N. (2019) · Advanced Functional Materials · doi:10.1002/adfm.201808509 · Cited by 543
Shrivastava, S., Trung, T. Q., & Lee, N.-E. (2020) · Chemical Society Reviews · doi:10.1039/c9cs00319c · Cited by 497
Chang, J., Wang, X., Wang, J., Li, H., & Li, F. (2019) · Analytical Chemistry · doi:10.1021/acs.analchem.8b05599 · Cited by 469
Mimicking Human and Biological Skins for Multifunctional Skin Electronics
Lee, Y., Park, J., Choe, A., Cho, S., Kim, J., & Ko, H. (2020) · Advanced Functional Materials · doi:10.1002/adfm.201904523 · Cited by 465
Park, H., Jeong, Y. R., Yun, J., Hong, S. Y., Jin, S., Lee, S.-J., Zi, G., & Ha, J. S. (2015) · ACS Nano · doi:10.1021/acsnano.5b03510 · Cited by 426
Raman spectroscopy of polyaniline and oligoaniline thin films
Trchová, M., Morávková, Z., Bláha, M., & Stejskal, J. (2014) · Electrochimica Acta · doi:10.1016/j.electacta.2013.10.133 · Cited by 346
Recent advances in biosensor for detection of lung cancer biomarkers
Yang, G., Xiao, Z., Tang, C., Deng, Y., Huang, H., & He, Z. (2019) · Biosensors and Bioelectronics · doi:10.1016/j.bios.2019.111416 · Cited by 330
Cited by
CRISPR-Driven Biosensors: A New Frontier in Rapid and Accurate Disease Detection
Razavi, Z., Soltani, M., Souri, M., & Pazoki-Toroudi, H. (2026) · Critical Reviews in Analytical Chemistry · doi:10.1080/10408347.2024.2400267 · Cited by 45
Metadata
- Authors
- Yu, Z., Cai, G., Liu, X., & Tang, D.
- Venue
- Analytical Chemistry
- Publisher
- American Chemical Society (ACS)
- Published
- 2021-01-25
- Volume
- 93
- Issue
- 5
- Pages
- 2916-2925
- ISSN
- 0003-2700 (ISSN-L)
- 1520-6882
- OpenAlex
- W3122318373
- Cited by
- 282
- References
- 32
- FWCI
- 15.54
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: Pressure-Based Biosensor Integrated with a Flexible Pressure Sensor and an Electrochromic Device for Visual Detection. https://app.cochat.ai/papers/10.1021/acs.analchem.0c04501
- The paper
- Yu, Z., Cai, G., Liu, X., & Tang, D. (2021). Pressure-Based Biosensor Integrated with a Flexible Pressure Sensor and an Electrochromic Device for Visual Detection. Analytical Chemistry. https://doi.org/10.1021/acs.analchem.0c04501
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.