CoChat

Reverse Transcription Recombinase Polymerase Amplification Coupled with CRISPR-Cas12a for Facile and Highly Sensitive Colorimetric SARS-CoV-2 Detection

Zhang, Wei S., Pan, Jianbin, Li, Feng, Zhu, Min, Xu, Mengting, Zhu, Hongyan, Yu, Yanyan, Su, Gaoxing · 2021 · Analytical Chemistry
Cited by 252

The DOI matches its Crossref record; 47 of the 47 references it cites were found in a registry or an index.

Abstract

The outbreak of the pandemic caused by the severe acute respiratory syndrome coronavirus-2 (SARS-CoV-2) calls for an urgent unmet need for developing a facial and cost-effective detection method. The requirement of well-trained personnel and sophisticated instrument of current primary mean (reverse transcription polymerase chain reaction, RT-PCR) may hinder the practical application worldwide. In this regard, a reverse transcription recombinase polymerase amplification (RT-RPA) coupled with CRISPR-Cas12a colorimetric assay is proposed for the SARS-CoV-2 detection. The methodology we have described herein utilizes DNA-modified gold nanoparticles (AuNPs) as a universal colorimetric readout and can specifically target ORF1ab and N regions of the SARS-CoV-2 genome. After the virus genome is amplified through RT-RPA, the resulting abundant dsDNA will bind and activate Cas12a. Under trans-cleavage degradation, the capped DNA substrate will be hydrolyzed gradually from AuNPs, demonstrating a change in the surface plasmon resonance (SPR), which can be facially monitored by UV-vis absorbance spectroscopy and naked eye observation. The high amplification efficiency from RT-RPA and Cas12a trans-cleavage process bring the sensitivity of our method to 1 copy of viral genome sequence per test. Notably, under the dual variations inspecting from the isothermal amplification and Cas12a activation process, the false positive events from other beta coronavirus members can be effectively avoided and thus significantly improve the specificity. Furthermore, the reliability of this colorimetric assay is validated by standard clinical samples from the hospital laboratory department. Through integration of the inherently high sensitivity and specificity from an RPA-coupled Cas12a system with the intrinsic simplicity of AuNP-based colorimetric assay, our method increases the practical testing availability of SARS-CoV-2.

Overview

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Integrity signals

Registry

Crossref · 10.1021/acs.analchem.1c00013

Cites

47 of 47 references verified0 citation errors · 0 not checkable

Statistics

Verification

Claims the paper makes

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Self-check

Percentages, sums and reported differences re-computed from the paper’s own numbers.

The self-check needs the paper’s full text.

Citations

Cites

Show all 47 references

Cited by

Metadata

Authors
Zhang, W. S., Pan, J., Li, F., Zhu, M., Xu, M., Zhu, H., Yu, Y., & Su, G.
Venue
Analytical Chemistry
Published
2021-02-11
Volume
93
Issue
8
Pages
4126-4133
ISSN
  • 0003-2700 (ISSN-L)
  • 1520-6882
OpenAlex
W3126789423
Cited by
252
References
47
FWCI
14.96
Type
journal article
Language
en
Open access
closed

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review

Data sources

Bibliographic data: Semantic Scholar, OpenAlex, Crossref.

Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).

Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.