CoChat

ACEstat: A DIY Guide to Unlocking the Potential of Integrated Circuit Potentiostats for Open-Source Electrochemical Analysis

The DOI matches its Crossref record; 34 of the 34 references it cites were found in a registry or an index.

Abstract

Miniaturization of analytical instrumentation is paramount to enabling convenient in-field sensing. The recent thrust in potentiostat miniaturization for electrochemical sensing and general use has led to the development of commercial application specific integrated circuits (ASICs) that pack all the power of a benchtop instrument into one 5 mm × 5 mm chip. While the capabilities of these integrated circuits far exceed those of open-source potentiostats in the literature, the activation barrier for their implementation requires extensive electrical and software engineering expertise to overcome. In order to more rapidly bring the utility of ASIC potentiostats to researchers, we present a low size, weight, power, and cost (Low SWaP-C) Army Corps of Engineers potentiostat (ACEstat) based on the widely available ADuCM355 offered by Analog Devices. This potentiostat is a streamlined and fully programmable device that leverages industry-leading integrated hardware to perform electrochemical measurements such as cyclic voltammetry, pulse voltammetry, and electrochemical impedance spectroscopy. The ACEstat enables control over a wide range of test parameters and displays results through an intuitive, open-source graphical user interface available on mobile devices and computers. In this report, we present an approachable, do-it-yourself guide to unlocking the capabilities of this integrated circuit potentiostat by outlining the fabrication and programming details necessary to facilitate electroanalysis. Furthermore, we demonstrate the practicality of this device by detecting 2,4,6-trinitrotoluene (TNT) in water at sub-mg/L detection limits, highlighting its potential for in-field use.

Overview

Integrity signals

Registry

Crossref · 10.1021/acs.analchem.1c04226

Cites

34 of 34 references verified0 citation errors · 0 not checkable

Statistics

Recomputing p-values needs the paper’s full text.

Verification

Claims the paper makes

This paper’s full text isn’t openly available, so its claims and self-check weren’t run. The registry and citation checks still apply.

Citations

Cites

Show all 34 references

Research works printed but not linked: 4

  1. 10.1021/acsapm.1c00575 · DOI
  2. Hwang H., 2007, Electrochemical Analysis
  3. Glasscott, M. W. Nanodroplet-Mediated Electrodeposition: Fundamental Principles and Applications to Nanomaterial Synthesis. Ph.D. Thesis, The University of North Carolina at Chapel Hill, Chapel Hill, NC, 2021.
  4. 10.1021/acsomega.0c04776 · DOI

Cited by

See all 34

Metadata

Authors
Brown, E. W., Glasscott, M. W., Conley, K., Barr, J., Ray, J. D., Moores, L. C., & Netchaev, A.
Affiliations
U.S. Army Engineer Research and Development Center (US)
Corresponding author
Netchaev, Anton
Venue
Analytical Chemistry
Published
2022-03-08
Volume
94
Issue
12
Pages
4906-4912
ISSN
  • 0003-2700 (ISSN-L)
  • 1520-6882
OpenAlex
W4220876512
Cited by
34
References
33
Citations by year
2026: 5 · 2025: 11 · 2024: 10 · 2023: 6 · 2022: 2
FWCI
2.60
Type
journal article
Language
en
Open access
closed
Locations
  • Analytical Chemistry (publishedVersion)
  • PubMed (publishedVersion)
Topics
  • Physical Sciences › Chemistry › Electrochemistry › Electrochemical Analysis and Applications
  • Physical Sciences › Chemistry › Analytical Chemistry › Electrochemical sensors and biosensors
  • Physical Sciences › Chemistry › Analytical Chemistry › Analytical Chemistry and Sensors
Keywords
potentiostat, application-specific integrated circuits, open-source hardware, cyclic voltammetry, pulse voltammetry, electrochemical impedance spectroscopy, explosives detection, graphical user interface
MeSH terms
Electricity, Electrodes, Electrochemical Techniques, Dielectric Spectroscopy

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review

How to cite

Cite CoChat for the checks on this page, and the paper for its own findings.

This page
CoChat. (2026). Citation check: ACEstat: A DIY Guide to Unlocking the Potential of Integrated Circuit Potentiostats for Open-Source Electrochemical Analysis. https://app.cochat.ai/papers/10.1021/acs.analchem.1c04226
The paper
Brown, E. W., Glasscott, M. W., Conley, K., Barr, J., Ray, J. D., Moores, L. C., & Netchaev, A. (2022). ACEstat: A DIY Guide to Unlocking the Potential of Integrated Circuit Potentiostats for Open-Source Electrochemical Analysis. Analytical Chemistry. https://doi.org/10.1021/acs.analchem.1c04226

Data sources

Bibliographic data: Semantic Scholar, OpenAlex, Crossref.

Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).

Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.