CoChat

Parallelized Acquisition of Orbitrap and Astral Analyzers Enables High-Throughput Quantitative Analysis

Open access
Stewart, Hamish I., Grinfeld, Dmitry, Giannakopulos, Anastassios, Petzoldt, Johannes, Shanley, Toby, Garland, Matthew, Denisov, Eduard, Peterson, Amelia C., Damoc, Eugen, Zeller, Martin, Arrey, Tabiwang N., Pashkova, Anna, Renuse, Santosh, Hakimi, Amirmansoor, Kühn, Andreas, Biel, Matthias, Kreutzmann, Arne, Hagedorn, Bernd, Colonius, Immo, Schütz, Adrian, Stefes, Arne, Dwivedi, Ankit, Mourad, Daniel, Hoek, Max, Reitemeier, Bastian, Cochems, Philipp, Kholomeev, Alexander, Ostermann, Robert, Quiring, Gregor, Ochmann, Maximilian, Möhring, Sascha, Wagner, Alexander, Petker, André, Kanngiesser, Sebastian, Wiedemeyer, Michael, Balschun, Wilko, Hermanson, Daniel, Zabrouskov, Vlad, Makarov, Alexander A., Hock, Christian · 2023 · Analytical Chemistry
Cited by 218

The DOI matches its Crossref record; 7 of the 7 references it cites were found in a registry or an index.

Abstract

The growing trend toward high-throughput proteomics demands rapid liquid chromatography-mass spectrometry (LC-MS) cycles that limit the available time to gather the large numbers of MS/MS fragmentation spectra required for identification. Orbitrap analyzers scale performance with acquisition time and necessarily sacrifice sensitivity and resolving power to deliver higher acquisition rates. We developed a new mass spectrometer that combines a mass-resolving quadrupole, the Orbitrap, and the novel Asymmetric Track Lossless (Astral) analyzer. The new hybrid instrument enables faster acquisition of high-resolution accurate mass (HRAM) MS/MS spectra compared with state-of-the-art mass spectrometers. Accordingly, new proteomics methods were developed that leverage the strengths of each HRAM analyzer, whereby the Orbitrap analyzer performs full scans with a high dynamic range and resolution, synchronized with the Astral analyzer's acquisition of fast and sensitive HRAM MS/MS scans. Substantial improvements are demonstrated over previous methods using current state-of-the-art mass spectrometers.

Overview

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Integrity signals

Registry

Crossref · 10.1021/acs.analchem.3c02856

Cites

7 of 7 references verified0 citation errors · 0 not checkable

Statistics

Verification

Claims the paper makes

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Self-check

Percentages, sums and reported differences re-computed from the paper’s own numbers.

The self-check needs the paper’s full text.

Citations

Cites

Show all 7 references

Cited by

Metadata

Authors
Stewart, H. I., Grinfeld, D., Giannakopulos, A., Petzoldt, J., Shanley, T., Garland, M., Denisov, E., Peterson, A. C., Damoc, E., Zeller, M., Arrey, T. N., Pashkova, A., Renuse, S., Hakimi, A., Kühn, A., Biel, M., Kreutzmann, A., Hagedorn, B., Colonius, I., Schütz, A., Stefes, A., Dwivedi, A., Mourad, D., Hoek, M., Reitemeier, B., Cochems, P., Kholomeev, A., Ostermann, R., Quiring, G., Ochmann, M., Möhring, S., Wagner, A., Petker, A., Kanngiesser, S., Wiedemeyer, M., Balschun, W., Hermanson, D., Zabrouskov, V., Makarov, A. A., & Hock, C.
Venue
Analytical Chemistry
Published
2023-10-10
Volume
95
Issue
42
Pages
15656-15664
ISSN
  • 0003-2700 (ISSN-L)
  • 1520-6882
OpenAlex
W4387493976
Cited by
218
References
7
FWCI
19.48
Type
journal article
Language
en
Open access
hybrid

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review

Data sources

Bibliographic data: Semantic Scholar, OpenAlex, Crossref.

Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).

Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.