CoChat

Detection and Direct Readout of Drugs in Human Urine Using Dynamic Surface-Enhanced Raman Spectroscopy and Support Vector Machines

Dong, Ronglu, Weng, Shizhuang, Yang, Liangbao, Liu, Jinhuai · 2015 · Analytical Chemistry

The DOI matches its Crossref record; 37 of the 38 references it cites were found in a registry or an index.

Abstract

A new, novel, rapid method to detect and direct readout of drugs in human urine has been developed using dynamic surface-enhanced Raman spectroscopy (D-SERS) with portable Raman spectrometer on gold nanorods (GNRs) and a classification algorithm called support vector machines (SVM). The high-performance GNRs can generate gigantic enhancement and the SERS signals obtained using D-SERS on it have high reproducibility. On the basis of this feature of D-SERS, we have obtained SERS spectra of urine and urine containing methamphetamine (MAMP). SVM model was built using these data for fast identified and visual results. This general method was successfully applied to the detection of 3, 4-methylenedioxy methamphetamine (MDMA) in human urine. To verify the accuracy of the model, drug addicts' urine containing MAMP were detected and identified correctly and rapidly with accuracy more than 90%. The detection results were displayed directly without analysis of their SERS spectra manually. Compared with the conventional method in lab, the method only needs a 2 μL sample volume and takes no more than 2 min on the portable Raman spectrometer. It is anticipated that this method will enable rapid, convenient detection of drugs on site for the police.

Overview

Integrity signals

Registry

Crossref · 10.1021/acs.analchem.5b00137

Cites

37 of 37 references verified0 citation errors · 0 not checkable

Statistics

Recomputing p-values needs the paper’s full text.

Verification

Claims the paper makes

This paper’s full text isn’t openly available, so its claims and self-check weren’t run. The registry and citation checks still apply.

Citations

Cites

Show all 37 references

Research works printed but not linked: 2

  1. Wang X. M., 2012, Trop. J. Pharm. Res., 11, 621
  2. Li S.-X., 2013, J. Biomed. Opt, 18, 0270081

Cited by

See all 198

Metadata

Authors
Dong, R., Weng, S., Yang, L., & Liu, J.
Affiliations
  • University of Science and Technology of China (CN)
  • Chinese Academy of Sciences (CN)
Corresponding author
Yang, Liangbao
Venue
Analytical Chemistry
Published
2015-02-10
Volume
87
Issue
5
Pages
2937-2944
ISSN
  • 0003-2700 (ISSN-L)
  • 1520-6882
OpenAlex
W2334757790
Cited by
195
References
38
Citations by year
2026: 7 · 2025: 15 · 2024: 19 · 2023: 19 · 2022: 26 · 2021: 13 · 2020: 21 · 2019: 22 · 2018: 18 · 2017: 12 · 2016: 18 · 2015: 5
FWCI
5.78
Type
journal article
Language
en
Open access
closed
Locations
  • Analytical Chemistry (publishedVersion)
  • PubMed (publishedVersion)
Funders
Ministry of Science and Technology of the People's Republic of China (2011CB933700, 2011YQ0301241001, 2011YQ0301241101)
Topics
  • Physical Sciences › Materials Science › Electronic, Optical and Magnetic Materials › Gold and Silver Nanoparticles Synthesis and Applications
  • Life Sciences › Biochemistry, Genetics and Molecular Biology › Biophysics › Spectroscopy Techniques in Biomedical and Chemical Research
  • Health Sciences › Medicine › Infectious Diseases › SARS-CoV-2 detection and testing
Keywords
urine drug testing, gold nanorods, support vector machine, methamphetamine, MDMA, portable Raman spectrometer, drug screening, drug addicts, on-site drug testing
MeSH terms
Algorithms, Dimethylnitrosamine, Gold, Humans, Pyrimidines, Silver, Spectrum Analysis, Raman, Surface Properties, Surface Plasmon Resonance, Nanotubes, Metal Nanoparticles, Support Vector Machine

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review

How to cite

Cite CoChat for the checks on this page, and the paper for its own findings.

This page
CoChat. (2026). Citation check: Detection and Direct Readout of Drugs in Human Urine Using Dynamic Surface-Enhanced Raman Spectroscopy and Support Vector Machines. https://app.cochat.ai/papers/10.1021/acs.analchem.5b00137
The paper
Dong, R., Weng, S., Yang, L., & Liu, J. (2015). Detection and Direct Readout of Drugs in Human Urine Using Dynamic Surface-Enhanced Raman Spectroscopy and Support Vector Machines. Analytical Chemistry. https://doi.org/10.1021/acs.analchem.5b00137

Data sources

Bibliographic data: Semantic Scholar, OpenAlex, Crossref.

Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).

Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.