The DOI matches its Crossref record; 23 of the 23 references it cites were found in a registry or an index.
Electrochemical Aptasensor of Cardiac Troponin I for the Early Diagnosis of Acute Myocardial Infarction
Abstract
Cardiac troponin I (cTnI) is well-known as a promising biomarker for the early diagnosis of acute myocardial infarction (AMI). In this work, single-stranded DNA aptamers against cTnI were identified by the Systematic Evolution of Ligands by Exponential enrichment (SELEX) method. The aptamer candidates exhibited a high selectivity and sensitivity toward both cTnI and the cardiac Troponin complex. The binding affinities of each aptamer were evaluated based on their dissociation constants (Kd) by surface plasma resonance. The Tro4 aptamer that had the highest binding capacity to cTnI showed a very low Kd value (270 pM) compared with that of a cTnI antibody (20.8 nM). Furthermore, we designed a new electrochemical aptasensor based on square wave voltammetry using ferrocene-modified silica nanoparticles. The developed aptasensor demonstrated an excellent analytical performance for cTnI with a wide linear range of 1-10 000 pM in a buffer and a detection limit of 1.0 pM (24 pg/mL; S/N = 3), which was noticeably lower than the cutoff values (70-400 pg/mL). The specificity of the aptamers was also examined using nontarget proteins, demonstrating that the proposed sensor responded to only cTnI. In addition, cTnI was successfully detected in a human serum albumin solution. On the basis of the calibration curve that was constructed, the concentrations of cTnI in a solution supplemented with human serum were effectively measured. The calculated values correlated well with the actual concentrations of cTnI. It is anticipated that the highly sensitive and selective aptasensor for cTnI could be readily applicable for the accurate diagnosis of AMI.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Tuerk, C., & Gold, L. (1990) · Science · doi:10.1126/science.2200121 · Cited by 10,405
In vitro selection of RNA molecules that bind specific ligands
Ellington, A. D., & Szostak, J. W. (1990) · Nature · doi:10.1038/346818a0 · Cited by 9,812
WRITING COMMITTEE MEMBERS*, O’Gara, P. T., Kushner, F. G., Ascheim, D. D., Casey, D. E., Chung, M. K., de Lemos, J. A., Ettinger, S. M., Fang, J. C., Fesmire, F. M., et al. (2013) · Circulation · doi:10.1161/cir.0b013e3182742cf6 · Cited by 4,725
Drummond, T. G., Hill, M. G., & Barton, J. K. (2003) · Nature Biotechnology · doi:10.1038/nbt873 · Cited by 2,214
Aptamers: An Emerging Class of Molecules That Rival Antibodies in Diagnostics
Jayasena, S. D. (1999) · Clinical Chemistry · doi:10.1093/clinchem/45.9.1628 · Cited by 2,144
Applications of Aptamers as Sensors
Cho, E. J., Lee, J.-W., & Ellington, A. D. (2009) · Annual Review of Analytical Chemistry · doi:10.1146/annurev.anchem.1.031207.112851 · Cited by 788
Self-citationAptamer in Bioanalytical Applications
Iliuk, A. B., Hu, L., & Tao, W. A. (2011) · Analytical Chemistry · doi:10.1021/ac201057w · Cited by 762
Label-Free Protein Biosensor Based on Aptamer-Modified Carbon Nanotube Field-Effect Transistors
Maehashi, K., Katsura, T., Kerman, K., Takamura, Y., Matsumoto, K., & Tamiya, E. (2007) · Analytical Chemistry · doi:10.1021/ac060830g · Cited by 660
Cardiac-specific troponin-l radioimmunoassay in the diagnosis of acute myocardial infarction
Cummins, B., Auckland, M. L., & Cummins, P. (1987) · American Heart Journal · doi:10.1016/0002-8703(87)90645-4 · Cited by 429
Bodor, G. S., Porter, S., Landt, Y., & Ladenson, J. H. (1992) · Clinical Chemistry · doi:10.1093/clinchem/38.11.2203 · Cited by 425
Aptamer-Based Detection of Plasma Proteins by an Electrochemical Assay Coupled to Magnetic Beads
Centi, S., Tombelli, S., Minunni, M., & Mascini, M. (2007) · Analytical Chemistry · doi:10.1021/ac061879p · Cited by 409
Differential diagnosis of elevated troponins
Korff, S., Katus, H. A., & Giannitsis, E. (2006) · Heart · doi:10.1136/hrt.2005.071282 · Cited by 388
Aptamers as molecular recognition elements for electrical nanobiosensors
Lee, J.-O., So, H.-M., Jeon, E.-K., Chang, H., Won, K., & Kim, Y. H. (2008) · Analytical and Bioanalytical Chemistry · doi:10.1007/s00216-007-1643-y · Cited by 277
Self-citationImproved detection of minor ischemic myocardial injury with measurement of serum cardiac troponin I
Apple, F. S., Falahati, A., Paulsen, P. R., Miller, E. A., & Sharkey, S. W. (1997) · Clinical Chemistry · doi:10.1093/clinchem/43.11.2047 · Cited by 190
Kong, T., Su, R., Zhang, B., Zhang, Q., & Cheng, G. (2012) · Biosensors and Bioelectronics · doi:10.1016/j.bios.2012.02.019 · Cited by 136
A simple and direct electrochemical detection of interferon-γ using its RNA and DNA aptamers
Min, K., Cho, M., Han, S.-Y., Shim, Y., Ku, J., & Ban, C. (2008) · Biosensors and Bioelectronics · doi:10.1016/j.bios.2008.02.021 · Cited by 111
Self-citationRecent Progress in Ferrocene-Modified Thin Films and Nanoparticles for Biosensors
Takahashi, S., & Anzai, J. (2013) · Materials · doi:10.3390/ma6125742 · Cited by 103
Zhuo, Y., Chai, Y.-Q., Yuan, R., Mao, L., Yuan, Y., & Han, J. (2011) · Biosensors and Bioelectronics · doi:10.1016/j.bios.2011.02.043 · Cited by 87
Rapid Measurement of Cardiac Markers on Stratus CS
Altinier, S., Mion, M. M., Cappelletti, A., Zaninotto, M., & Plebani, M. (2000) · Clinical Chemistry · doi:10.1093/clinchem/46.7.991 · Cited by 53
Budny, A., Novák, F., Plumeré, N., Schetter, B., Speiser, B., Straub, D., Mayer, H. A., & Reginek, M. (2006) · Langmuir · doi:10.1021/la061107o · Cited by 49
Myoglobin and creatine kinase in acute myocardial infarction.
McComb, J., McMaster, E. A., MacKenzie, G., et al. (1984) · Heart · doi:10.1136/hrt.51.2.189 · Cited by 49
Noise spectroscopy as an equilibrium analysis tool for highly sensitive electrical biosensing
Guo, Q., Kong, T., Su, R., Zhang, Q., & Cheng, G. (2012) · Applied Physics Letters · doi:10.1063/1.4748931 · Cited by 34
Chapelle, J.-P., Aldenhoff, M.-C., Piérard, L., & GIELEN, J. E. (2000) · Clinical Chemistry · doi:10.1093/clinchem/46.11.1864 · Cited by 13
Cited by
Chang, J., Wang, X., Wang, J., Li, H., & Li, F. (2019) · Analytical Chemistry · doi:10.1021/acs.analchem.8b05599 · Cited by 469
Nucleic Acid Biosensors: Recent Advances and Perspectives
Du, Y., & Dong, S. (2017) · Analytical Chemistry · doi:10.1021/acs.analchem.6b04190 · Cited by 429
Arduini, F., Micheli, L., Moscone, D., Palleschi, G., Piermarini, S., Ricci, F., & Volpe, G. (2016) · TrAC Trends in Analytical Chemistry · doi:10.1016/j.trac.2016.01.032 · Cited by 395
Li, S., Zhang, H., Zhu, M., Kuang, Z., Li, X., Xu, F., Miao, S., Zhang, Z., Lou, X., Li, H., et al. (2023) · Chemical Reviews · doi:10.1021/acs.chemrev.1c00759 · Cited by 309
Metadata
- Authors
- Jo, H., Gu, H., Jeon, W., Youn, H., Her, J., Kim, S.-K., Lee, J., Shin, J. H., & Ban, C.
- Venue
- Analytical Chemistry
- Publisher
- American Chemical Society (ACS)
- Published
- 2015-09-16
- Volume
- 87
- Issue
- 19
- Pages
- 9869-9875
- ISSN
- 0003-2700 (ISSN-L)
- 1520-6882
- OpenAlex
- W2413857966
- Cited by
- 270
- References
- 23
- FWCI
- 7.08
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.