Student or educator? Sign up with your school email and get 6 months of Pro free.
Cited by 158

The DOI matches its Crossref record; 2 of the 2 references it cites were found in a registry or an index.

Aptamer/Graphene Quantum Dots Nanocomposite Capped Fluorescent Mesoporous Silica Nanoparticles for Intracellular Drug Delivery and Real-Time Monitoring of Drug Release

Zheng, Fen-Fen, Zhang, Peng-Hui, Xi, Yu, Chen, Jing-Jia, Li, Ling-Ling, Zhu, Jun-Jie·2015·Analytical Chemistry

Abstract

Great challenges in investigating the release of drug in complex cellular microenvironments necessitate the development of stimuli-responsive drug delivery systems with real-time monitoring capability. In this work, a smart drug nanocarrier based on fluorescence resonance energy transfer (FRET) is fabricated by capping graphene quantum dots (GQDs, the acceptor) onto fluorescent mesoporous silica nanoparticles (FMSNs, the donor) via ATP aptamer for real-time monitoring of ATP-triggered drug release. Under extracellular conditions, the fluorescence of FMSNs remains in the "off" state in the low ATP level which is unable to trigger the release of drug. Once specifically recognized and internalized into the target tumor cells by AS1411 aptamer, in the ATP-rich cytoplasm, the conformation switch of the ATP aptamer causes the shedding of the GQDs from the nanocarriers, leading to the release of the loaded drugs and consequently severe cytotoxicity. Simultaneously, the fluorescence of FMSNs turns "on" along with the dissociation of GQDs, which allows real-time monitoring of the release of drug from the pores. Such a drug delivery system features high specificity of dual-target recognition with AS1411 and ATP aptamer as well as high sensitivity of the FRET-based monitoring strategy. Thus, the proposed multifunctional ATP triggered FRET-nanocarriers will find potential applications for versatile drug-release monitoring, efficient drug transport, and targeted cancer therapeutics.

Overview

The claims and statistics of this paper haven’t been checked yet.

Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.

A few free checks a day · papers already verified open instantly · results are public

Integrity signals

Registry

Crossref · 10.1021/acs.analchem.5b03131

Cites

2 of 2 references verified0 citation errors · 0 not checkable

Statistics

Verification

Claims the paper makes

The claims and statistics of this paper haven’t been checked yet.

Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.

A few free checks a day · papers already verified open instantly · results are public

Self-check

Percentages, sums and reported differences re-computed from the paper’s own numbers.

The self-check needs the paper’s full text.

Citations

Cites

Show all 2 references

Cited by

See all 158

Metadata

Authors
Zheng, F.-F., Zhang, P.-H., Xi, Y., Chen, J.-J., Li, L.-L., & Zhu, J.-J.
Venue
Analytical Chemistry
Published
2015-11-10
Volume
87
Issue
23
Pages
11739-11745
ISSN
  • 0003-2700 (ISSN-L)
  • 1520-6882
OpenAlex
W1949277921
Cited by
158
References
2
FWCI
6.30
Type
journal article
Language
en
Open access
closed

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review

How to cite

Cite CoChat for the checks on this page, and the paper for its own findings.

This page
CoChat. (2026). Citation check: Aptamer/Graphene Quantum Dots Nanocomposite Capped Fluorescent Mesoporous Silica Nanoparticles for Intracellular Drug Delivery and Real-Time Monitoring of Drug Release. https://app.cochat.ai/papers/10.1021/acs.analchem.5b03131
The paper
Zheng, F.-F., Zhang, P.-H., Xi, Y., Chen, J.-J., Li, L.-L., & Zhu, J.-J. (2015). Aptamer/Graphene Quantum Dots Nanocomposite Capped Fluorescent Mesoporous Silica Nanoparticles for Intracellular Drug Delivery and Real-Time Monitoring of Drug Release. Analytical Chemistry. https://doi.org/10.1021/acs.analchem.5b03131

Data sources

Bibliographic data: Semantic Scholar, OpenAlex, Crossref.

Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).

Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.