The DOI matches its Crossref record.
Enhanced Photoelectrochemical Immunosensing Platform Based on CdSeTe@CdS:Mn Core–Shell Quantum Dots-Sensitized TiO2 Amplified by CuS Nanocrystals Conjugated Signal Antibodies
Abstract
A new, ultrasensitive photoelectrochemical immunosensing platform was established on the basis of CdSeTe@CdS:Mn core-shell quantum dots-sensitized TiO2 coupled with signal amplification of CuS nanocrystals conjugated signal antibodies. In this proposal, carcinoembryonic antigen (CEA, Ag) was selected as an example of target analyte to show the analytical performances of the platform. Specifically, TiO2-modified electrode was first assembled with CdSeTe alloyed quantum dots (AQDs) via electrostatic adsorption assisted by oppositely charged polyelectrolyte, and then further deposited with CdS:Mn shells on the surface of CdSeTe AQDs via successive ionic layer adsorption and reaction strategy, forming TiO2/CdSeTe@CdS:Mn sensitization structure, which was used as photoelectrochemical matrix to immobilize capture CEA antibodies (Ab1); signal CEA antibodies (Ab2) were labeled with CuS nanocrystals (NCs) to form Ab2-CuS conjugates, which were employed as signal amplification elements when specific immunoreaction occurred. The ultrahigh sensitivity of this immunoassay resulted from the following two aspects. Before detection of target Ag, the TiO2/CdSeTe@CdS:Mn sensitization structure could adequately harvest the exciting light with different bands, evidently expedite the electron transfer, and effectively depress the charge recombination, resulting in noticeably increased photocurrent. When target Ag existed, the Ab2-CuS conjugates could dramatically decrease the photocurrent due to competitive absorption of exciting light and consumption of electron donor for CuS NCs coupled with steric hindrance of Ab2 molecules. The fabricated photoelectrochemical immunosensor showed a low limit of detection of 0.16 pg/mL and a wide linear range from 0.5 pg/mL to 100 ng/mL for CEA detection, and it also exhibited good specificity, reproducibility, and stability.
Overview
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cited by
Shu, J., & Tang, D. (2020) · Analytical Chemistry · doi:10.1021/acs.analchem.9b04199 · Cited by 976
Recent Advances in Electrochemical Immunosensors
Wen, W., Yan, X., Zhu, C., Du, D., & Lin, Y. (2017) · Analytical Chemistry · doi:10.1021/acs.analchem.6b04281 · Cited by 313
Self-citationHighly Sensitive and Multiplexed Protein Measurements
Cohen, L., & Walt, D. R. (2019) · Chemical Reviews · doi:10.1021/acs.chemrev.8b00257 · Cited by 294
Dong, T., Matos Pires, N. M., Yang, Z., & Jiang, Z. (2023) · Advanced Science · doi:10.1002/advs.202205429 · Cited by 104
Metadata
- Authors
- Fan, G.-C., Zhu, H., Du, D., Zhang, J.-R., Zhu, J.-J., & Lin, Y.
- Venue
- Analytical Chemistry
- Publisher
- American Chemical Society (ACS)
- Published
- 2016-03-04
- Volume
- 88
- Issue
- 6
- Pages
- 3392-3399
- ISSN
- 0003-2700 (ISSN-L)
- 1520-6882
- OpenAlex
- W2284800182
- Cited by
- 185
- References
- 0
- FWCI
- 16.85
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: Enhanced Photoelectrochemical Immunosensing Platform Based on CdSeTe@CdS:Mn Core–Shell Quantum Dots-Sensitized TiO2 Amplified by CuS Nanocrystals Conjugated Signal Antibodies. https://app.cochat.ai/papers/10.1021/acs.analchem.6b00144
- The paper
- Fan, G.-C., Zhu, H., Du, D., Zhang, J.-R., Zhu, J.-J., & Lin, Y. (2016). Enhanced Photoelectrochemical Immunosensing Platform Based on CdSeTe@CdS:Mn Core–Shell Quantum Dots-Sensitized TiO2 Amplified by CuS Nanocrystals Conjugated Signal Antibodies. Analytical Chemistry. https://doi.org/10.1021/acs.analchem.6b00144
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.