Student or educator? Sign up with your school email and get 6 months of Pro free.
Cited by 204

The DOI matches its Crossref record; 6 of the 6 references it cites were found in a registry or an index.

Electrochemical Sandwich Immunosensor for Determination of Exosomes Based on Surface Marker-Mediated Signal Amplification

Doldán, Ximena, Fagúndez, Pablo, Cayota, Alfonso, Laíz, Justo, Tosar, Juan Pablo·2016·Analytical Chemistry

Abstract

Extracellular vesicles (EVs), namely, exosomes and microvesicles, are important mediators of intercellular communication pathways. Since EVs can be detected in a variety of biofluids and contain a specific set of biomarkers which are reminiscent of their parental cells, they show great promise in clinical diagnostics as EV analysis can be performed in minimally invasive liquid biopsies. However, reliable, fast and cost-effective methods for their determination are still needed, especially if decentralized analysis is intended. In this study, we developed an electrochemical biosensor which works with 1.5 μL sample volume and can detect as low as 200 exosomes per microliter, with a linear range spanning almost 4 orders of magnitude. The sensor is specific and readily differentiates exosomes from microvesicles in samples containing 1000-fold excess of the latter. Capability of detecting exosomes in real samples (diluted serum) was shown. This was achieved by immobilizing rabbit antihuman CD9 antibodies on gold substrates and using monoclonal antibodies against CD9 for detection of captured exosomes. Signal amplification is presumably obtained from the fact that multiple detector antibodies bind to the surface of each captured vesicle. Detection is performed based on electrochemical reduction of 3,3',5,5'-tetramethyl benzidine (TMB) after addition of horseradish peroxidase (HRP)-conjugated anti-IgG antibodies. This amperometric biosensor can be easily incorporated into future miniaturized and semiautomatic devices for EV determination.

Overview

The claims and statistics of this paper haven’t been checked yet.

Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.

A few free checks a day · papers already verified open instantly · results are public

Integrity signals

Registry

Crossref · 10.1021/acs.analchem.6b02421

Cites

6 of 6 references verified0 citation errors · 0 not checkable

Statistics

Verification

Claims the paper makes

The claims and statistics of this paper haven’t been checked yet.

Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.

A few free checks a day · papers already verified open instantly · results are public

Self-check

Percentages, sums and reported differences re-computed from the paper’s own numbers.

The self-check needs the paper’s full text.

Citations

Cites

Show all 6 references

Cited by

See all 204

Metadata

Authors
Doldán, X., Fagúndez, P., Cayota, A., Laíz, J., & Tosar, J. P.
Venue
Analytical Chemistry
Published
2016-10-20
Volume
88
Issue
21
Pages
10466-10473
ISSN
  • 0003-2700 (ISSN-L)
  • 1520-6882
OpenAlex
W2531252532
Cited by
204
References
6
FWCI
7.98
Type
journal article
Language
en
Open access
closed

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review

How to cite

Cite CoChat for the checks on this page, and the paper for its own findings.

This page
CoChat. (2026). Citation check: Electrochemical Sandwich Immunosensor for Determination of Exosomes Based on Surface Marker-Mediated Signal Amplification. https://app.cochat.ai/papers/10.1021/acs.analchem.6b02421
The paper
Doldán, X., Fagúndez, P., Cayota, A., Laíz, J., & Tosar, J. P. (2016). Electrochemical Sandwich Immunosensor for Determination of Exosomes Based on Surface Marker-Mediated Signal Amplification. Analytical Chemistry. https://doi.org/10.1021/acs.analchem.6b02421

Data sources

Bibliographic data: Semantic Scholar, OpenAlex, Crossref.

Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).

Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.