The DOI matches its Crossref record; 2 of the 2 references it cites were found in a registry or an index.
Highly Specific and Ultrasensitive Two-Photon Fluorescence Imaging of Native HOCl in Lysosomes and Tissues Based on Thiocarbamate Derivatives
Abstract
Hypochlorous acid (HOCl) acts as a weak acid distributed mainly in acidic organelle lysosomes of phagocytes and plays a crucial role in the immune defense. The elaborate interrelation between the variations of HOCl levels in lysosomes and different physiological and pathological processes remains unclear. Thus, the accurate determination of lysosomal HOCl in living cells and in vivo is very important. Because of extremely low concentration and difficulty in distinguishing HOCl from OCl – under the physiological environment, it is still a great challenge to specifically monitor the intracellular intrinsic HOCl levels without exogenous stimulation, which impedes an exact understanding of its biological roles. In this paper, based on the electrophilic addition of Cl + to sulfide moiety, we have developed a two-photon fluorescent probe O -( N -butyl-1,8-naphthalimide)-4-yl- N, N -dimethylthiocarbamate ( NDMTC ) for the specific determination of HOCl over OCl – and other bioactive molecules. Our results show that NDMTC possesses a detection limit of 7.6 pM, and it is the first fluorescent probe for detecting HOCl at the picomolar level. Furthermore, by introducing an alkylmorpholine group to the NDMTC framework, the lysosome-targetable derivative Lyso-NDMTC was obtained, and its ability to image HOCl in the lysosome organelles was clearly confirmed. Combined with two-photon fluorescence imaging of background suppression and deeper tissue penetration, NDMTC and Lyso-NDMTC were used to successfully visualize intracellular native HOCl and discern tumor tissue in mice. This study offers two perfect fluorescence imaging probes for further investigation of pathological roles of HOCl in various diseases.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Reactive oxygen species in cancer cells: Live by the sword, die by the sword
Schumacker, P. T. (2006) · Cancer Cell · doi:10.1016/j.ccr.2006.08.015 · Cited by 1,242
Chen, X., Lee, K.-A., Ha, E.-M., Lee, K. M., Seo, Y. Y., Choi, H. K., Kim, H. N., Kim, M. J., Cho, C.-S., Lee, S. Y., et al. (2011) · Chemical Communications · doi:10.1039/c1cc10589b · Cited by 246
Cited by
Fluorescent probes for organelle-targeted bioactive species imaging
Gao, P., Pan, W., Li, N., & Tang, B. (2019) · Chemical Science · doi:10.1039/c9sc01652j · Cited by 599
Self-citationJiao, X., Li, Y., Niu, J., Xie, X., Wang, X., & Tang, B. (2018) · Analytical Chemistry · doi:10.1021/acs.analchem.7b04234 · Cited by 484
Self-citation
Metadata
- Authors
- Zhu, B., Li, P., Shu, W., Wang, X., Liu, C., Wang, Y., Wang, Z., Wang, Y., & Tang, B.
- Venue
- Analytical Chemistry
- Publisher
- American Chemical Society (ACS)
- Published
- 2016-12-08
- Volume
- 88
- Issue
- 24
- Pages
- 12532-12538
- ISSN
- 0003-2700 (ISSN-L)
- 1520-6882
- OpenAlex
- W2551553940
- Cited by
- 221
- References
- 2
- FWCI
- 15.17
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.