The DOI matches its Crossref record; 31 of the 31 references it cites were found in a registry or an index.
One Step Forward for Reducing False Positive and False Negative Compound Identifications from Mass Spectrometry Metabolomics Data: New Algorithms for Constructing Extracted Ion Chromatograms and Detecting Chromatographic Peaks
Abstract
False positive and false negative peaks detected from extracted ion chromatograms (EIC) are an urgent problem with existing software packages that preprocess untargeted liquid or gas chromatography-mass spectrometry metabolomics data because they can translate downstream into spurious or missing compound identifications. We have developed new algorithms that carry out the sequential construction of EICs and detection of EIC peaks. We compare the new algorithms to two popular software packages XCMS and MZmine 2 and present evidence that these new algorithms detect significantly fewer false positives. Regarding the detection of compounds known to be present in the data, the new algorithms perform at least as well as XCMS and MZmine 2. Furthermore, we present evidence that mass tolerance in m/z should be favored rather than mass tolerance in ppm in the process of constructing EICs. The mass tolerance parameter plays a critical role in the EIC construction process and can have immense impact on the detection of EIC peaks.
Overview
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Smith, C. A., Want, E. J., O'Maille, G., Abagyan, R., & Siuzdak, G. (2006) · Analytical Chemistry · doi:10.1021/ac051437y · Cited by 5,262
Pluskal, T., Castillo, S., Villar-Briones, A., & Orešič, M. (2010) · BMC Bioinformatics · doi:10.1186/1471-2105-11-395 · Cited by 3,845
The Human Serum Metabolome (HUSERMET) Consortium, Dunn, W. B., Broadhurst, D., Begley, P., Zelena, E., Francis-McIntyre, S., Anderson, N., Brown, M., Knowles, J. D., Halsall, A., et al. (2011) · Nature Protocols · doi:10.1038/nprot.2011.335 · Cited by 3,294
ProteoWizard: open source software for rapid proteomics tools development
Kessner, D., Chambers, M., Burke, R., Agus, D., & Mallick, P. (2008) · Bioinformatics · doi:10.1093/bioinformatics/btn323 · Cited by 2,024
XCMS Online: A Web-Based Platform to Process Untargeted Metabolomic Data
Tautenhahn, R., Patti, G. J., Rinehart, D., & Siuzdak, G. (2012) · Analytical Chemistry · doi:10.1021/ac300698c · Cited by 1,319
Highly sensitive feature detection for high resolution LC/MS
Tautenhahn, R., Böttcher, C., & Neumann, S. (2008) · BMC Bioinformatics · doi:10.1186/1471-2105-9-504 · Cited by 1,185
Metabolomics by Gas Chromatography–Mass Spectrometry: Combined Targeted and Untargeted Profiling
Fiehn, O. (2016) · Current Protocols in Molecular Biology · doi:10.1002/0471142727.mb3004s114 · Cited by 917
Dunn, W. B., Broadhurst, D. I., Atherton, H. J., Goodacre, R., & Griffin, J. L. (2011) · Chem. Soc. Rev. · doi:10.1039/b906712b · Cited by 860
MZmine: toolbox for processing and visualization of mass spectrometry based molecular profile data
Katajamaa, M., Miettinen, J., & Orešič, M. (2006) · Bioinformatics · doi:10.1093/bioinformatics/btk039 · Cited by 831
Du, P., Kibbe, W. A., & Lin, S. M. (2006) · Bioinformatics · doi:10.1093/bioinformatics/btl355 · Cited by 763
Cited by
Antiviral activity of bacterial TIR domains via immune signalling molecules
Ofir, G., Herbst, E., Baroz, M., Cohen, D., Millman, A., Doron, S., Tal, N., Malheiro, D. B. A., Malitsky, S., Amitai, G., et al. (2021) · Nature · doi:10.1038/s41586-021-04098-7 · Cited by 342
Asparagine couples mitochondrial respiration to ATF4 activity and tumor growth
Krall, A. S., Mullen, P. J., Surjono, F., Momcilovic, M., Schmid, E. W., Halbrook, C. J., Thambundit, A., Mittelman, S. D., Lyssiotis, C. A., Shackelford, D. B., et al. (2021) · Cell Metabolism · doi:10.1016/j.cmet.2021.02.001 · Cited by 266
Current and future perspectives of functional metabolomics in disease studies–A review
Yan, M., & Xu, G. (2018) · Analytica Chimica Acta · doi:10.1016/j.aca.2018.04.006 · Cited by 105
Wu, E., Wang, K., Liu, Z., Wang, J., Yan, H., Zhu, X., Zhu, X., & Chen, B. (2023) · Environmental Science & Technology · doi:10.1021/acs.est.3c07020 · Cited by 88
Chemometric-Guided Approaches for Profiling and Authenticating Botanical Materials
Abraham, E. J., & Kellogg, J. J. (2021) · Frontiers in Nutrition · doi:10.3389/fnut.2021.780228 · Cited by 64
Metadata
- Authors
- Myers, O. D., Sumner, S. J., Li, S., Barnes, S., & Du, X.
- Venue
- Analytical Chemistry
- Publisher
- American Chemical Society (ACS)
- Published
- 2017-08-17
- Volume
- 89
- Issue
- 17
- Pages
- 8696-8703
- ISSN
- 0003-2700 (ISSN-L)
- 1520-6882
- OpenAlex
- W2740856177
- Cited by
- 433
- References
- 31
- FWCI
- 7.67
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: One Step Forward for Reducing False Positive and False Negative Compound Identifications from Mass Spectrometry Metabolomics Data: New Algorithms for Constructing Extracted Ion Chromatograms and Detecting Chromatographic Peaks. https://app.cochat.ai/papers/10.1021/acs.analchem.7b00947
- The paper
- Myers, O. D., Sumner, S. J., Li, S., Barnes, S., & Du, X. (2017). One Step Forward for Reducing False Positive and False Negative Compound Identifications from Mass Spectrometry Metabolomics Data: New Algorithms for Constructing Extracted Ion Chromatograms and Detecting Chromatographic Peaks. Analytical Chemistry. https://doi.org/10.1021/acs.analchem.7b00947
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.