Student or educator? Sign up with your school email and get 6 months of Pro free.
Cited by 567

The DOI matches its Crossref record; 1 of the 1 references it cites were found in a registry or an index.

Bioresponsive Release System for Visual Fluorescence Detection of Carcinoembryonic Antigen from Mesoporous Silica Nanocontainers Mediated Optical Color on Quantum Dot-Enzyme-Impregnated Paper

Qiu, Zhenli, Shu, Jian, Tang, Dianping·2017·Analytical Chemistry

Abstract

An all-in-one paper-based analytical device (PAD) was successfully developed for visual fluorescence detection of carcinoembryonic antigen (CEA) on CdTe/CdSe quantum dot (QD)-enzyme-impregnated paper by coupling with a bioresponsive controlled-release system from DNA-gated mesoporous silica nanocontainers (MSNs). The assay was carried out in a centrifuge tube by using glucose-loaded MSNs with a CEA aptamer and a QD-enzyme-paper attached on the lid. Initially, single-strand complementary DNA to a CEA aptamer was covalently conjugated to the aminated MSN, and then glucose (enzyme substrate) molecules were gated into the pore with the help of the aptamer. Glucose oxidase (GOD) and CdTe/CdSe QDs were coimmobilized on paper for the visual fluorescence signal output. Upon target CEA introduction in the detection cell, the analyte specifically reacted with the immobilized aptamer on the MSN to open the pore, thereby resulting in the glucose release. The released glucose was oxidized by the immobilized GOD on paper to produce gluconic acid and hydrogen peroxide, and the latter quenched the fluorescence of CdTe/CdSe QDs, which could be determined by the naked eye on a portable smartphone and a commercial fluorospectrometer. Under optimal conditions, the PAD-based sensing system enabled sensitive discrimination of target CEA against other biomarkers or proteins in a linear range of 0.05–20 ng mL –1 with a limit of detection of 6.7 pg mL –1 (ppt). In addition, our strategy displayed high specificity, good reproducibility, and acceptable accuracy for analyzing human serum specimens with a commercial human CEA ELISA kit. Importantly, this methodology offers promise for simple analysis of biological samples and is suitable for use in the mass production of miniaturized devices, thus opening new opportunities for protein diagnostics and biosecurity.

Overview

The claims and statistics of this paper haven’t been checked yet.

Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.

A few free checks a day · papers already verified open instantly · results are public

Integrity signals

Registry

Crossref · 10.1021/acs.analchem.7b00989

Cites

1 of 1 references verified0 citation errors · 0 not checkable

Statistics

Verification

Claims the paper makes

The claims and statistics of this paper haven’t been checked yet.

Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.

A few free checks a day · papers already verified open instantly · results are public

Self-check

Percentages, sums and reported differences re-computed from the paper’s own numbers.

The self-check needs the paper’s full text.

Citations

Cites

Show all 1 references

Cited by

Metadata

Authors
Qiu, Z., Shu, J., & Tang, D.
Venue
Analytical Chemistry
Published
2017-04-12
Volume
89
Issue
9
Pages
5152-5160
ISSN
  • 0003-2700 (ISSN-L)
  • 1520-6882
OpenAlex
W2604463251
Cited by
567
References
1
FWCI
22.81
Type
journal article
Language
en
Open access
closed

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review

Data sources

Bibliographic data: Semantic Scholar, OpenAlex, Crossref.

Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).

Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.