The DOI matches its Crossref record; 28 of the 28 references it cites were found in a registry or an index.
Highly Fe3+-Selective Fluorescent Nanoprobe Based on Ultrabright N/P Codoped Carbon Dots and Its Application in Biological Samples
Abstract
Measuring the levels of Fe 3+ in human body has attracted considerable attention for health monitoring as it plays an essential role in many physiological processes. In this work, we reported a selective fluorescent nanoprobe for Fe 3+ detection in biological samples based on ultrabright N/P codoped carbon dots. By employing adenosine 5′-triphosphate (ATP) as the carbon, nitrogen, and phosphorus source, the N/P codoped carbon dots could be simply prepared through hydrothermal treatment. The obtained carbon dots exhibited high quantum yields up to 43.2%, as well as excellent photostability, low toxicity, and water solubility. Because of the Fe–O–P bonds formed between Fe 3+ and the N/P codoped carbon dots, this nanoprobe showed high selectivity toward Fe 3+ against various potential interfering substances in the presence of EDTA. The fluorescence quenching of as-fabricated carbon dots was observed with the increasing Fe 3+ concentration, and the calibration curve displayed a wide linear region over the range of 1–150 μM with a detection limit of 0.33 μM. The satisfactory accuracy was further confirmed with the river samples and ferrous sulfate tablets, respectively. With the above outstanding properties, these N/P codoped carbon dots were successfully applied for direct detection of Fe 3+ in biological samples including human blood serum and living cells. As compared to the most reported carbon dots-based Fe 3+ sensors, this nanoprobe showed high fluorescence, good accuracy, and excellent selectivity, which presents the potential practical application for diagnosis of Fe 3+ related disease.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Highly Photoluminescent Carbon Dots for Multicolor Patterning, Sensors, and Bioimaging
Zhu, S., Meng, Q., Wang, L., Zhang, J., Song, Y., Jin, H., Zhang, K., Sun, H., Wang, H., & Yang, B. (2013) · Angewandte Chemie International Edition · doi:10.1002/anie.201300519 · Cited by 3,720
Iron and cancer: more ore to be mined
Torti, S. V., & Torti, F. M. (2013) · Nature Reviews Cancer · doi:10.1038/nrc3495 · Cited by 1,621
A Biocompatible Fluorescent Ink Based on Water‐Soluble Luminescent Carbon Nanodots
Qu, S., Wang, X., Lu, Q., Liu, X., & Wang, L. (2012) · Angewandte Chemie International Edition · doi:10.1002/anie.201206791 · Cited by 1,297
Baker, R. D., Greer, F. R., & The Committee on Nutrition (2010) · Pediatrics · doi:10.1542/peds.2010-2576 · Cited by 1,033
Nitrogen-doped, carbon-rich, highly photoluminescent carbon dots from ammonium citrate
Yang, Z., Xu, M., Liu, Y., He, F., Gao, F., Su, Y., Wei, H., & Zhang, Y. (2014) · Nanoscale · doi:10.1039/c3nr05380f · Cited by 939
Shen, P., & Xia, Y. (2014) · Analytical Chemistry · doi:10.1021/ac5001338 · Cited by 596
Green Synthesis of Luminescent Nitrogen-Doped Carbon Dots from Milk and Its Imaging Application
Wang, L., & Zhou, H. S. (2014) · Analytical Chemistry · doi:10.1021/ac502646x · Cited by 575
Li, S., Li, Y., Cao, J., Zhu, J., Fan, L., & Li, X. (2014) · Analytical Chemistry · doi:10.1021/ac503183y · Cited by 564
Liu, Y., Duan, W., Song, W., Liu, J., Ren, C., Wu, J., Liu, D., & Chen, H. (2017) · ACS Applied Materials & Interfaces · doi:10.1021/acsami.6b15746 · Cited by 521
Facile access to versatile fluorescent carbon dots toward light-emitting diodes
Guo, X., Wang, C.-F., Yu, Z.-Y., Chen, L., & Chen, S. (2012) · Chemical Communications · doi:10.1039/c2cc17769b · Cited by 504
Wang, N., Wang, Y., Guo, T., Yang, T., Chen, M., & Wang, J. (2016) · Biosensors and Bioelectronics · doi:10.1016/j.bios.2016.04.089 · Cited by 417
Qian, Z., Shan, X., Chai, L., Ma, J., Chen, J., & Feng, H. (2014) · ACS Applied Materials & Interfaces · doi:10.1021/am500403n · Cited by 382
Gong, X., Zhang, Q., Gao, Y., Shuang, S., Choi, M. M. F., & Dong, C. (2016) · ACS Applied Materials & Interfaces · doi:10.1021/acsami.6b01577 · Cited by 311
Dong, Y., Cai, J., Fang, Q., You, X., & Chi, Y. (2016) · Analytical Chemistry · doi:10.1021/acs.analchem.5b03974 · Cited by 280
Water-soluble and phosphorus-containing carbon dots with strong green fluorescence for cell labeling
Wang, W., Li, Y., Cheng, L., Cao, Z., & Liu, W. (2014) · J. Mater. Chem. B · doi:10.1039/c3tb21370f · Cited by 253
Han, C., Wang, R., Wang, K., Xu, H., Sui, M., Li, J., & Xu, K. (2016) · Biosensors and Bioelectronics · doi:10.1016/j.bios.2016.04.066 · Cited by 203
Self-citationPhysiology and pathophysiology of iron in hemoglobin-associated diseases
Coates, T. D. (2014) · Free Radical Biology and Medicine · doi:10.1016/j.freeradbiomed.2014.03.039 · Cited by 181
Copper(ii) and iron(ii) ion sensing with semiconducting polymer dots
Chan, Y.-H., Jin, Y., Wu, C., & Chiu, D. T. (2011) · Chemical Communications · doi:10.1039/c0cc04929h · Cited by 161
Photoluminescent organosilane-functionalized carbon dots as temperature probes
Chen, P.-C., Chen, Y.-N., Hsu, P.-C., Shih, C.-C., & Chang, H.-T. (2013) · Chemical Communications · doi:10.1039/c3cc38486a · Cited by 158
High nontransferrin bound iron levels and heart disease in thalassemia major
Piga, A. G., Longo, F., Duca, L., Roggero, S., Vinciguerra, T., Calabrese, R., Hershko, C., & Cappellini, M. D. (2008) · American Journal of Hematology · doi:10.1002/ajh.21317 · Cited by 146
Singh, V., & Mishra, A. K. (2015) · Sensors and Actuators B Chemical · doi:10.1016/j.snb.2015.12.071 · Cited by 112
Kim, Y. W., Lee, S. M., Shin, S. M., Hwang, S. J., Brooks, J. S., Kang, H. E., Lee, M. G., Kim, S. C., & Kim, S. G. (2009) · Free Radical Biology and Medicine · doi:10.1016/j.freeradbiomed.2009.07.018 · Cited by 106
Carpenter, C. D., & Payne, S. M. (2014) · Journal of Inorganic Biochemistry · doi:10.1016/j.jinorgbio.2014.01.007 · Cited by 104
Long, L., Zhou, L., Wang, L., Meng, S., Gong, A., & Zhang, C. (2014) · Analytica Chimica Acta · doi:10.1016/j.aca.2013.12.024 · Cited by 102
Yang, Q., Wei, L., Zheng, X., & Xiao, L. (2015) · Scientific Reports · doi:10.1038/srep17727 · Cited by 97
Wu, P.-J., Kuo, S.-Y., Huang, Y.-C., Chen, C.-P., & Chan, Y. (2014) · Analytical Chemistry · doi:10.1021/ac404237q · Cited by 96
Matai, I., Sachdev, A., & Gopinath, P. (2015) · ACS Applied Materials & Interfaces · doi:10.1021/acsami.5b02095 · Cited by 96
Şenol, A. M., Onganer, Y., & Meral, K. (2016) · Sensors and Actuators B Chemical · doi:10.1016/j.snb.2016.08.025 · Cited by 87
Cited by
Carbon dots: synthesis, formation mechanism, fluorescence origin and sensing applications
Liu, M. L., Chen, B. B., Li, C. M., & Huang, C. Z. (2019) · Green Chemistry · doi:10.1039/c8gc02736f · Cited by 1,274
Review of Carbon and Graphene Quantum Dots for Sensing
Li, M., Chen, T., Gooding, J. J., & Liu, J. (2019) · ACS Sensors · doi:10.1021/acssensors.9b00514 · Cited by 991
Qi, H., Teng, M., Liu, M., Liu, S., Li, J., Yu, H., Teng, C., Huang, Z., Liu, H., Shao, Q., et al. (2019) · Journal of Colloid and Interface Science · doi:10.1016/j.jcis.2018.12.047 · Cited by 640
Li, L., & Dong, T. (2018) · Journal of Materials Chemistry C · doi:10.1039/c7tc05878k · Cited by 452
Applications of carbon dots in environmental pollution control: A review
Long, C., Jiang, Z., Shangguan, J., Qing, T., Zhang, P., & Feng, B. (2021) · Chemical Engineering Journal · doi:10.1016/j.cej.2020.126848 · Cited by 434
Self-citation
Metadata
- Authors
- Shangguan, J., Huang, J., He, D., He, X., Wang, K., Ye, R., Yang, X., Qing, T., & Tang, J.
- Venue
- Analytical Chemistry
- Publisher
- American Chemical Society (ACS)
- Published
- 2017-07-03
- Volume
- 89
- Issue
- 14
- Pages
- 7477-7484
- ISSN
- 0003-2700 (ISSN-L)
- 1520-6882
- OpenAlex
- W2681066983
- Cited by
- 337
- References
- 28
- FWCI
- 16.60
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.