Nonenzymatic Sensor for Lactate Detection in Human Sweat
The DOI matches its Crossref record; 2 of the 2 references it cites were found in a registry or an index.
Abstract
High Resolution Image Download MS PowerPoint Slide For noninvasive diagnostics of hypoxia, we propose the nonenzymatic sensor based on screen-printed structures with the working surface modified in course of electropolymerization of 3-aminophenylboronic acid (3-APBA) with imprinting of lactate. Impedimetric sensor allows lactate detection in the range from 3 mM to 100 mM with the detection limit of 1.5 mM; response time is 2–3 min. Sensor sensitivity remains unchanged within 6 months of storage unpacked in dry state at a room temperature, which is unachievable for enzyme based devices. Analysis of human sweat with poly(3-APBA) based sensor is possible due to (i) much higher lactate content compared to other polyols and (ii) high sensor selectivity ( K lactate glucose < 3 × 10 –2 ). Successful detection of lactate in human sweat by means of the poly(3-APBA) based sensor has been confirmed using the highly specific reference method based on lactate oxidase enzyme (correlation coefficient r > 0.9). The attractive performance characteristics of poly(3-APBA) based enzyme-free sensors justify their future use for noninvasive clinical analysis and sports medicine.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Electrochemical Tattoo Biosensors for Real-Time Noninvasive Lactate Monitoring in Human Perspiration
Jia, W., Bandodkar, A. J., Valdés-Ramírez, G., Windmiller, J. R., Yang, Z., Ramírez, J., Chan, G., & Wang, J. (2013) · Analytical Chemistry · doi:10.1021/ac401573r · Cited by 862
Stretchable biofuel cells as wearable textile-based self-powered sensors
Jeerapan, I., Sempionatto, J. R., Pavinatto, A., You, J.-M., & Wang, J. (2016) · Journal of Materials Chemistry A · doi:10.1039/c6ta08358g · Cited by 317
Cited by
Wearable flexible sweat sensors for healthcare monitoring: a review
Chung, M., Fortunato, G., & Radacsi, N. (2019) · Journal of The Royal Society Interface · doi:10.1098/rsif.2019.0217 · Cited by 378
Wearable Biosensors: An Alternative and Practical Approach in Healthcare and Disease Monitoring
Sharma, A., Badea, M., Tiwari, S., & Marty, J. L. (2021) · Molecules · doi:10.3390/molecules26030748 · Cited by 357
A Wearable Cellulose Acetate-Coated Mouthguard Biosensor for In Vivo Salivary Glucose Measurement
Arakawa, T., Tomoto, K., Nitta, H., Toma, K., Takeuchi, S., Sekita, T., Minakuchi, S., & Mitsubayashi, K. (2020) · Analytical Chemistry · doi:10.1021/acs.analchem.0c01201 · Cited by 313
Progress and challenges in fabrication of wearable sensors for health monitoring
Nasiri, S., & Khosravani, M. R. (2020) · Sensors and Actuators A: Physical · doi:10.1016/j.sna.2020.112105 · Cited by 295
Xiao, J., Liu, Y., Su, L., Zhao, D., Zhao, L., & Zhang, X. (2019) · Analytical Chemistry · doi:10.1021/acs.analchem.9b03110 · Cited by 288
Metadata
- Authors
- Zaryanov, N. V., Nikitina, V. N., Karpova, E. V., Karyakina, E. E., & Karyakin, A. A.
- Venue
- Analytical Chemistry
- Publisher
- American Chemical Society (ACS)
- Published
- 2017-10-26
- Volume
- 89
- Issue
- 21
- Pages
- 11198-11202
- ISSN
- 0003-2700 (ISSN-L)
- 1520-6882
- OpenAlex
- W2765968595
- Cited by
- 154
- References
- 2
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: Nonenzymatic Sensor for Lactate Detection in Human Sweat. https://app.cochat.ai/papers/10.1021/acs.analchem.7b03662
- The paper
- Zaryanov, N. V., Nikitina, V. N., Karpova, E. V., Karyakina, E. E., & Karyakin, A. A. (2017). Nonenzymatic Sensor for Lactate Detection in Human Sweat. Analytical Chemistry. https://doi.org/10.1021/acs.analchem.7b03662
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.