The DOI matches its Crossref record; 1 of the 1 references it cites were found in a registry or an index.
Raman-Activated Droplet Sorting (RADS) for Label-Free High-Throughput Screening of Microalgal Single-Cells
Open accessAbstract
Raman-activated cell sorting (RACS) has attracted increasing interest, yet throughput remains one major factor limiting its broader application. Here we present an integrated Raman-activated droplet sorting (RADS) microfluidic system for functional screening of live cells in a label-free and high-throughput manner, by employing AXT-synthetic industrial microalga Haematococcus pluvialis (H. pluvialis) as a model. Raman microspectroscopy analysis of individual cells is carried out prior to their microdroplet encapsulation, which is then directly coupled to DEP-based droplet sorting. To validate the system, H. pluvialis cells containing different levels of AXT were mixed and underwent RADS. Those AXT-hyperproducing cells were sorted with an accuracy of 98.3%, an enrichment ratio of eight folds, and a throughput of ∼260 cells/min. Of the RADS-sorted cells, 92.7% remained alive and able to proliferate, which is equivalent to the unsorted cells. Thus, the RADS achieves a much higher throughput than existing RACS systems, preserves the vitality of cells, and facilitates seamless coupling with downstream manipulations such as single-cell sequencing and cultivation.
Overview
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Liu, J., & Huang, Q. (2016) · Applied Spectroscopy · doi:10.1177/0003702816645605 · Cited by 45
Cited by
High-Throughput Screening Technology in Industrial Biotechnology
Zeng, W., Guo, L., Xu, S., Chen, J., & Zhou, J. (2020) · Trends in Biotechnology · doi:10.1016/j.tibtech.2020.01.001 · Cited by 317
Next-generation physiology approaches to study microbiome function at single cell level
Hatzenpichler, R., Krukenberg, V., Spietz, R. L., & Jay, Z. J. (2020) · Nature Reviews Microbiology · doi:10.1038/s41579-020-0323-1 · Cited by 297
Heidari Baladehi, M., Hekmatara, M., He, Y., Bhaskar, Y., Wang, Z., Liu, L., Ji, Y., & Xu, J. (2021) · Analytical Chemistry · doi:10.1021/acs.analchem.1c01015 · Cited by 46
Self-citationMicrofluidics for Microalgal Biotechnology
Ozdalgic, B., Ustun, M., Dabbagh, S. R., Haznedaroglu, B. Z., Kiraz, A., & Tasoglu, S. (2021) · Biotechnology and Bioengineering · doi:10.1002/bit.27669 · Cited by 37
Neun, S., van Vliet, L., Hollfelder, F., & Gielen, F. (2022) · Analytical Chemistry · doi:10.1021/acs.analchem.2c03164 · Cited by 20
Metadata
- Authors
- Wang, X., Ren, L., Su, Y., Ji, Y., Liu, Y., Li, C., Li, X., Zhang, Y., Wang, W., Hu, Q., Han, D., Xu, J., & Ma, B.
- Venue
- Analytical Chemistry
- Publisher
- American Chemical Society (ACS)
- Published
- 2017-11-09
- Volume
- 89
- Issue
- 22
- Pages
- 12569-12577
- ISSN
- 0003-2700 (ISSN-L)
- 1520-6882
- OpenAlex
- W2765974283
- Cited by
- 164
- References
- 1
- FWCI
- 4.66
- Type
- journal article
- Language
- en
- Open access
- green
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: Raman-Activated Droplet Sorting (RADS) for Label-Free High-Throughput Screening of Microalgal Single-Cells. https://app.cochat.ai/papers/10.1021/acs.analchem.7b03884
- The paper
- Wang, X., Ren, L., Su, Y., Ji, Y., Liu, Y., Li, C., Li, X., Zhang, Y., Wang, W., Hu, Q., Han, D., Xu, J., & Ma, B. (2017). Raman-Activated Droplet Sorting (RADS) for Label-Free High-Throughput Screening of Microalgal Single-Cells. Analytical Chemistry. https://doi.org/10.1021/acs.analchem.7b03884
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.