The DOI matches its Crossref record; 42 of the 42 references it cites were found in a registry or an index.
21 Tesla FT-ICR Mass Spectrometer for Ultrahigh-Resolution Analysis of Complex Organic Mixtures
Abstract
We describe complex organic mixture analysis by 21 tesla (T) Fourier transform ion cyclotron resonance mass spectrometry (FT-ICR MS). Ultrahigh mass-resolving power ( m /Δ m 50% > 2 700 000 at m / z 400) and mass accuracy (80 ppb rms) enable resolution and confident identification of tens of thousands of unique elemental compositions. We demonstrate 2.2-fold higher mass-resolving power, 2.6-fold better mass measurement accuracy, and 1.3-fold more assigned molecular formulas compared to our custom-built, state-of-the-art 9.4 T FT-ICR mass spectrometer for petroleum and dissolved organic matter (DOM) analyses. Analysis of a heavy petroleum distillate exemplifies the need for ultrahigh-performance mass spectrometry (49 040 assigned molecular formulas for 21 T versus 29 012 for 9.4 T) and extends the identification of previously unresolved O o, S s O o, and NO o classes. Mass selective ion accumulation (20 Thompson isolation) of an asphalt volcano sample yields 462 resolved mass spectral peaks at m / z 677 and reveals previously unresolved C c H h N n O o S s mass differences at high mass ( m / z > 600). Similar performance gains are realized in the analysis of dissolved organic matter, where doubly charged O o species are resolved from singly charged SO o species, which requires a mass-resolving power greater than 1 400 000 (at m / z 600). This direct comparison reveals the continued need for higher mass-resolving power and better mass accuracy for comprehensive molecular characterization of the most complex organic mixtures.
Overview
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Electrospray Ionization for Mass Spectrometry of Large Biomolecules
Fenn, J. B., Mann, M., Meng, C. K., Wong, S. F., & Whitehouse, C. M. (1989) · Science · doi:10.1126/science.2675315 · Cited by 7,634
Fourier transform ion cyclotron resonance mass spectrometry: A primer
Marshall, A. G., Hendrickson, C. L., & Jackson, G. S. (1998) · Mass Spectrometry Reviews · doi:10.1002/(sici)1098-2787(1998)17:1<1::aid-mas1>3.0.co;2-k · Cited by 1,990
Self-citationCharacterization of a major refractory component of marine dissolved organic matter
Hertkorn, N., Benner, R., Frommberger, M., Schmitt-Kopplin, P., Witt, M., Kaiser, K., Kettrup, A., & Hedges, J. I. (2006) · Geochimica et Cosmochimica Acta · doi:10.1016/j.gca.2006.03.021 · Cited by 943
Molecular characterization of dissolved organic matter (DOM): a critical review
Nebbioso, A., & Piccolo, A. (2013) · Analytical and Bioanalytical Chemistry · doi:10.1007/s00216-012-6363-2 · Cited by 752
Robb, D. B., Covey, T. R., & Bruins, A. P. (2000) · Analytical Chemistry · doi:10.1021/ac0001636 · Cited by 748
Persistence of dissolved organic matter in lakes related to its molecular characteristics
Kellerman, A. M., Kothawala, D. N., Dittmar, T., & Tranvik, L. J. (2015) · Nature Geoscience · doi:10.1038/ngeo2440 · Cited by 737
Petroleomics: Chemistry of the underworld
Marshall, A. G., & Rodgers, R. P. (2008) · Proceedings of the National Academy of Sciences · doi:10.1073/pnas.0805069105 · Cited by 673
Self-citationStenson, A. C., Marshall, A. G., & Cooper, W. T. (2003) · Analytical Chemistry · doi:10.1021/ac026106p · Cited by 641
Kujawinski, E. B., Del Vecchio, R., Blough, N. V., Klein, G. C., & Marshall, A. G. (2004) · Marine Chemistry · doi:10.1016/j.marchem.2004.06.038 · Cited by 298
Hendrickson, C. L., Quinn, J. P., Kaiser, N. K., Smith, D. F., Blakney, G. T., Chen, T., Marshall, A. G., Weisbrod, C. R., & Beu, S. C. (2015) · Journal of the American Society for Mass Spectrometry · doi:10.1007/s13361-015-1182-2 · Cited by 278
Self-citationPredator data station: A fast data acquisition system for advanced FT-ICR MS experiments
Blakney, G. T., Hendrickson, C. L., & Marshall, A. G. (2011) · International Journal of Mass Spectrometry · doi:10.1016/j.ijms.2011.03.009 · Cited by 261
Self-citationSavory, J. J., Kaiser, N. K., McKenna, A. M., Xian, F., Blakney, G. T., Rodgers, R. P., Hendrickson, C. L., & Marshall, A. G. (2011) · Analytical Chemistry · doi:10.1021/ac102943z · Cited by 255
Self-citationCho, Y., Ahmed, A., Islam, A., & Kim, S. (2015) · Mass Spectrometry Reviews · doi:10.1002/mas.21438 · Cited by 245
Anthropogenic aerosols as a source of ancient dissolved organic matter in glaciers
Stubbins, A., Hood, E., Raymond, P. A., Aiken, G. R., Sleighter, R. L., Hernes, P. J., Butman, D., Hatcher, P. G., Striegl, R. G., Schuster, P., et al. (2012) · Nature Geoscience · doi:10.1038/ngeo1403 · Cited by 240
A Novel 9.4 Tesla FTICR Mass Spectrometer with Improved Sensitivity, Mass Resolution, and Mass Range
Kaiser, N. K., Quinn, J. P., Blakney, G. T., Hendrickson, C. L., & Marshall, A. G. (2011) · Journal of the American Society for Mass Spectrometry · doi:10.1007/s13361-011-0141-9 · Cited by 223
Self-citationRodgers, R. P., & McKenna, A. M. (2011) · Analytical Chemistry · doi:10.1021/ac201080e · Cited by 213
Self-citationSoutham, A. D., Payne, T. G., Cooper, H. J., Arvanitis, T. N., & Viant, M. R. (2007) · Analytical Chemistry · doi:10.1021/ac062446p · Cited by 194
Automated Broadband Phase Correction of Fourier Transform Ion Cyclotron Resonance Mass Spectra
Xian, F., Hendrickson, C. L., Blakney, G. T., Beu, S. C., & Marshall, A. G. (2010) · Analytical Chemistry · doi:10.1021/ac101091w · Cited by 189
Self-citationAdvantages of High Magnetic Field for Fourier Transform Ion Cyclotron Resonance Mass Spectrometry
Marshall, A. G., & Guan, S. (1996) · Rapid Communications in Mass Spectrometry · doi:10.1002/(sici)1097-0231(199611)10:14<1819::aid-rcm686>3.0.co;2-z · Cited by 177
Headley, J. V., Barrow, M. P., Peru, K. M., Fahlman, B., Frank, R. A., Bickerton, G., McMaster, M. E., Parrott, J., & Hewitt, L. M. (2011) · Rapid Communications in Mass Spectrometry · doi:10.1002/rcm.5062 · Cited by 168
Effect of Experimental Parameters on the ESI FT-ICR Mass Spectrum of Fulvic Acid
Brown, T. L., & Rice, J. A. (2000) · Analytical Chemistry · doi:10.1021/ac9902087 · Cited by 160
Jaffé, R., Yamashita, Y., Maie, N., Cooper, W., Dittmar, T., Dodds, W. K., Jones, J. B., Myoshi, T., Ortíz-Zayas, J. R., Podgorski, D. C., et al. (2012) · Geochimica et Cosmochimica Acta · doi:10.1016/j.gca.2012.06.031 · Cited by 158
Self-citationPurcell, J. M., Merdrignac, I., Rodgers, R. P., Marshall, A. G., Gauthier, T. A., & Guibard, I. (2009) · Energy & Fuels · doi:10.1021/ef900897a · Cited by 158
Self-citationFievre, A., Solouki, T., Marshall, A. G., & Cooper, W. (1997) · Energy & Fuels · doi:10.1021/ef970005q · Cited by 148
Klein, G. C., Kim, S., Rodgers, R. P., et al. (2006) · Energy & Fuels · doi:10.1021/ef0600199 · Cited by 147
Self-citationBoldin, I. A., & Николаев, Е. Н. (2010) · Rapid Communications in Mass Spectrometry · doi:10.1002/rcm.4838 · Cited by 129
Shaw, J., Lin, T., Leach, F. E., Tolmachev, A. V., Tolić, N., Robinson, E. W., Koppenaal, D., & Paša‐Tolić, L. (2016) · Journal of the American Society for Mass Spectrometry · doi:10.1007/s13361-016-1507-9 · Cited by 122
Hodgkins, S. B., Tfaily, M., Podgorski, D. C., Mccalley, C. K., SALESKA, S. R., Crill, P., Rich, V. I., Chanton, J. P., & Cooper, W. (2016) · Geochimica et Cosmochimica Acta · doi:10.1016/j.gca.2016.05.015 · Cited by 116
Self-citationWagner, S., Jaffé, R., Cawley, K. M., Dittmar, T., & Stubbins, A. (2015) · Frontiers in Chemistry · doi:10.3389/fchem.2015.00066 · Cited by 113
Kaiser, N. K., Savory, J., Mckenna, A. M., Quinn, J. P., Hendrickson, C. L., & Marshall, A. G. (2011) · Analytical Chemistry · doi:10.1021/ac201546d · Cited by 109
Self-citationTrapped-ion cell with improved dc potential harmonicity for FT-ICR MS
Tolmachev, A. V., Robinson, E. W., Wu, S., Kang, H., Lourette, N. M., Paša‐Tolić, L., & Smith, R. D. (2008) · Journal of the American Society for Mass Spectrometry · doi:10.1016/j.jasms.2008.01.006 · Cited by 108
Advanced analytical techniques for bio‐oil characterization
Michailof, C. M., Kalogiannis, K. G., Sfetsas, T., Patiaka, D. T., & Lappas, A. A. (2016) · Wiley Interdisciplinary Reviews Energy and Environment · doi:10.1002/wene.208 · Cited by 106
Rowland, S. M., Robbins, W. K., Corilo, Y., Marshall, A. G., & Rodgers, R. P. (2014) · Energy & Fuels · doi:10.1021/ef5015023 · Cited by 92
Self-citationEvaluation of High-Field Orbitrap Fourier Transform Mass Spectrometer for Petroleomics
Zhurov, K. O., Kozhinov, A. N., & Tsybin, Y. O. (2013) · Energy & Fuels · doi:10.1021/ef400203g · Cited by 89
Absorption-Mode: The Next Generation of Fourier Transform Mass Spectra
Qi, Y., Barrow, M. P., Li, H., Meier, J. E., Orden, S. L. V., Thompson, C. J., & O’Connor, P. B. (2012) · Analytical Chemistry · doi:10.1021/ac3000122 · Cited by 84
Novel Method To Isolate Interfacial Material
Jarvis, J. M., Robbins, W. K., Corilo, Y., & Rodgers, R. P. (2015) · Energy & Fuels · doi:10.1021/acs.energyfuels.5b01787 · Cited by 76
Self-citationDecomposition of plankton-derived dissolved organic matter in permeable coastal sediments
Chipman, L., Podgorski, D. C., Green, S. J., Kostka, J. E., Cooper, W., & Huettel, M. (2010) · Limnology and Oceanography · doi:10.4319/lo.2009.55.2.0857 · Cited by 67
Self-citationKaiser, N. K., Mckenna, A. M., Savory, J., Hendrickson, C. L., & Marshall, A. G. (2012) · Analytical Chemistry · doi:10.1021/ac302678v · Cited by 58
Self-citationControlled Ion Ejection from an External Trap for Extended m/z Range in FT-ICR Mass Spectrometry
Kaiser, N. K., Savory, J., & Hendrickson, C. L. (2014) · Journal of the American Society for Mass Spectrometry · doi:10.1007/s13361-014-0871-6 · Cited by 46
Self-citationAbsorption‐mode spectra on the dynamically harmonized Fourier transform ion cyclotron resonance cell
Qi, Y., Witt, M., Jertz, R., Baykut, G., Barrow, M. P., Николаев, Е. Н., & O’Connor, P. B. (2012) · Rapid Communications in Mass Spectrometry · doi:10.1002/rcm.6311 · Cited by 38
Chen, T., Beu, S. C., Kaiser, N. K., & Hendrickson, C. L. (2014) · Review of Scientific Instruments · doi:10.1063/1.4883179 · Cited by 35
Self-citationIdentification of Calcium Naphthenate Deposition in South American Oil Fields
Juyal, P., Mapolelo, M. M., Yen, A. T., Rodgers, R. P., & Allenson, S. J. (2015) · Energy & Fuels · doi:10.1021/acs.energyfuels.5b00414 · Cited by 26
Self-citation
Cited by
A new conceptual framework for the transformation of groundwater dissolved organic matter
McDonough, L. K., Andersen, M. S., Behnke, M. I., Rutlidge, H., Oudone, P., Meredith, K., O’Carroll, D. M., Santos, I. R., Marjo, C. E., Spencer, R. G. M., et al. (2022) · Nature Communications · doi:10.1038/s41467-022-29711-9 · Cited by 284
He, C., Zhang, Y., Li, Y., Zhuo, X., Li, Y., Zhang, C., & Shi, Q. (2020) · ACS Omega · doi:10.1021/acsomega.0c01055 · Cited by 254
Plastic formulation is an emerging control of its photochemical fate in the ocean
Walsh, A. N., Reddy, C. M., Niles, S. F., McKenna, A. M., Hansel, C. M., & Ward, C. P. (2021) · Environmental Science & Technology · doi:10.1021/acs.est.1c02272 · Cited by 76
Salami, A., Heikkinen, J., Tomppo, L., Hyttinen, M., Kekäläinen, T., Jänis, J., Vepsäläinen, J., & Lappalainen, R. (2021) · Molecules · doi:10.3390/molecules26113167 · Cited by 25
Metadata
- Authors
- Smith, D. F., Podgorski, D. C., Rodgers, R. P., Blakney, G. T., & Hendrickson, C. L.
- Venue
- Analytical Chemistry
- Publisher
- American Chemical Society (ACS)
- Published
- 2018-01-05
- Volume
- 90
- Issue
- 3
- Pages
- 2041-2047
- ISSN
- 0003-2700 (ISSN-L)
- 1520-6882
- OpenAlex
- W2782030392
- Cited by
- 348
- References
- 42
- FWCI
- 13.88
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.