Sniffing Entrapped Humans with Sensor Arrays
Open accessThe DOI matches its Crossref record; 2 of the 2 references it cites were found in a registry or an index.
Abstract
Abstract Earthquakes are lethal natural disasters frequently burying people alive under collapsed buildings. Tracking entrapped humans from their unique volatile chemical signature with hand-held devices would accelerate urban search and rescue (USaR) efforts. Here, a pilot study is presented with compact and orthogonal sensor arrays to detect the breath- and skin-emitted metabolic tracers acetone, ammonia, isoprene, CO2, and relative humidity (RH), all together serving as sign of life. It consists of three nanostructured metal-oxide sensors (Si-doped WO3, Si-doped MoO3, and Ti-doped ZnO), each specifically tailored at the nanoscale for highly sensitive and selective tracer detection along with commercial CO2 and humidity sensors. When tested on humans enclosed in plethysmography chambers to simulate entrapment, this sensor array rapidly detected sub-ppm acetone, ammonia, and isoprene concentrations with high accuracies (19, 21, and 3 ppb, respectively) and precision, unprecedented by portable sensors but required for USaR. These results were in good agreement (Pearson’s correlation coefficients ≥0.9) with benchtop selective reagent ionization time-of-flight mass spectrometry (SRI-TOF-MS). As a result, an inexpensive sensor array is presented that can be integrated readily into hand-held or even drone-carried detectors for first responders to rapidly screen affected terrain.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
A review of the volatiles from the healthy human body
de Lacy Costello, B., Amann, A., Al-Kateb, H., Flynn, C., Filipiak, W., Khalid, T., Osborne, D., & Ratcliffe, N. M. (2014) · Journal of Breath Research · doi:10.1088/1752-7155/8/1/014001 · Cited by 1,042
Review on ion mobility spectrometry. Part 1: current instrumentation
Cumeras, R., Figueras, E., Davis, C. E., Baumbach, J. I., & Gràcia, I. (2015) · The Analyst · doi:10.1039/c4an01100g · Cited by 459
Cited by
Supramolecular Luminescent Sensors
Mako, T. L., Racicot, J. M., & Levine, M. (2019) · Chemical Reviews · doi:10.1021/acs.chemrev.8b00260 · Cited by 735
Selectivity in Chemiresistive Gas Sensors: Strategies and Challenges
Bulemo, P. M., Kim, D.-H., Shin, H., Cho, H.-J., Koo, W.-T., Choi, S.-J., Park, C., Ahn, J., Güntner, A. T., Penner, R. M., et al. (2025) · Chemical Reviews · doi:10.1021/acs.chemrev.4c00592 · Cited by 418
Self-citationEvolution of breath analysis based on humidity and gas sensors: Potential and challenges
Tai, H., Wang, S., Duan, Z., & Jiang, Y. (2020) · Sensors and Actuators B: Chemical · doi:10.1016/j.snb.2020.128104 · Cited by 412
Breath Sensors for Health Monitoring
Güntner, A. T., Abegg, S., Königstein, K., Gerber, P. A., Schmidt-Trucksäss, A., & Pratsinis, S. E. (2019) · ACS Sensors · doi:10.1021/acssensors.8b00937 · Cited by 410
Self-citationHighly selective detection of methanol over ethanol by a handheld gas sensor
van den Broek, J., Abegg, S., Pratsinis, S. E., & Güntner, A. T. (2019) · Nature Communications · doi:10.1038/s41467-019-12223-4 · Cited by 378
Self-citation
Metadata
- Authors
- Güntner, A. T., Pineau, N. J., Mochalski, P., Wiesenhofer, H., Agapiou, A., Mayhew, C. A., & Pratsinis, S. E.
- Venue
- Analytical Chemistry
- Publisher
- American Chemical Society (ACS)
- Published
- 2018-03-30
- Volume
- 90
- Issue
- 8
- Pages
- 4940-4945
- ISSN
- 0003-2700 (ISSN-L)
- 1520-6882
- OpenAlex
- W2794728477
- Cited by
- 121
- References
- 2
- FWCI
- 6.70
- Type
- journal article
- Language
- en
- Open access
- hybrid
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: Sniffing Entrapped Humans with Sensor Arrays. https://app.cochat.ai/papers/10.1021/acs.analchem.8b00237
- The paper
- Güntner, A. T., Pineau, N. J., Mochalski, P., Wiesenhofer, H., Agapiou, A., Mayhew, C. A., & Pratsinis, S. E. (2018). Sniffing Entrapped Humans with Sensor Arrays. Analytical Chemistry. https://doi.org/10.1021/acs.analchem.8b00237
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.