The DOI matches its Crossref record; 39 of the 39 references it cites were found in a registry or an index.
Exploration of Nanoparticle-Mediated Photothermal Effect of TMB-H2O2 Colorimetric System and Its Application in a Visual Quantitative Photothermal Immunoassay
Open accessAbstract
The exploration of new physical and chemical properties of materials and their innovative application in different fields are of great importance to advance analytical chemistry, material science, and other important fields. Herein, we, for the first time, discovered the photothermal effect of an iron oxide nanoparticles (NPs)-mediated TMB (3,3′,5,5′-tetramethylbenzidine)-H 2 O 2 colorimetric system, and applied it toward the development of a new NP-mediated photothermal immunoassay platform for visual quantitative biomolecule detection using a thermometer as the signal reader. Using a sandwich-type proof-of-concept immunoassay, we found that the charge transfer complex of the iron oxide NPs-mediated one-electron oxidation product of TMB (oxidized TMB) exhibited not only color changes, but also a strong near-infrared (NIR) laser-driven photothermal effect. Hence, oxidized TMB was explored as a new sensitive photothermal probe to convert the immunoassay signal into heat through the near-infrared laser-driven photothermal effect, enabling simple photothermal immunoassay using a thermometer. Based on the new iron oxide NPs-mediated TMB-H 2 O 2 photothermal immunoassay platform, prostate-specific antigen (PSA) as a model biomarker can be detected at a concentration as low as 1.0 ng·mL –1 in normal human serum. The discovered photothermal effect of the colorimetric system and the developed new photothermal immunoassay platform open up a new horizon for affordable detection of disease biomarkers and have great potential for other important material and biomedical applications of interest.
Overview
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
In Vivo Near-Infrared Mediated Tumor Destruction by Photothermal Effect of Carbon Nanotubes
Moon, H. K., Lee, S. H., & Choi, H. C. (2009) · ACS Nano · doi:10.1021/nn900904h · Cited by 797
Zheng, M., Yue, C., Ma, Y., Gong, P., Zhao, P., Zheng, C., Sheng, Z., Zhang, P., Wang, Z., & Cai, L. (2013) · ACS Nano · doi:10.1021/nn400334y · Cited by 795
Yang, K., Xu, H., Cheng, L., Sun, C., Wang, J., & Liu, Z. (2012) · Advanced Materials · doi:10.1002/adma.201202625 · Cited by 749
Huang, P., Lin, J., Li, W., Rong, P., Wang, Z., Wang, S., Wang, X., Sun, X., Aronova, M., Niu, G., et al. (2013) · Angewandte Chemie International Edition · doi:10.1002/anie.201308986 · Cited by 672
Xia, F., Zuo, X., Yang, R., Xiao, Y., Kang, D., Vallée-Bélisle, A., Gong, X., Yuen, J. D., Hsu, B. B. Y., Heeger, A. J., et al. (2010) · Proceedings of the National Academy of Sciences · doi:10.1073/pnas.1005632107 · Cited by 539
Nanosecond Photothermal Effects in Plasmonic Nanostructures
Chen, X., Chen, Y., Yan, M., & Qiu, M. (2012) · ACS Nano · doi:10.1021/nn2050032 · Cited by 415
Fu, G., Liu, W., Feng, S., & Yue, X. (2012) · Chemical Communications · doi:10.1039/c2cc36456e · Cited by 350
Self-citationKe, H., Wang, J., Dai, Z., Jin, Y., Qu, E., Xing, Z., Guo, C., Yue, X., & Liu, J. (2011) · Angewandte Chemie International Edition · doi:10.1002/anie.201008286 · Cited by 327
Point-of-care biochemical assays using gold nanoparticle-implemented microfluidics
Sun, J., Xianyu, Y., & Jiang, X. (2014) · Chem. Soc. Rev. · doi:10.1039/c4cs00125g · Cited by 323
Yang, J., Shen, D., Zhou, L., Li, W., Li, X., Yao, C., Wang, R., El-Toni, A. M., Zhang, F., & Zhao, D. (2013) · Chemistry of Materials · doi:10.1021/cm401115b · Cited by 321
Self-citationTwo-dimensional Layered MoS2 Biosensors Enable Highly Sensitive Detection of Biomolecules
Lee, J., Dak, P., Lee, Y., Park, H., Choi, W., Alam, M. A., & Kim, S. (2014) · Scientific Reports · doi:10.1038/srep07352 · Cited by 318
Liu, P., Yang, X., Sun, S., Wang, Q., Wang, K., Huang, J., Liu, J., & He, L. (2013) · Analytical Chemistry · doi:10.1021/ac4001157 · Cited by 302
Zheng, X., Xing, D., Zhou, F., Wu, B., & Chen, W. R. (2011) · Molecular Pharmaceutics · doi:10.1021/mp100301t · Cited by 301
Cheng, L., He, W., Gong, H., Wang, C., Chen, Q., Cheng, Z., & Liu, Z. (2013) · Advanced Functional Materials · doi:10.1002/adfm.201301045 · Cited by 277
Biomarker detection for disease diagnosis using cost-effective microfluidic platforms
Sanjay, S. T., Fu, G., Dou, M., Xu, F., Liu, R., Qi, H., & Li, X. (2015) · The Analyst · doi:10.1039/c5an00780a · Cited by 267
Self-citationChen, Q., Wang, C., Zhan, Z., He, W., Cheng, Z., Li, Y., & Liu, Z. (2014) · Biomaterials · doi:10.1016/j.biomaterials.2014.06.013 · Cited by 226
Green Synthesis of Anisotropic Gold Nanoparticles for Photothermal Therapy of Cancer
Fazal, S., Jayasree, A., Sasidharan, S., Koyakutty, M., Nair, S. V., & Menon, D. (2014) · ACS Applied Materials & Interfaces · doi:10.1021/am500302t · Cited by 208
A Versatile PDMS/Paper Hybrid Microfluidic Platform for Sensitive Infectious Disease Diagnosis
Dou, M., Dominguez, D. C., Li, X., Sanchez, J., & Scott, G. (2014) · Analytical Chemistry · doi:10.1021/ac5021694 · Cited by 205
Self-citationMultiplexed protein detection by proximity ligation for cancer biomarker validation
Fredriksson, S., Dixon, W., Ji, H., Koong, A. C., Mindrinos, M., & Davis, R. W. (2007) · Nature Methods · doi:10.1038/nmeth1020 · Cited by 196
Gao, Z., Hou, L., Xu, M., & Tang, D. (2014) · Scientific Reports · doi:10.1038/srep03966 · Cited by 161
Low-cost bioanalysis on paper-based and its hybrid microfluidic platforms
Dou, M., Sanjay, S. T., Benhabib, M., Xu, F., & Li, X. (2015) · Talanta · doi:10.1016/j.talanta.2015.04.068 · Cited by 150
Self-citationFu, G., Liu, W., Li, Y., Jin, Y., Jiang, L., Liang, X., Feng, S., & Dai, Z. (2014) · Bioconjugate Chemistry · doi:10.1021/bc500279w · Cited by 143
Self-citationSanjay, S. T., Dou, M., Sun, J., et al. (2016) · Scientific Reports · doi:10.1038/srep30474 · Cited by 128
Self-citationMultiplexed instrument-free meningitis diagnosis on a polymer/paper hybrid microfluidic biochip
Dou, M., Sanjay, S. T., Domínguez, D. C., Liu, P., Xu, F., & Li, X. (2016) · Biosensors and Bioelectronics · doi:10.1016/j.bios.2016.09.033 · Cited by 124
Self-citationActivated photothermal heating using croconaine dyes
Spence, G. T., Hartland, G. V., & Smith, B. D. (2013) · Chemical Science · doi:10.1039/c3sc51978c · Cited by 117
Zou, F., Zhou, H., Tan, T. V., Kim, J., Koh, K., & Lee, J. (2015) · ACS Applied Materials & Interfaces · doi:10.1021/acsami.5b02523 · Cited by 116
Lv, R., Zhong, C., Li, R., et al. (2015) · Chemistry of Materials · doi:10.1021/cm504566f · Cited by 115
Li, J., Wang, W., Zhao, L., Rong, L., Lan, S., Sun, H., Zhang, H., & Yang, B. J. (2015) · ACS Applied Materials & Interfaces · doi:10.1021/acsami.5b02666 · Cited by 114
Shan, G., Weissleder, R., & Hilderbrand, S. A. (2013) · Theranostics · doi:10.7150/thno.5226 · Cited by 109
Petryayeva, E., & Algar, W. R. (2015) · RSC Advances · doi:10.1039/c4ra15036h · Cited by 107
Krishna, K. S., Zhang, J., Castro, E., Bernal, R. A., & Li, X. (2017) · ACS Applied Materials & Interfaces · doi:10.1021/acsami.7b12614 · Cited by 101
Self-citationBahmani, B., Bacon, D., & Anvari, B. (2013) · Scientific Reports · doi:10.1038/srep02180 · Cited by 100
A Homogeneous Chemiluminescent Immunoassay Method
Akhavan-Tafti, H., Binger, D. G., Blackwood, J., Chen, Y., Creager, R. S., de Silva, R., Eickholt, R. A., Gaibor, J. E., Handley, R. S., Kapsner, K. P., et al. (2013) · Journal of the American Chemical Society · doi:10.1021/ja312039k · Cited by 78
Woo, M., Kim, M. I., Jung, J. W., Park, K. S., Seo, T., & Park, H. G. (2013) · International Journal of Molecular Sciences · doi:10.3390/ijms14059999 · Cited by 71
Lin, M., Wang, D., Liu, S., Huang, T., Sun, B., Cui, Y., Zhang, D., Sun, H., Zhang, H., Sun, H., et al. (2015) · ACS Applied Materials & Interfaces · doi:10.1021/acsami.5b05866 · Cited by 69
Liu, J., Lu, C.-Y., Zhou, H., Xu, J., Wang, Z., & Chen, H. (2013) · Chemical Communications · doi:10.1039/c3cc43532f · Cited by 67
Guerreiro, J. R. L., Frederiksen, M., Bochenkov, V. E., de Freitas, V. A. P., Sales, M. G. F., & Sutherland, D. S. (2014) · ACS Nano · doi:10.1021/nn501962y · Cited by 65
Qin, X., Xu, A., Liu, L., Deng, W., Chen, C., Tan, Y., Fu, Y., Xie, Q., & Yao, S. (2015) · Chemical Communications · doi:10.1039/c5cc01439e · Cited by 43
Surface plasmon resonance-based immunoassay for human fetuin A
Vashist, S. K., Schneider, E. M., & Luong, J. H. T. (2014) · The Analyst · doi:10.1039/c4an00149d · Cited by 36
Cited by
Recent advances in nanomaterials for enhanced photothermal therapy of tumors
Hu, J.-J., Cheng, Y.-J., & Zhang, X.-Z. (2018) · Nanoscale · doi:10.1039/c8nr07627h · Cited by 409
Cai, G., Yu, Z., Tong, P., & Tang, D. (2019) · Nanoscale · doi:10.1039/c9nr05797h · Cited by 339
Aptamer-functionalized metal-organic frameworks (MOFs) for biosensing
Lv, M., Zhou, W., Tavakoli, H., Bautista, C., Xia, J., Wang, Z., & Li, X. (2021) · Biosensors and Bioelectronics · doi:10.1016/j.bios.2020.112947 · Cited by 331
Self-citationHuang, L., Chen, J., Yu, Z., & Tang, D. (2020) · Analytical Chemistry · doi:10.1021/acs.analchem.9b05218 · Cited by 320
Liu, C., Zhang, W., Li, Y., Chang, J., Tian, F., Zhao, F., Ma, Y., & Sun, J. (2019) · Nano Letters · doi:10.1021/acs.nanolett.9b02841 · Cited by 267
Metadata
- Authors
- Fu, G., Sanjay, S. T., Zhou, W., Brekken, R. A., Kirken, R. A., & Li, X.
- Venue
- Analytical Chemistry
- Publisher
- American Chemical Society (ACS)
- Published
- 2018-04-11
- Volume
- 90
- Issue
- 9
- Pages
- 5930-5937
- ISSN
- 0003-2700 (ISSN-L)
- 1520-6882
- OpenAlex
- W2796620311
- Cited by
- 273
- References
- 39
- FWCI
- 11.04
- Type
- journal article
- Language
- en
- Open access
- green
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.