A Ratiometric Fluorescent Bioprobe Based on Carbon Dots and Acridone Derivate for Signal Amplification Detection Exosomal microRNA

Xia, Yaokun, Wang, Liangliang, Li, Juan, Chen, Xiangqi, Lan, Jianming, Yan, An, Lei, Yun, Yang, Sheng, Yang, Huanghao, Chen, Jinghua · 2018 · Analytical Chemistry

Abstract

Recently, sensitive and selective detection of exosomal microRNAs (miRNAs) has been garnering significant attention, because it is related to many complex diseases, including cancer. Herein, we report a ratiometric fluorescent bioprobe based on DNA-labeled carbon dots (DNA-CDs) and 5,7-dinitro-2-sulfo-acridone (DSA) coupling with the target-catalyzing signal amplification for the detection of exosomal miRNA-21. There was high fluorescence resonance energy transfer (FRET) efficiency between carbon dots (CDs) and DSA when the bioprobe was assembled. However, in the presence of the target, with disassembling of the fluorescent bioprobe, the fluorescence intensities of CDs and DSA were changed simultaneously. Because of the ratio of dual fluorescence intensities, this ratiometric fluorescent bioprobe was able to cancel out environmental fluctuations by calculating emission intensity ratio at two different wavelengths, being robust and stable enough for detection of exosomal miRNA-21. In addition, we displayed that a single miRNA-21 can catalyze the disassembly of multiple CDs with DSA theoretically, yielding significant change in the fluorescence ratio for the detection of miRNA-21. With this signal amplification strategy, the limit of detection was as low as 3.0 fM. Furthermore, because of the introduction of lock nucleic acid to mediate the strand displacement reaction, the selectivity of this strategy was improved remarkably, even against single base mismatch sequence. More importantly, our strategy could monitor the dynamic change of exosomal miRNA-21, which maybe becomes a potential tool to distinguish cancer exosomes and nontumorigenic exosomes. In a short, this ratiometric fluorescence bioprobe possessed high stability, sensitivity and selectivity coupling with ease of operation and cost efficiency, leading to great potential for wide application.

Overview

The claims and statistics of this paper haven’t been checked yet.

Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.

A few free checks a day · papers already verified open instantly · results are public

Integrity signals

Registry

Crossref · 10.1021/acs.analchem.8b01143

Cites

2 of 2 references verified0 citation errors · 0 not checkable

Statistics

Verification

Claims the paper makes

The claims and statistics of this paper haven’t been checked yet.

Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.

A few free checks a day · papers already verified open instantly · results are public

Self-check

Percentages, sums and reported differences re-computed from the paper’s own numbers.

The self-check needs the paper’s full text.

Citations

Cites

Cited by

See all 175

Metadata

Authors
Xia, Y., Wang, L., Li, J., Chen, X., Lan, J., Yan, A., Lei, Y., Yang, S., Yang, H., & Chen, J.
Venue
Analytical Chemistry
Published
2018-07-05
Volume
90
Issue
15
Pages
8969-8976
ISSN
  • 0003-2700 (ISSN-L)
  • 1520-6882
OpenAlex
W2821214667
Cited by
175
References
2
FWCI
7.77
Type
journal article
Language
en
Open access
closed

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review

Data sources

Bibliographic data: Semantic Scholar, OpenAlex, Crossref.

Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).

Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.