The DOI matches its Crossref record.
Platinum Nanozyme-Catalyzed Gas Generation for Pressure-Based Bioassay Using Polyaniline Nanowires-Functionalized Graphene Oxide Framework
Abstract
Pressure-based bioassays incorporating biomolecular recognition with a catalyzed gas-generation reaction have been developed for gas biosensors, but most involve poor sensitivity and are unsuitable for routine use. Herein we design an innovative gas pressure-based biosensing platform for the detection of Kanamycin (Kana) on polyaniline nanowires-functionalized reduced graphene oxide (PANI/rGO) framework by using platinum nanozyme-catalyzed gas generation. The signal was amplified by coupling with catalytic hairpin assembly (CHA) and strand-displacement amplification (SDA). Upon target Kana introduction, the analyte initially triggered a SDA reaction between hairpin DNA1 and hairpin DNA2, and then induced CHA conjugation between magnetic bead-labeled hairpin DNA3 (MB-H3) and platinum nanoparticle-labeled hairpin DNA4 (Pt-H4) to form a three-dimensional network. Numerous platinum nanoparticles (peroxidase-like nanozymes) were carried over with magnetic beads to reduce hydrogen peroxide into oxygen. The as-produced gas compressed PANI/rGO frameworks (modified to polyurethane sponge, used as the piezoelectric materials) in a homemade pressure-tight device, thus causing the increasing current of PANI/rGO sponge thanks to its deformation. The change in the current caused by the as-generated gas pressure was determined on an electrochemical workstation. Under optimum conditions, PANI/rGO sponge exhibited outstanding compressibility, stable signal-waveform output, fast response and recovery time (≈109 ms), and the current increased with the increasing Kana concentration within a dynamic working range of 0.2-50 pM at a detection limit of 0.063 pM. Good reproducibility, specificity, and acceptable precision were acquired for Kana analysis. In addition, the accuracy of this method was monitored to evaluate real milk samples with the well-matched results obtained by using the referenced Kana ELISA kit.
Overview
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cited by
CRISPR-Cas12a-Derived Photoelectrochemical Biosensor for Point-Of-Care Diagnosis of Nucleic Acid
Zeng, R., Gong, H., Li, Y., Li, Y., Lin, W., Tang, D., & Knopp, D. (2022) · Analytical Chemistry · doi:10.1021/acs.analchem.2c01373 · Cited by 404
Self-citationCRISPR-Cas12a-driven MXene-PEDOT:PSS piezoresistive wireless biosensor
Zeng, R., Wang, W., Chen, M., Wan, Q., Wang, C., Knopp, D., & Tang, D. (2021) · Nano Energy · doi:10.1016/j.nanoen.2020.105711 · Cited by 394
Self-citationRecent advances in noninvasive flexible and wearable wireless biosensors
Salim, A., & Lim, S. (2019) · Biosensors and Bioelectronics · doi:10.1016/j.bios.2019.111422 · Cited by 153
Metadata
- Authors
- Zeng, R., Luo, Z., Zhang, L., & Tang, D.
- Venue
- Analytical Chemistry
- Publisher
- American Chemical Society (ACS)
- Published
- 2018-09-17
- Volume
- 90
- Issue
- 20
- Pages
- 12299-12306
- ISSN
- 0003-2700 (ISSN-L)
- 1520-6882
- OpenAlex
- W2891119917
- Cited by
- 355
- References
- 0
- FWCI
- 12.01
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: Platinum Nanozyme-Catalyzed Gas Generation for Pressure-Based Bioassay Using Polyaniline Nanowires-Functionalized Graphene Oxide Framework. https://app.cochat.ai/papers/10.1021/acs.analchem.8b03889
- The paper
- Zeng, R., Luo, Z., Zhang, L., & Tang, D. (2018). Platinum Nanozyme-Catalyzed Gas Generation for Pressure-Based Bioassay Using Polyaniline Nanowires-Functionalized Graphene Oxide Framework. Analytical Chemistry. https://doi.org/10.1021/acs.analchem.8b03889
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.