Student or educator? Sign up with your school email and get 6 months of Pro free.
Cited by 394

The DOI matches its Crossref record; 34 of the 34 references it cites were found in a registry or an index.

CRISPR-Cas12a-driven MXene-PEDOT:PSS piezoresistive wireless biosensor

Zeng, Ruijin, Wang, Weijun, Chen, Mingming, Wan, Qing, Wang, Caicheng, Knopp, Dietmar, Tang, Dianping·2021·Nano Energy

Abstract

Abstract Beyond extraordinary in vivo accurate gene editing and regulation capabilities, the CRISPR-Cas-associated biotechnology has created a new era of in vitro nucleic acid sensing due to its inherent high-efficiency enzyme cleavage activity and robustness. However, most of the existing CRISPR-Cas systems are largely involve fluorescent reporters or lateral flow strips biosensor and can't fully explore their potential applications (sensitivity and field-deployable) due to the lack of effective signal transduction and wireless data transmission with smartphone readout. Herein, a CRISPR-Cas12a-mediated instrument-free based on flexible interdigitated electrodes-modified piezoresistive block [abrasive paper-molded microstructure polydimethylsiloxane (PDMS) and MXene (Ti3C2Tx)-PEDOT:PSS film] was designed for point-of-care of human papillomavirus (HPV)-related DNA with integrated-module smartphone visual readout. Biotin/thiol-modification single-stranded DNA (ssDNA), acts as a linker between Au@Pt nanoparticles (Au@PtNPs) and streptavidin-coated magnetic bead (MB), are non-specifically cleaved by Cas12a when the guide RNA binds to the target HPV-DNA. Released and separated Au@PtNPs efficiently catalyzes H2O2 to O2, and further compress the Ti3C2Tx-PEDOT:PSS/PDMS in a 3D-printed home-made pressure-tight vessel, thus causing the increasing current of the whole circuit thanks to contacting deformation of Ti3C2Tx-PEDOT:PSS/PDMS module and interdigital electrode. After integrating the Bluetooth device and wireless sensing technology in the circuit, the current signal of the target DNA can be wirelessly collected and recorded in real-time and further transmitted/displayed to the mobile terminal of the smartphone. This all-in-one detection mode not only bridges the technological gap between biological signal conduction, wireless transmission, and smartphone interface but also improves the portability and the sensitivity (more than one order of magnitude lower than that of traditional CRISPR-Cas12a biosensors). We expect that a powerful CRISPR-Cas12a system coupled with piezoresistive sensor with wireless transmission technology will become a great demonstration and widely used in real-time wireless biomedical analysis, portable point-of-care health monitoring, and molecular diagnostics.

Overview

The claims and statistics of this paper haven’t been checked yet.

Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.

A few free checks a day · papers already verified open instantly · results are public

Integrity signals

Registry

Crossref · 10.1016/j.nanoen.2020.105711

Cites

34 of 34 references verified0 citation errors · 0 not checkable

Statistics

Verification

Claims the paper makes

The claims and statistics of this paper haven’t been checked yet.

Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.

A few free checks a day · papers already verified open instantly · results are public

Self-check

Percentages, sums and reported differences re-computed from the paper’s own numbers.

The self-check needs the paper’s full text.

Citations

Cites

Show all 34 references

Cited by

See all 394

Metadata

Authors
Zeng, R., Wang, W., Chen, M., Wan, Q., Wang, C., Knopp, D., & Tang, D.
Venue
Nano Energy
Publisher
Elsevier BV
Published
2021-04
Volume
82
Pages
105711
ISSN
2211-2855 (ISSN-L)
OpenAlex
W3112329071
Cited by
394
References
34
FWCI
16.87
Type
journal article
Language
en
Open access
closed

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review

How to cite

Cite CoChat for the checks on this page, and the paper for its own findings.

This page
CoChat. (2026). Citation check: CRISPR-Cas12a-driven MXene-PEDOT:PSS piezoresistive wireless biosensor. https://app.cochat.ai/papers/10.1016/j.nanoen.2020.105711
The paper
Zeng, R., Wang, W., Chen, M., Wan, Q., Wang, C., Knopp, D., & Tang, D. (2021). CRISPR-Cas12a-driven MXene-PEDOT:PSS piezoresistive wireless biosensor. Nano Energy. https://doi.org/10.1016/j.nanoen.2020.105711

Data sources

Bibliographic data: Semantic Scholar, OpenAlex, Crossref.

Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).

Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.