A Middle-Up Approach with Online Capillary Isoelectric Focusing/Mass Spectrometry for In-Depth Characterization of Cetuximab Charge Heterogeneity
The DOI matches its Crossref record; 49 of the 49 references it cites were found in a registry or an index.
Abstract
Previously, we reported a new online capillary isoelectric focusing/mass spectrometric (CIEF/MS) method for intact monoclonal antibody (mAb) charge variant analysis that uses an electrokinetically pumped sheath-flow nanospray ion source on a time-of-flight (TOF) MS with a pressure-assisted chemical mobilization. The direct online CIEF/MS method exhibited excellent resolution of charge variants conforming to those of imaged capillary isoelectric focusing with ultraviolet detection (iCIEF/UV). However, for complex mAbs, CIEF/MS spectra of the intact charge variant peaks may be too convoluted to be effectively interpreted. In the present study, we implemented a middle-up approach to enhance the capability of the CIEF/MS method for characterizing complex mAb charge variants by reducing sample complexity. To demonstrate such a strategy, we fragmented cetuximab through IdeS enzymatic cleavage and dithiothreitol (DTT) reduction. For the first time, online CIEF/MS resolved the complex charge variants of cetuximab at subunit level, corroborating the profiles obtained by iCIEF/UV. Furthermore, high-resolution TOF mass spectra with high mass accuracy were obtained for the eight charge variants separated by CIEF/MS after IdeS cleavage and for the 11 charge variants after IdeS digestion with subsequent DTT reduction. In-depth analyses revealed the identities of all charge variants and pinpointed the causes of charge heterogeneity, which are in accord with those reported in the literature. The main sources of charge heterogeneity of cetuximab were identified as terminal lysine on the Fc domain (up to one on each single-chain Fc), glycolylneuraminic acid residues on the Fd' domain (up to two on each Fd'), and likely several deamidation species on the Fd' domain. No charge heterogeneity contribution was found from light chain. The in-depth characterization of complex charge variants for cetuximab demonstrates the remarkable capability of this middle-up CIEF/MS approach. This novel workflow holds great potential for detecting and elucidating charge variants to help understand proteins with complex charge heterogeneity.
Overview
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
Claims other papers make about this one
Each is checked against this paper’s own text: does it say what the citing paper says it does?
In the citing paper
“In another report, Dai and Zhang used cIEF with a middle-down strategy to reduce sample complexity to achieve characterization of the charge heterogeneity for the same monoclonal antibody93.”
From Recent trends of capillary electrophoresis‐mass spectrometry in proteomics research (2019) · cites this paper as [93]
Citations
Cites
IdeS, a novel streptococcal cysteine proteinase with unique specificity for immunoglobulin G
von Pawel-Rammingen, U. (2002) · The EMBO Journal · doi:10.1093/emboj/21.7.1607 · Cited by 473
Qian, J., Liu, T., Yang, L., Daus, A., Crowley, R., & Zhou, Q. (2007) · Analytical Biochemistry · doi:10.1016/j.ab.2007.01.023 · Cited by 291
Vlasak, J., Bussat, M. C., Wang, S., Wagner-Rousset, E., Schaefer, M., Klinguer-Hamour, C., Kirchmeier, M., Corvaïa, N., Ionescu, R., & Beck, A. (2009) · Analytical Biochemistry · doi:10.1016/j.ab.2009.05.043 · Cited by 252
Biosimilar, Biobetter, and Next Generation Antibody Characterization by Mass Spectrometry
Beck, A., Sanglier-Cianférani, S., & Van Dorsselaer, A. (2012) · Analytical Chemistry · doi:10.1021/ac3002885 · Cited by 247
Ayoub, D., Jabs, W., Resemann, A., Evers, W., Evans, C., Main, L., Baessmann, C., Wagner-Rousset, E., Suckau, D., & Beck, A. (2013) · mAbs · doi:10.4161/mabs.25423 · Cited by 184
Asparagine Deamidation Dependence on Buffer Type, pH, and Temperature
Pace, A. L., Wong, R. L., Zhang, Y. T., Kao, Y.-H., & Wang, Y. J. (2013) · Journal of Pharmaceutical Sciences · doi:10.1002/jps.23529 · Cited by 159
Self-citationAn, Y., Zhang, Y., Mueller, H.-M., Shameem, M., & Chen, X. (2014) · mAbs · doi:10.4161/mabs.28762 · Cited by 143
Self-citationFüssl, F., Cook, K., Scheffler, K., Farrell, A., Mittermayr, S., & Bones, J. (2018) · Analytical Chemistry · doi:10.1021/acs.analchem.7b05241 · Cited by 132
Toward an Optimized Workflow for Middle-Down Proteomics
Cristobal, A., Marino, F., Post, H., van den Toorn, H. W. P., Mohammed, S., & Heck, A. J. R. (2017) · Analytical Chemistry · doi:10.1021/acs.analchem.6b03756 · Cited by 130
A protease for 'middle-down' proteomics
Wu, C., Tran, J. C., Zamdborg, L., Durbin, K. R., Li, M., Ahlf, D. R., Early, B. P., Thomas, P. M., Sweedler, J. V., & Kelleher, N. L. (2012) · Nature Methods · doi:10.1038/nmeth.2074 · Cited by 128
Cited by
Monitoring of immunoglobulin N- and O-glycosylation in health and disease
de Haan, N., Falck, D., & Wuhrer, M. (2019) · Glycobiology · doi:10.1093/glycob/cwz048 · Cited by 128
“Examples of enzymes used in these approaches are IdeS, which is expected to result in two Fc/2 fragments and one intact F(ab’)2 fragment by cleaving IgG under the hinge region, and GingisKHAN which results in one intact Fc and two intact Fab fragments by cleaving IgG above the hinge region (van der Burgt et al. 2019).”
BackgroundInfluentialRecent trends of capillary electrophoresis‐mass spectrometry in proteomics research
Gomes, F. P., & Yates, J. R. (2019) · Mass Spectrometry Reviews · doi:10.1002/mas.21599 · Cited by 112
Recent advances (2019–2021) of capillary electrophoresis‐mass spectrometry for multilevel proteomics
Chen, D., McCool, E. N., Yang, Z., Shen, X., Lubeckyj, R. A., Xu, T., Wang, Q., & Sun, L. (2021) · Mass Spectrometry Reviews · doi:10.1002/mas.21714 · Cited by 106
Füssl, F., Trappe, A., Carillo, S., Jakes, C., & Bones, J. (2020) · Analytical Chemistry · doi:10.1021/acs.analchem.0c00185 · Cited by 95
Camperi, J., Goyon, A., Guillarme, D., Zhang, K., & Stella, C. (2020) · The Analyst · doi:10.1039/d0an01963a · Cited by 87
Challenging Bioanalyses with Capillary Electrophoresis
Kristoff, C. J., Bwanali, L., Veltri, L. M., Gautam, G. P., Rutto, P. K., Newton, E. O., & Holland, L. (2019) · Analytical Chemistry · doi:10.1021/acs.analchem.9b04718 · Cited by 81
Lechner, A., Giorgetti, J., Gahoual, R., Beck, A., Leize‐Wagner, E., & François, Y. (2019) · Journal of Chromatography B · doi:10.1016/j.jchromb.2019.05.014 · Cited by 82
“MS detection represents a key feature for future developments to improve 250 the performance of cIEF and icIEF in terms of sensitivity and structural characterization [66-68].”
MethodApplications of capillary electrophoresis for biopharmaceutical product characterization
Kumar, R., Guttman, A., & Rathore, A. S. (2022) · ELECTROPHORESIS · doi:10.1002/elps.202100182 · Cited by 58
Giorgetti, J., Beck, A., Leize‐Wagner, E., & François, Y. (2020) · Journal of Pharmaceutical and Biomedical Analysis · doi:10.1016/j.jpba.2020.113107 · Cited by 61
“highlight the importance of multi-level characterization of mAbs [25-27].”
BackgroundDadouch, M., Ladner, Y., & Perrin, C. (2021) · Separations · doi:10.3390/separations8010004 · Cited by 53
A Mini Review on Capillary Isoelectric Focusing-Mass Spectrometry for Top-Down Proteomics
Xu, T., & Sun, L. (2021) · Frontiers in Chemistry · doi:10.3389/fchem.2021.651757 · Cited by 42
“, cetuximab), leading to the identification of at least eight different charge variants of cetuximab (Dai and Zhang, 2018).”
BackgroundJin, Y., Yi, Y., & Yeung, B. (2020) · Methods · doi:10.1016/j.ymeth.2020.08.002 · Cited by 50
Xu, T., Han, L., Thompson, A. M. G., & Sun, L. (2021) · Analytical Methods · doi:10.1039/d1ay01556g · Cited by 41
Farsang, E., Murisier, A., Horváth, K., Beck, A., Kormány, R., Guillarme, D., & Fekete, S. (2019) · Journal of Pharmaceutical and Biomedical Analysis · doi:10.1016/j.jpba.2019.02.024 · Cited by 41
Schlecht, J., Moritz, B., Kiessig, S., & Neusüß, C. (2022) · Electrophoresis · doi:10.1002/elps.202200170 · Cited by 38
Recent progress in the analysis of protein deamidation using mass spectrometry
Ying, Y., & Li, H. (2020) · Methods · doi:10.1016/j.ymeth.2020.06.009 · Cited by 42
Watts, E., Williams, J. D., Miesbauer, L. J., Bruncko, M., & Brodbelt, J. S. (2020) · Analytical Chemistry · doi:10.1021/acs.analchem.0c01232 · Cited by 31
Wang, L., & Chen, D. D. Y. (2019) · Electrophoresis · doi:10.1002/elps.201900195 · Cited by 26
Liu, A. P., Yan, Y., Wang, S., & Li, N. (2022) · Analytical Chemistry · doi:10.1021/acs.analchem.2c00707 · Cited by 24
Capillary electrophoresis as a sample separation step to mass spectrometry analysis: A primer
Lapizco‐Encinas, B. H., Zhang, Y. V., Gqamana, P. P., Lavická, J., & Foret, F. (2023) · TrAC Trends in Analytical Chemistry · doi:10.1016/j.trac.2023.117093 · Cited by 29
Self-citationKristoff, C. J., Li, C., Li, P., & Holland, L. (2020) · Analytical Chemistry · doi:10.1021/acs.analchem.9b03994 · Cited by 21
Naghdi, E., Reinau, M. E., Krogh, T. N., & Neusüß, C. (2024) · Analytical Chemistry · doi:10.1021/acs.analchem.4c02441 · Cited by 14
Schairer, J., Höchsmann, A., Bauer, B., Höfer, V., Römer, J., & Neusüß, C. (2025) · mAbs · doi:10.1080/19420862.2025.2537116 · Cited by 14
“CIEF was used for subunit analysis of cetuximab, 101 but apart from that, CIEF is commonly used for the intact analysis of mAbs.”
Schmailzl, J., Vorage, M. W., & Stutz, H. (2020) · Electrophoresis · doi:10.1002/elps.202000013 · Cited by 13
Nagy, C., Andrási, M., Hamidli, N., Gyémánt, G., & Gáspár, A. (2021) · Journal of Chromatography Open · doi:10.1016/j.jcoa.2021.100024 · Cited by 12
Stability-Indicating Size Exclusion Chromatography Method for the Analysis of IgG mAb-Cetuximab
Farjami, A., Akbarzadehlaleh, P., Molavi, O., & Siahi‐Shadbad, M. (2019) · Chromatographia · doi:10.1007/s10337-019-03703-2 · Cited by 11
Dadouch, M., Ladner, Y., Bich, C., Montels, J., Morel, J., Bechara, C., & Perrin, C. (2021) · Journal of Chromatography A · doi:10.1016/j.chroma.2021.462213 · Cited by 12
Trappe, A., Füssl, F., Millán‐Martín, S., Ronan, R., Zaborowska, I., & Bones, J. (2022) · Journal of Chromatography B · doi:10.1016/j.jchromb.2022.123186 · Cited by 10
Gilardoni, E., & Regazzoni, L. (2022) · Journal of Chromatography Open · doi:10.1016/j.jcoa.2022.100034 · Cited by 9
Mass spectrometry-based analysis of IgG glycosylation and its applications
Liu, X., Sun, Z., Li, Z., Zhang, Y., & Lu, H. (2022) · International Journal of Mass Spectrometry · doi:10.1016/j.ijms.2022.116799 · Cited by 11
Self-citationHitting the sweet spot with capillary electrophoresis: advances in N-glycomics and glycoproteomics
Makrydaki, E., Kotidis, P., Polizzi, K. M., & Kontoravdi, C. (2021) · Current Opinion in Biotechnology · doi:10.1016/j.copbio.2021.07.013 · Cited by 8
Schairer, J., Römer, J., & Neusüß, C. (2024) · Journal of Pharmaceutical and Biomedical Analysis · doi:10.1016/j.jpba.2024.116495 · Cited by 7
Beloborodov, S. S., Schneider, B. B., Oleschuk, R. D., & Blanc, J. C. Y. L. (2023) · Journal of the American Society for Mass Spectrometry · doi:10.1021/jasms.3c00060 · Cited by 6
Madren, S. M., & Yi, L. (2022) · Electrophoresis · doi:10.1002/elps.202200129 · Cited by 6
Kaya, S. I., Çetinkaya, A., Çağlayan, M. G., & Özkan, S. A. (2021) · Electrophoresis · doi:10.1002/elps.202100193 · Cited by 5
Dai, J., Xia, Q., & Ji, C. (2022) · Methods in molecular biology · doi:10.1007/978-1-0716-2325-1_6 · Cited by 5
Self-citationTie, C., Liu, L., Feng, T., Sa, R., Xia, Q., Liang, H., & Mao, Y. (2020) · Journal of Proteomics · doi:10.1016/j.jprot.2020.103676 · Cited by 5
Wang, L., Wu, H. Y., Cao, T., Li, H., Shen, P., Lu, L., & Zhang, Z. (2024) · European Journal of Pharmaceutics and Biopharmaceutics · doi:10.1016/j.ejpb.2024.114248 · Cited by 4
Sharma, R., Gupta, S., & Rathore, A. S. (2024) · Journal of Chromatography A · doi:10.1016/j.chroma.2024.464806 · Cited by 4
Li, M., Zhao, X., Wu, G., Wang, W., Du, J., Xu, G., Duan, M., Fu, Z., Yu, C., & Wang, L. (2024) · Electrophoresis · doi:10.1002/elps.202300258 · Cited by 3
“We took 100 µ g of the sample and added 2 µ L of IdeS protease [22–24], incubating the sample at 37 ◦ C for 30 min.”
HPLC- and CE-based methods for the characterization of therapeutic glycoproteins
Butré, C. I., & Delobel, A. (2021) · Elsevier eBooks · doi:10.1016/b978-0-12-821447-3.00014-7 · Cited by 4
CE–MS Methods for the Characterization of Monoclonal Antibodies
Reinert, T., Beck, A., Houzé, P., Gahoual, R., & François, Y. (2022) · Wiley eBooks · doi:10.1002/9783527833092.ch11 · Cited by 3
Capillary electrophoresis of glycoproteins
Puerta, A., Gomez-Ruiz, L., Díez‐Masa, J. C., & de Frutos, M. (2021) · Elsevier eBooks · doi:10.1016/b978-0-12-821447-3.00009-3 · Cited by 1
Giorgetti, J. (2019) · theses.fr (ABES) · doi:10.70675/706cdd43zdd95z4f0dz8b0cz49421d515990 · Cited by 1
Dadouch, M. (2020) · theses.fr (ABES) · doi:10.70675/f003c2c2z07e0z4998zbd14zada08cd1ae13
Geng, H., Tang, L., Zeng, Y., Yang, B., Fei, M., Zhang, L., & Hsu, S. (2026) · Journal of Chromatography A · doi:10.1016/j.chroma.2026.467501
Metadata
- Authors
- Dai, J., & Zhang, Y.
- Affiliations
- Bristol-Myers Squibb (United States) (US)
- Corresponding author
- Dai, Jun
- Venue
- Analytical Chemistry
- Publisher
- American Chemical Society (ACS)
- Published
- 2018-11-19
- Volume
- 90
- Issue
- 24
- Pages
- 14527-14534
- ISSN
- 0003-2700 (ISSN-L)
- 1520-6882
- OpenAlex
- W2900473322
- Cited by
- 46
- References
- 49
- Citations by year
- 2026: 1 · 2025: 1 · 2024: 5 · 2023: 2 · 2022: 8 · 2021: 11 · 2020: 10 · 2019: 8
- FWCI
- 3.13
- Type
- journal article
- Language
- en
- Open access
- closed
- Locations
- Analytical Chemistry (publishedVersion)
- PubMed (publishedVersion)
- Topics
- Physical Sciences › Chemistry › Spectroscopy › Mass Spectrometry Techniques and Applications
- Life Sciences › Immunology and Microbiology › Immunology › Biosimilars and Bioanalytical Methods
- Life Sciences › Biochemistry, Genetics and Molecular Biology › Molecular Biology › Protein purification and stability
- Keywords
- cetuximab, charge heterogeneity, dithiothreitol reduction, deamidation, sample complexity reduction
- MeSH terms
- Cetuximab, Bacterial Proteins, Dithiothreitol, Immunoglobulin Fab Fragments, Isoelectric Focusing, Electrophoresis, Capillary, Spectrometry, Mass, Electrospray Ionization
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.