CoChat

Capillary Isoelectric Focusing-Mass Spectrometry Method for the Separation and Online Characterization of Intact Monoclonal Antibody Charge Variants

Open access
Dai, Jun, Lamp, Jared, Xia, Qiangwei, Zhang, Yingru · 2018 · Analytical Chemistry

The DOI matches its Crossref record; 49 of the 49 references it cites were found in a registry or an index.

Abstract

We report a new online capillary isoelectric focusing-mass spectrometry (CIEF-MS) method for monoclonal antibody (mAb) charge variant analysis using an electrokinetically pumped sheath-flow nanospray ion source and a time-of-flight MS with pressure-assisted chemical mobilization. To develop a successful, reliable CIEF-MS method for mAb, we have selected and optimized many critical, interrelating reagents and parameters that include (1) MS-friendly anolyte and catholyte; (2) a glycerol enhanced sample mixture that reduced non-CIEF electrophoretic mobility and band broadening; (3) ampholyte selected for balancing resolution and MS sensitivity; (4) sheath liquid composition optimized for efficient focusing, mobilization, and electrospray ionization; (5) judiciously selected CIEF running parameters including injection amount, field strength, and applied pressure. The fundamental premise of CIEF was well maintained as verified by the linear correlation (R2 = 0.99) between pI values and migration time using a mixture of pI markers. In addition, the charge variant profiles of trastuzumab, bevacizumab, infliximab, and cetuximab, obtained using this CIEF-MS method, were corroborated by imaged CIEF-UV (iCIEF-UV) analyses. The relative standard deviations (RSD) of absolute migration time of pI markers were all less than 5% (n = 4). Triplicate analyses of bevacizumab showed RSD less than 1% for relative migration time to an internal standard and RSD of 7% for absolute MS peak area. Moreover, the antibody charge variants were characterized using the online intact MS data. To the best of our knowledge, this is the first time that direct online MS detection and characterization were achieved for mAb charge variants resolved by CIEF as indicated by a well-established linear pH gradient and correlated CIEF-UV charge variant profiles.

Overview

Integrity signals

Registry

Crossref · 10.1021/acs.analchem.7b04608

Cites

49 of 49 references verified0 citation errors · 0 not checkable

Statistics

Recomputing p-values needs the paper’s full text.

Verification

Claims the paper makes

We couldn’t retrieve this paper’s full text, so its claims and self-check weren’t run. The registry and citation checks still apply.

Claims other papers make about this one

Each is checked against this paper’s own text: does it say what the citing paper says it does?

Citations

Cites

Show all 49 references

Research works printed but not linked: 1

  1. Michels, 2011, BioProcess Int., 9, 48

Cited by

See all 123

Metadata

Authors
Dai, J., Lamp, J., Xia, Q., & Zhang, Y.
Affiliations
  • Bristol-Myers Squibb (United States) (US)
  • CMP Scientific, Corporation , 760 Parkside Avenue, Suite 211 , , ,
Corresponding author
Dai, Jun
Venue
Analytical Chemistry
Published
2017-12-22
Volume
90
Issue
3
Pages
2246-2254
ISSN
  • 0003-2700 (ISSN-L)
  • 1520-6882
OpenAlex
W2777107256
Cited by
123
References
49
Citations by year
2026: 3 · 2025: 12 · 2024: 13 · 2023: 13 · 2022: 19 · 2021: 24 · 2020: 10 · 2019: 17 · 2018: 12
FWCI
5.26
Type
journal article
Language
en
Open access
Locations
  • Analytical Chemistry (publishedVersion, other-oa)
  • PubMed (publishedVersion)
Funders
Bristol-Myers Squibb
Topics
  • Physical Sciences › Chemistry › Spectroscopy › Mass Spectrometry Techniques and Applications
  • Physical Sciences › Engineering › Biomedical Engineering › Microfluidic and Capillary Electrophoresis Applications
  • Life Sciences › Immunology and Microbiology › Immunology › Biosimilars and Bioanalytical Methods
Keywords
isoelectric focusing, on-line mass spectrometry, trastuzumab, bevacizumab, infliximab, cetuximab, isoelectric point determination
MeSH terms
Antibodies, Monoclonal, Isoelectric Focusing, Reproducibility of Results, Spectrometry, Mass, Electrospray Ionization

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review

How to cite

Cite CoChat for the checks on this page, and the paper for its own findings.

This page
CoChat. (2026). Citation check: Capillary Isoelectric Focusing-Mass Spectrometry Method for the Separation and Online Characterization of Intact Monoclonal Antibody Charge Variants. https://app.cochat.ai/papers/10.1021/acs.analchem.7b04608
The paper
Dai, J., Lamp, J., Xia, Q., & Zhang, Y. (2018). Capillary Isoelectric Focusing-Mass Spectrometry Method for the Separation and Online Characterization of Intact Monoclonal Antibody Charge Variants. Analytical Chemistry. https://doi.org/10.1021/acs.analchem.7b04608

Data sources

Bibliographic data: Semantic Scholar, OpenAlex, Crossref.

Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).

Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.