Student or educator? Sign up with your school email and get 6 months of Pro free.
CoChat
Cited by 343

The DOI matches its Crossref record; 16 of the 16 references it cites were found in a registry or an index.

Dual-Channel Photoelectrochemical Ratiometric Aptasensor with up-Converting Nanocrystals Using Spatial-Resolved Technique on Homemade 3D Printed Device

Qiu, Zhenli, Shu, Jian, Liu, Jingfeng, Tang, Dianping · 2019 · Analytical Chemistry

Abstract

A near-infrared light-activated ratiometric photoelectrochemical aptasensor was fabricated for detection of carcinoembryonic antigen (CEA) coupling with upconversion nanoparticles (UCNPs)-semiconductor nanocrystals-based spatial-resolved technique on a homemade 3D printing device in which a self-regulating integrated electrode was designed for dual signal readout. The as-prepared NaYF 4:Yb,Er UCNPs@CdTe nanocrystals were initially assembled on two adjacent photoelectrodes, then CEA aptamer 1 (A 1 ) and capture DNA (CA) were modified onto two working photoelectrodes (WP 1 and WP 2 ) through covalent binding, respectively, and then gold nanoparticle-labeled CEA aptamer 2 (Au NP-A 2 ) was immobilized on the surface of functional WP 2 for the formation of double-stranded DNA. Upon target CEA introduction, the various concentrations of CEA were captured on the WP 1, whereas the binding of the CEA with Au NP-A 2 could be released from the WP 2 thanks to the highly affinity of CEA toward A 2 . The dual signal readout with the “signal-off” of WP 1 and “signal-on” of WP 2 were employed for the spatial-resolved PEC (SR-PEC) strategy to detect CEA as an analytical model. Combining NaYF 4:Yb,Er UCNPs@CdTe nanocrystals with spatial-resolved model on 3D printing device, the PEC ratiometric aptasensor based on steric hindrance effect and exciton–plasmon interactions (EPI) exhibited a linear range from 10.0 pg mL –1 to 5.0 ng mL –1 with a limit of detection of 4.8 pg mL –1 under 980 nm illumination. The SR-PEC ratiometric strategy showed acceptable stability and reproducibility with a superior anti-interference ability. This approach can provide the guidance for the design of ratiometric, multiplexed, and point-of-care biosensors.

Overview

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Integrity signals

Registry

Crossref · 10.1021/acs.analchem.8b05455

Cites

16 of 16 references verified0 citation errors · 0 not checkable

Statistics

Verification

Claims the paper makes

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Self-check

Percentages, sums and reported differences re-computed from the paper’s own numbers.

The self-check needs the paper’s full text.

Citations

Cites

Show all 16 references

Cited by

Metadata

Authors
Qiu, Z., Shu, J., Liu, J., & Tang, D.
Venue
Analytical Chemistry
Published
2018-12-13
Volume
91
Issue
2
Pages
1260-1268
ISSN
  • 0003-2700 (ISSN-L)
  • 1520-6882
OpenAlex
W2905229296
Cited by
343
References
16
FWCI
11.07
Type
journal article
Language
en
Open access
closed

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review

Data sources

Bibliographic data: Semantic Scholar, OpenAlex, Crossref.

Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).

Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.