The DOI matches its Crossref record; 16 of the 16 references it cites were found in a registry or an index.
Dual-Channel Photoelectrochemical Ratiometric Aptasensor with up-Converting Nanocrystals Using Spatial-Resolved Technique on Homemade 3D Printed Device
Abstract
A near-infrared light-activated ratiometric photoelectrochemical aptasensor was fabricated for detection of carcinoembryonic antigen (CEA) coupling with upconversion nanoparticles (UCNPs)-semiconductor nanocrystals-based spatial-resolved technique on a homemade 3D printing device in which a self-regulating integrated electrode was designed for dual signal readout. The as-prepared NaYF 4:Yb,Er UCNPs@CdTe nanocrystals were initially assembled on two adjacent photoelectrodes, then CEA aptamer 1 (A 1 ) and capture DNA (CA) were modified onto two working photoelectrodes (WP 1 and WP 2 ) through covalent binding, respectively, and then gold nanoparticle-labeled CEA aptamer 2 (Au NP-A 2 ) was immobilized on the surface of functional WP 2 for the formation of double-stranded DNA. Upon target CEA introduction, the various concentrations of CEA were captured on the WP 1, whereas the binding of the CEA with Au NP-A 2 could be released from the WP 2 thanks to the highly affinity of CEA toward A 2 . The dual signal readout with the “signal-off” of WP 1 and “signal-on” of WP 2 were employed for the spatial-resolved PEC (SR-PEC) strategy to detect CEA as an analytical model. Combining NaYF 4:Yb,Er UCNPs@CdTe nanocrystals with spatial-resolved model on 3D printing device, the PEC ratiometric aptasensor based on steric hindrance effect and exciton–plasmon interactions (EPI) exhibited a linear range from 10.0 pg mL –1 to 5.0 ng mL –1 with a limit of detection of 4.8 pg mL –1 under 980 nm illumination. The SR-PEC ratiometric strategy showed acceptable stability and reproducibility with a superior anti-interference ability. This approach can provide the guidance for the design of ratiometric, multiplexed, and point-of-care biosensors.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Photoelectrochemical bioanalysis: the state of the art
Zhao, W.-W., Xu, J.-J., & Chen, H.-Y. (2015) · Chemical Society Reviews · doi:10.1039/c4cs00228h · Cited by 912
Photoelectrochemical DNA Biosensors
Zhao, W.-W., Xu, J.-J., & Chen, H.-Y. (2014) · Chemical Reviews · doi:10.1021/cr500100j · Cited by 857
Lanthanide-Doped Nanocrystals: Synthesis, Optical-Magnetic Properties, and Applications
Wang, G., Peng, Q., & Li, Y. (2011) · Accounts of Chemical Research · doi:10.1021/ar100129p · Cited by 813
THE RADIOIMMUNOASSAY OF CIRCULATING CARCINOEMBRYONIC ANTIGEN OF THE HUMAN DIGESTIVE SYSTEM
Thomson, D. M. P., Krupey, J., Freedman, S. O., & Gold, P. (1969) · Proceedings of the National Academy of Sciences · doi:10.1073/pnas.64.1.161 · Cited by 698
Photostable Ratiometric Pdot Probe for in Vitro and in Vivo Imaging of Hypochlorous Acid
Wu, L., Wu, I.-C., DuFort, C. C., Carlson, M. A., Wu, X., Chen, L., Kuo, C.-T., Qin, Y., Yu, J., Hingorani, S. R., et al. (2017) · Journal of the American Chemical Society · doi:10.1021/jacs.7b01545 · Cited by 349
Shen, J., Zhao, L., & Han, G. (2013) · Advanced Drug Delivery Reviews · doi:10.1016/j.addr.2012.05.007 · Cited by 309
Photoelectrochemical enzymatic biosensors
Zhao, W.-W., Xu, J.-J., & Chen, H.-Y. (2017) · Biosensors and Bioelectronics · doi:10.1016/j.bios.2016.11.009 · Cited by 301
Xu, Z., Quintanilla, M., Vetrone, F., Govorov, A. O., Chaker, M., & Ma, D. (2015) · Advanced Functional Materials · doi:10.1002/adfm.201500810 · Cited by 299
Photoelectrochemical Immunoassays
Zhao, W., Xu, J., & Chen, H. (2017) · Analytical Chemistry · doi:10.1021/acs.analchem.7b04672 · Cited by 298
Degradable Semiconducting Oligomer Amphiphile for Ratiometric Photoacoustic Imaging of Hypochlorite
Yin, C., Zhen, X., Fan, Q., Huang, W., & Pu, K. (2017) · ACS Nano · doi:10.1021/acsnano.7b01092 · Cited by 227
Near-IR Photoresponse in New Up-Converting CdSe/NaYF4:Yb,Er Nanoheterostructures
Yan, C., Dadvand, A., Rosei, F., & Perepichka, D. F. (2010) · Journal of the American Chemical Society · doi:10.1021/ja103743t · Cited by 196
Wang, W., Li, Y., Kang, Z., Wang, F., & Yu, J. C. (2015) · Applied Catalysis B: Environmental · doi:10.1016/j.apcatb.2015.09.022 · Cited by 146
Chai, X., Zhou, X., Zhu, A., Zhang, L., Qin, Y., Shi, G., & Tian, Y. (2013) · Angewandte Chemie International Edition · doi:10.1002/anie.201302958 · Cited by 143
Qiu, Z., Shu, J. H., & Tang, D. (2018) · Analytical Chemistry · doi:10.1021/acs.analchem.8b03446 · Cited by 137
Self-citationLaboria, N., Fragoso, A., Kemmner, W., Latta, D., Nilsson, O., Botero, M. L., Drese, K. S., & O’Sullivan, C. K. (2010) · Analytical Chemistry · doi:10.1021/ac902162e · Cited by 103
Jang, Y., Yanover, D., Čapek, R., Shapiro, A., Grumbach, N., Kauffmann, Y., Sashchiuk, A., & Lifshitz, E. (2016) · The Journal of Physical Chemistry Letters · doi:10.1021/acs.jpclett.6b00995 · Cited by 38
Cited by
Shu, J., & Tang, D. (2020) · Analytical Chemistry · doi:10.1021/acs.analchem.9b04199 · Cited by 976
Self-citationCarbon black as an outstanding and affordable nanomaterial for electrochemical (bio)sensor design
Arduini, F., Cinti, S., Mazzaracchio, V., Scognamiglio, V., Amine, A., & Moscone, D. (2020) · Biosensors and Bioelectronics · doi:10.1016/j.bios.2020.112033 · Cited by 298
CRISPR-Driven Biosensors: A New Frontier in Rapid and Accurate Disease Detection
Razavi, Z., Soltani, M., Souri, M., & Pazoki-Toroudi, H. (2026) · Critical Reviews in Analytical Chemistry · doi:10.1080/10408347.2024.2400267 · Cited by 45
Metadata
- Authors
- Qiu, Z., Shu, J., Liu, J., & Tang, D.
- Venue
- Analytical Chemistry
- Publisher
- American Chemical Society (ACS)
- Published
- 2018-12-13
- Volume
- 91
- Issue
- 2
- Pages
- 1260-1268
- ISSN
- 0003-2700 (ISSN-L)
- 1520-6882
- OpenAlex
- W2905229296
- Cited by
- 343
- References
- 16
- FWCI
- 11.07
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.