The DOI matches its Crossref record.
H2-Based Electrochemical Biosensor with Pd Nanowires@ZIF-67 Molecular Sieve Bilayered Sensing Interface for Immunoassay
Abstract
With the introduction of gas-based contactless electrochemical biosensors lies the prospects of separating the sensing interface from the bioassembly platform, enhancing stability, and exploring signal transduction mechanism, all intimately linking to development of immunoassay. Herein, we report on a H 2 -based electrochemical biosensor whose signals derived from the chemical signal transduction between a H 2 and Pd nanowires@ZIF-67 (ZIF: Zeolitic Imidazolate Frameworks) bilayered sensing interface for immunoassay. Dendritic Pt nanoparticles (DPNs) conjugated on the detection antibody were introduced on the interface of a magnetic microsphere according to an immune sandwich assembly between the antigen and antibody. H 2 as a bridge originates from DPNs catalyzing NH 3 BH 3 and links biological signals to electrical signals by reacting with Pd nanowires. Nevertheless, the response of Pd nanowires being extremely effected by O 2 in air due to the competitive adsorption on the surface of Pd nanostructures as well as the reaction between chemisorbed O (Pd–O) and adsorbed dihydrogen lead to a decrease in H absorption into PdH x and poor sensing responses under low target concentration. Porous ZIF-67 (window aperture 0.331 nm) as a molecular sieve self-assembling on the surface of the Pd nanowires film could easily permeate H 2 (kinetic diameter of 0.289 nm), while interferential O 2 (kinetic diameter of 0.346 nm) has difficultly passing through the ZIF-67 layer to contact Pd nanowires and achieves a response of a lower concentration target as well as faster response rate. Under optimal conditions, H 2 -based electrochemical biosensors exhibit great response toward target alpha-fetoprotein (AFP) within a dynamic working range of 0.1–50 ng mL –1 at a detection limit of 0.04 ng mL –1 . Our strategy provides a reusable sensing interface, high specificity, and acceptable accuracy for the immunoassay. In addition, it also expands a promising platform for application as a molecular sieve in electrochemical biosensors.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cited by
Electrochemical Impedance Spectroscopy (EIS): Principles, Construction, and Biosensing Applications
Magar, H. S., Hassan, R. Y. A., & Mulchandani, A. (2021) · Sensors · doi:10.3390/s21196578 · Cited by 1,335
Wearable and flexible electrochemical sensors for sweat analysis: a review
Gao, F., Liu, C., Zhang, L., Liu, T., Wang, Z., Song, Z., Cai, H., Fang, Z., Chen, J., Wang, J., et al. (2023) · Microsystems & Nanoengineering · doi:10.1038/s41378-022-00443-6 · Cited by 764
Recent advances in isolation and detection of exosomal microRNAs related to Alzheimer's disease
Pishbin, E., Sadri, F., Dehghan, A., Kiani, M. J., Hashemi, N., Zare, I., Mousavi, P., & Rahi, A. (2023) · Environmental Research · doi:10.1016/j.envres.2023.115705 · Cited by 25
Metadata
- Authors
- Lv, S., Zhang, K., Zhu, L., Tang, D., Niessner, R., & Knopp, D.
- Venue
- Analytical Chemistry
- Publisher
- American Chemical Society (ACS)
- Published
- 2019-08-22
- Volume
- 91
- Issue
- 18
- Pages
- 12055-12062
- ISSN
- 0003-2700 (ISSN-L)
- 1520-6882
- OpenAlex
- W2969948464
- Cited by
- 240
- References
- 0
- FWCI
- 7.31
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.