The DOI matches its Crossref record; 3 of the 3 references it cites were found in a registry or an index.
pH Impacts the Orientation of Antibody Adsorbed onto Gold Nanoparticles
Abstract
Novel detection strategies that exploit the unique properties of gold nanoparticles (AuNPs) hold great promise for the advancement of diagnostic testing. Fundamental to many of these nanoparticle-enabled techniques is the immobilization of antibodies onto the AuNP surface to afford selective binding to target species. Orientation and loading density of the immobilized antibodies govern F ab accessibility and are critical to the analytical performance. Here, we use pH to systematically control the surface charge distribution on an antibody and investigate the impact of protein charge on adsorption to AuNPs. Nanoparticle tracking analysis (NTA) is used to measure the adsorption dynamics of anti-horseradish peroxidase antibody (anti-HRP) onto AuNPs at different pHs. NTA enables in situ measurement of antibody adsorption on AuNP by measuring the increase in hydrodynamic diameter ( D H ) of the AuNPs as a function of antibody concentration. The adsorption affinity, protein layer thickness, and binding cooperativity at each pH are extracted from the best fit of the adsorption isotherms to the Hill-modified Langmuir equation. Our data show a monolayer of antibody is formed at saturation at pHs 7.5, 8.0, and 8.5, and no difference in anti-HRP-AuNP binding constants is observed in this pH range ( K d ∼11 nM). However, the increase in D H of the AuNPs with adsorbed protein at monolayer coverage is pH-dependent, measuring 13.2 ± 1.1 nm, 9.8 ± 1.0 nm, and 7.4 ± 0.6 nm for pHs 7.5, 8.0, and 8.5, respectively. Moreover, results of an enzyme-mediated assay reveal the antigen-binding capacity of the immobilized anti-HRP antibody is 33 ± 2%, 23 ± 7%, and 18 ± 2% when adsorbed at pHs 7.5, 8.0, and 8.5, respectively. Our data confirm that antibody charge can be altered with pH to modulate and optimize antibody orientation on AuNP. These studies describe our continued efforts to establish design criteria to prepare conjugates with maximum antigen-binding activity that will enhance the performance of biofunctional nanomaterials.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Time Evolution of the Nanoparticle Protein Corona
Casals, E., Pfaller, T., Duschl, A., Oostingh, G. J., & Puntes, V. (2010) · ACS Nano · doi:10.1021/nn901372t · Cited by 1,211
A Decade of the Protein Corona
Ke, P. C., Lin, S., Parak, W. J., Davis, T. P., & Caruso, F. (2017) · ACS Nano · doi:10.1021/acsnano.7b08008 · Cited by 672
Treuel, L., Brandholt, S., Maffre, P., Wiegele, S., Shang, L., & Nienhaus, G. U. (2014) · ACS Nano · doi:10.1021/nn405019v · Cited by 419
Cited by
Environmental dimensions of the protein corona
Wheeler, K. E., Chetwynd, A. J., Fahy, K. M., Hong, B. S., Tochihuitl, J. A., Foster, L. A., & Lynch, I. (2021) · Nature Nanotechnology · doi:10.1038/s41565-021-00924-1 · Cited by 400
Nanoparticle protein corona: from structure and function to therapeutic targeting
Bashiri, G., Padilla, M. S., Swingle, K. L., Shepherd, S. J., Mitchell, M. J., & Wang, K. (2023) · Lab on a Chip · doi:10.1039/d2lc00799a · Cited by 296
Zhang, L., Mazouzi, Y., Salmain, M., Liedberg, B., & Boujday, S. (2020) · Biosensors and Bioelectronics · doi:10.1016/j.bios.2020.112370 · Cited by 258
Oriented immobilization of antibodies onto sensing platforms - A critical review
Gao, S., Guisán, J. M., & Rocha-Martin, J. (2022) · Analytica Chimica Acta · doi:10.1016/j.aca.2021.338907 · Cited by 257
Metadata
- Authors
- Ruiz, G., Tripathi, K., Okyem, S., & Driskell, J. D.
- Venue
- Bioconjugate Chemistry
- Publisher
- American Chemical Society (ACS)
- Published
- 2019-03-07
- Volume
- 30
- Issue
- 4
- Pages
- 1182-1191
- ISSN
- 1043-1802 (ISSN-L)
- 1520-4812
- OpenAlex
- W2922485383
- Cited by
- 192
- References
- 3
- FWCI
- 5.11
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.