The DOI matches its Crossref record; 13 of the 13 references it cites were found in a registry or an index.
High Performance Humidity Fluctuation Sensor for Wearable Devices via a Bioinspired Atomic-Precise Tunable Graphene-Polymer Heterogeneous Sensing Junction
Abstract
Measurements of an individual’s water metabolism dynamical information can provide us rich biological information in a noninvasive way. This concept is hindered by the trade-off between the sensitivity and responsive velocity of traditional moisture sensors. Herein, inspired by the molecular detecting system based on weak bond interactions in natural organisms, we designed a new concept of a tunable graphene-polymer heterogeneous nanosensing junction by confining a reasonable thickness sensing material into graphene nanochannels. The fundamentally new sensing mechanism based on dynamical hydrogen bonds endows the sensor with over 4 orders of magnitude sensitivity toward a wide range of relative humidity (RH) (from 0% to 97%) with unprecedented fast response (20 ms) and recovery times (17 ms) with little humidity hysteresis. The promising advantages of the sensor allow us to record humidity fluctuation information in real time during a user’s speech and breath, which can both reveal the speech feature and monitor the respiration rate accurately. Importantly, this advanced sensor provides a new opportunity for accurate and reliable physiological and psychological monitoring by detecting the subtlest RH fluctuations on human skin in a noncontact way.
Overview
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Mussel-inspired surface chemistry for multifunctional coatings
Lee, H., Dellatore, S. M., Miller, W. M., & Messersmith, P. B. (2007) · Science · doi:10.1126/science.1147241 · Cited by 10,965
Spontaneous fluctuations in brain activity observed with functional magnetic resonance imaging
Fox, M. D., & Raichle, M. E. (2007) · Nature Reviews Neuroscience · doi:10.1038/nrn2201 · Cited by 6,700
Fully integrated wearable sensor arrays for multiplexed in situ perspiration analysis
Gao, W., Emaminejad, S., Nyein, H. Y. Y., Challa, S., Chen, K., Peck, A., Fahad, H. M., Ota, H., Shiraki, H., Kiriya, D., et al. (2016) · Nature · doi:10.1038/nature16521 · Cited by 5,087
Liu, Y., Ai, K., & Lu, L. (2014) · Chemical Reviews · doi:10.1021/cr400407a · Cited by 4,794
Hammock, M. L., Chortos, A., Tee, B. C. ‐., Tok, J. B. ‐., & Bao, Z. (2013) · Advanced Materials · doi:10.1002/adma.201302240 · Cited by 2,396
A wearable and highly sensitive pressure sensor with ultrathin gold nanowires
Gong, S., Schwalb, W., Wang, Y., Chen, Y., Tang, Y., Si, J., Shirinzadeh, B., & Cheng, W. (2014) · Nature Communications · doi:10.1038/ncomms4132 · Cited by 2,064
Self-citationNanowire active-matrix circuitry for low-voltage macroscale artificial skin
Takei, K., Takahashi, T., Ho, J. C., Ko, H., Gillies, A. G., Leu, P. W., Fearing, R. S., & Javey, A. (2010) · Nature Materials · doi:10.1038/nmat2835 · Cited by 1,274
Soft Microfluidic Assemblies of Sensors, Circuits, and Radios for the Skin
Xu, S., Zhang, Y., Jia, L., Mathewson, K. E., Jang, K.-I., Kim, J., Fu, H., Huang, X., Chava, P., Wang, R., et al. (2014) · Science · doi:10.1126/science.1250169 · Cited by 1,199
User-interactive electronic skin for instantaneous pressure visualization
Wang, C., Hwang, D., Yu, Z., Takei, K., Park, J., Chen, T., Ma, B., & Javey, A. (2013) · Nature Materials · doi:10.1038/nmat3711 · Cited by 1,182
Self-citationThe cost of cortical computation.
Lennie, P. (2003) · Current Biology · doi:10.1016/s0960-9822(03)00135-0 · Cited by 1,134
Cited by
The Importance of Respiratory Rate Monitoring: From Healthcare to Sport and Exercise
Nicolò, A., Massaroni, C., Schena, E., & Sacchetti, M. (2020) · Sensors · doi:10.3390/s20216396 · Cited by 440
Materials, Actuators, and Sensors for Soft Bioinspired Robots
Ilami, M., Bagheri, H., Ahmed, R., Skowronek, E. O., & Marvi, H. (2021) · Advanced Materials · doi:10.1002/adma.202003139 · Cited by 435
Evolution of breath analysis based on humidity and gas sensors: Potential and challenges
Tai, H., Wang, S., Duan, Z., & Jiang, Y. (2020) · Sensors and Actuators B: Chemical · doi:10.1016/j.snb.2020.128104 · Cited by 412
Flexible Noncontact Sensing for Human–Machine Interaction
Lu, L., Jiang, C., Hu, G., Liu, J., & Yang, B. (2021) · Advanced Materials · doi:10.1002/adma.202100218 · Cited by 386
Recent advances in humidity sensors for human body related humidity detection
Duan, Z., Jiang, Y., & Tai, H. (2021) · Journal of Materials Chemistry C · doi:10.1039/d1tc04180k · Cited by 365
Metadata
- Authors
- He, J., Xiao, P., Shi, J., Liang, Y., Lu, W., Chen, Y., Wang, W., Théato, P., Kuo, S.-W., & Chen, T.
- Venue
- Chemistry of Materials
- Publisher
- American Chemical Society (ACS)
- Published
- 2018-06-11
- Volume
- 30
- Issue
- 13
- Pages
- 4343-4354
- ISSN
- 0897-4756 (ISSN-L)
- 1520-5002
- OpenAlex
- W2808608227
- Cited by
- 164
- References
- 13
- FWCI
- 6.30
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: High Performance Humidity Fluctuation Sensor for Wearable Devices via a Bioinspired Atomic-Precise Tunable Graphene-Polymer Heterogeneous Sensing Junction. https://app.cochat.ai/papers/10.1021/acs.chemmater.8b01587
- The paper
- He, J., Xiao, P., Shi, J., Liang, Y., Lu, W., Chen, Y., Wang, W., Théato, P., Kuo, S.-W., & Chen, T. (2018). High Performance Humidity Fluctuation Sensor for Wearable Devices via a Bioinspired Atomic-Precise Tunable Graphene-Polymer Heterogeneous Sensing Junction. Chemistry of Materials. https://doi.org/10.1021/acs.chemmater.8b01587
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.