The DOI matches its Crossref record; 450 of the 450 references it cites were found in a registry or an index.
Chemistry of MRI Contrast Agents: Current Challenges and New Frontiers
Open accessAbstract
Tens of millions of contrast-enhanced magnetic resonance imaging (MRI) exams are performed annually around the world. The contrast agents, which improve diagnostic accuracy, are almost exclusively small, hydrophilic gadolinium(III) based chelates. In recent years concerns have arisen surrounding the long-term safety of these compounds, and this has spurred research into alternatives. There has also been a push to develop new molecularly targeted contrast agents or agents that can sense pathological changes in the local environment. This comprehensive review describes the state of the art of clinically approved contrast agents, their mechanism of action, and factors influencing their safety. From there we describe different mechanisms of generating MR image contrast such as relaxation, chemical exchange saturation transfer, and direct detection and the types of molecules that are effective for these purposes. Next we describe efforts to make safer contrast agents either by increasing relaxivity, increasing resistance to metal ion release, or by moving to gadolinium(III)-free alternatives. Finally we survey approaches to make contrast agents more specific for pathology either by direct biochemical targeting or by the design of responsive or activatable contrast agents.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Items 201–400 of 450
Dual‐Function Probe to Detect Protease Activity for Fluorescence Measurement and 19F MRI
Mizukami, S., Takikawa, R., Sugihara, F., Shirakawa, M., & Kikuchi, K. (2009) · Angewandte Chemie International Edition · doi:10.1002/anie.200806328 · Cited by 142
Callera, F., & de Melo, C. M. T. P. (2007) · Stem Cells and Development · doi:10.1089/scd.2007.0083 · Cited by 139
Folate Receptor Targeted Bimodal Liposomes for Tumor Magnetic Resonance Imaging
Kamaly, N., Kalber, T. L., Thanou, M., Bell, J. D., & Miller, A. D. (2009) · Bioconjugate Chemistry · doi:10.1021/bc8002259 · Cited by 139
Bogdanov, A. A., Jr., Matuszewski, L., Bremer, C., et al. (2002) · Molecular Imaging · doi:10.1162/153535002753395671 · Cited by 139
Kellar, K. E., Fujii, D. K., Gunther, W. H. H., Briley-S�b�, K., Bj�rnerud, A., Spiller, M., & Koenig, S. H. (2000) · Journal of Magnetic Resonance Imaging · Cited by 138
Peroxidase Substrate Nanosensors for MR Imaging
Pérez, J. M. S., Simeone, F. J., Tsourkas, A., Josephson, L., & Weissleder, R. (2003) · Nano Letters · doi:10.1021/nl034983k · Cited by 135
A Modular System for the Synthesis of Multiplexed Magnetic Resonance Probes
Mastarone, D. J., Harrison, V. S. R., Eckermann, A. L., Parigi, G., Luchinat, C., & Meade, T. J. (2011) · Journal of the American Chemical Society · doi:10.1021/ja1099616 · Cited by 134
CEST and PARACEST MR contrast agents
Hancu, I., Dixon, W. T., Woods, M., Vinogradov, E., Sherry, A. D., & Lenkinski, R. E. (2010) · Acta Radiologica · doi:10.3109/02841851.2010.502126 · Cited by 134
Diagnosis of Nephrogenic Systemic Fibrosis by means of Elemental Bioimaging and Speciation Analysis
Birka, M., Wentker, K. S., Lusmöller, E., Arheilger, B., Wehe, C. A., Sperling, M., Stadler, R., & Kärst, U. (2015) · Analytical Chemistry · doi:10.1021/ac504488k · Cited by 132
Annexin A5-Functionalized Bimodal Lipid-Based Contrast Agents for the Detection of Apoptosis
van Tilborg, G. A. F., Mulder, W. J. M., Deckers, N. M., Storm, G., Reutelingsperger, C. P. M., Strijkers, G. J., & Nicolay, K. (2006) · Bioconjugate Chemistry · doi:10.1021/bc0600259 · Cited by 132
Heesakkers, R. A. M., Jager, G. J., Hövels, A. M., de Hoop, B., van den Bosch, H. C. M., Raat, F., Witjes, J. A., Mulders, P., van der Kaa, C. H., & Barentsz, J. O. (2009) · Radiology · doi:10.1148/radiol.2512071018 · Cited by 132
Inflammatory Response After Ischemic Stroke
Nighoghossian, N., Wiart, M., Cakmak, S., Berthezène, Y., Derex, L., Cho, T., Nemoz, C., Chapuis, F. R., Tisserand, G. L., Pialat, J., et al. (2006) · Stroke · doi:10.1161/01.str.0000254548.30258.f2 · Cited by 130
A Redox‐Activated MRI Contrast Agent that Switches Between Paramagnetic and Diamagnetic States
Tsitovich, P. B., Spernyak, J. A., & Morrow, J. R. (2013) · Angewandte Chemie International Edition · doi:10.1002/anie.201306394 · Cited by 128
Saleh, A., Schroeter, M., Ringelstein, A., Hartung, H., Siebler, M., Mödder, U., & Jander, S. (2007) · Stroke · doi:10.1161/strokeaha.107.481788 · Cited by 127
Specific E-selectin targeting with a superparamagnetic MRI contrast agent
Boutry, S., Laurent, S., Elst, L. V., & Müller, R. N. (2006) · Contrast Media & Molecular Imaging · doi:10.1002/cmmi.87 · Cited by 125
Serebriiskii, I. G., & Golemis, E. A. (2000) · Analytical Biochemistry · doi:10.1006/abio.2000.4672 · Cited by 123
Iopamidol: Exploring the potential use of a well‐established x‐ray contrast agent for MRI
Aime, S., Calabi, L., Biondi, L., Miranda, M. D., Ghelli, S., Paleari, L., Rebaudengo, C., & Terreno, E. (2005) · Magnetic Resonance in Medicine · doi:10.1002/mrm.20441 · Cited by 123
Gianolio, E., Bardini, P., Arena, F., Stefanìa, R., Gregorio, E. D., Iani, R., & Aime, S. (2017) · Radiology · doi:10.1148/radiol.2017162857 · Cited by 123
Rudovský, J., Cígler, P., Kotek, J., Hermann, P., Vojtišek, P., Lukeš, I., Peters, J. A., Elst, L. V., & Müller, R. N. (2005) · Chemistry - A European Journal · doi:10.1002/chem.200400367 · Cited by 121
Molecular imaging of tumors and metastases using chemical exchange saturation transfer (CEST) MRI
Rivlin, M., Horev, J., Tsarfaty, I., & Navon, G. (2013) · Scientific Reports · doi:10.1038/srep03045 · Cited by 120
Synthesis and Relaxometric Studies of a Dendrimer‐Based pH‐Responsive MRI Contrast Agent
Ali, M. M., Woods, M., Caravan, P. D., Opina, A. C. L., Spiller, M., Fettinger, J. C., & Sherry, A. D. (2008) · Chemistry - A European Journal · doi:10.1002/chem.200800402 · Cited by 120
Self-citationLiu, G., Li, Y., & Pagel, M. D. (2007) · Magnetic Resonance in Medicine · doi:10.1002/mrm.21428 · Cited by 119
Metabolism and pharmacokinetics of MnDPDP in man
Toft, K. G., Hustvedt, S. O., Grant, D., Martinsen, I., Gordon, P. B., Friisk, G. A., Korsmo, Å., & Skotland, T. (1997) · Acta Radiologica · doi:10.1080/02841859709172400 · Cited by 119
Development of a Tumor-Targeting MR Contrast Agent Using the High-Affinity Folate Receptor
Konda, S. D., Aref, M., Brechbiel, M. W., & Wiener, E. C. (2000) · Investigative Radiology · doi:10.1097/00004424-200001000-00006 · Cited by 119
van Tilborg, G. A. F., Vucic, E., Strijkers, G. J., Cormode, D. P., Mani, V., Skajaa, T., Reutelingsperger, C. P. M., Fayad, Z. A., Mulder, W. J. M., & Nicolay, K. (2010) · Bioconjugate Chemistry · doi:10.1021/bc100091q · Cited by 118
Unterweger, H., Janko, C., Schwarz, M. A., Dézsi, L., Urbanics, R., Matuszak, J., Őrfi, E., Fülöp, T., Bäuerle, T., Szebeni, J., et al. (2017) · International Journal of Nanomedicine · doi:10.2147/ijn.s138108 · Cited by 117
Rodrı́guez, E., Nilges, M. J., Weissleder, R., & Chen, J. W. (2009) · Journal of the American Chemical Society · doi:10.1021/ja905274f · Cited by 116
Terreno, E., Castelli, D. D., Cravotto, G., Milone, L., & Aime, S. (2004) · Investigative Radiology · doi:10.1097/01.rli.0000116607.26372.d0 · Cited by 116
Magnetic resonance imaging of pancreatic islets transplanted into the liver in humans
Saudek, F., Jirák, D., Girman, P., Herynek, V., Dezortová, M., Kříž, J., Peregrin, J., Berková, Z., Zacharovová, K., & Hájek, M. (2010) · Transplantation · doi:10.1097/tp.0b013e3181ffba5e · Cited by 115
Bernd, H., De Kerviler, E., Gaillard, S., & Bonnemain, B. (2009) · Investigative Radiology · doi:10.1097/rli.0b013e3181a0068b · Cited by 115
Molecular Magnetic Resonance Imaging of Pulmonary Fibrosis in Mice
Caravan, P. D., Yang, Y., Zachariah, R., Schmitt, A. D., Mino-Kenudson, M. A., Chen, H. H., Sosnovik, D. E., Dai, G., Fuchs, B. C., & Lanuti, M. D. (2013) · American Journal of Respiratory Cell and Molecular Biology · doi:10.1165/rcmb.2013-0039oc · Cited by 115
Self-citationWadghiri, Y. Z., Li, J., Wang, J., Hoang, D. M., Sun, Y., Xu, H., Tsui, W., Li, Y., Boutajangout, A., Wang, A., et al. (2013) · PLoS ONE · doi:10.1371/journal.pone.0057097 · Cited by 114
Sillerud, L. O., Solberg, N. O., Chamberlain, R., Orlando, R. A., Heidrich, J. E., Brown, D. C., Brady, C. I., Jagt, T. A. V., Garwood, M., & Jagt, D. L. V. (2013) · Journal of Alzheimer s Disease · doi:10.3233/jad-121171 · Cited by 114
Chalmers, K., Luca, E. D., Hogg, N. H. M., Kenwright, A. M., Kuprov, I., Parker, D., Botta, M., Wilson, J. I., & Blamire, A. M. (2009) · Chemistry - A European Journal · doi:10.1002/chem.200902300 · Cited by 114
Multilocus Binding Increases the Relaxivity of Protein‐Bound MRI Contrast Agents
Zhang, Z., Greenfield, M. T., Spiller, M., McMurry, T. J., Lauffer, R. B., & Caravan, P. D. (2005) · Angewandte Chemie International Edition · doi:10.1002/anie.200502245 · Cited by 114
Self-citationIn vivo maps of extracellular pH in murine melanoma by CEST–MRI
Castelli, D. D., Ferrauto, G., Cutrìn, J. C., Terreno, E., & Aime, S. (2013) · Magnetic Resonance in Medicine · doi:10.1002/mrm.24664 · Cited by 113
Gale, E. M., Zhu, J., & Caravan, P. D. (2013) · Journal of the American Chemical Society · doi:10.1021/ja4094132 · Cited by 113
Self-citationMultimodal Magnetic‐Resonance/Optical‐Imaging Contrast Agent Sensitive to NADH
Tu, C., Nagao, R. J., & Louie, A. Y. (2009) · Angewandte Chemie International Edition · doi:10.1002/anie.200900984 · Cited by 112
Rose, H. M., Witte, C., Rossella, F., Klippel, S., Freund, C., & Schröder, L. (2014) · Proceedings of the National Academy of Sciences · doi:10.1073/pnas.1406797111 · Cited by 112
Measuring in vivo tumor pHe with CEST‐FISP MRI
Sheth, V. R., Li, Y., Chen, L. Q., Howison, C. M., Flask, C. A., & Pagel, M. D. (2011) · Magnetic Resonance in Medicine · doi:10.1002/mrm.23038 · Cited by 112
Gao, G., Im, G. H., Kim, M.-S., Lee, W. J., Yang, J., Jeon, H., Lee, J. H., & Lee, D. S. (2010) · Small · doi:10.1002/smll.200902317 · Cited by 110
Yancy, A. D., Olzinski, A. R., Hu, T. C., Lenhard, S. C., Aravindhan, K., Gruver, S., Jacobs, P. M., Willette, R. N., & Jucker, B. M. (2005) · Journal of Magnetic Resonance Imaging · doi:10.1002/jmri.20283 · Cited by 107
Goyen, M., Edelman, M., Perreault, P., O'Riordan, E., Bertoni, H., Taylor, J., Siragusa, D. A., Sharafuddin, M. J., Mohler, E. R., Breger, R. K., et al. (2005) · Radiology · doi:10.1148/radiol.2363040577 · Cited by 106
Dual-modality gene reporter for in vivo imaging
Patrick, P. S., Hammersley, J., Loizou, L., Kettunen, M. I., Rodrigues, T. B., Hu, D., Tee, S. S., Hesketh, R., Lyons, S. K., Soloviev, D., et al. (2013) · Proceedings of the National Academy of Sciences · doi:10.1073/pnas.1319000111 · Cited by 105
High Relaxivity Magnetic Resonance Imaging Contrast Agents Part 1
Dumas, S., Jacques, V., Sun, W., Troughton, J. S., Welch, J., Chasse, J. M., Schmitt‐Willich, H., & Caravan, P. D. (2010) · Investigative Radiology · doi:10.1097/rli.0b013e3181ee5a9e · Cited by 104
Self-citationSchmitt‐Willich, H., Brehm, M., Ewers, C. L. J., Michl, G., Müller‐Fahrnow, A., Petrov, O., Platzek, J., Radüchel, B., & Sülzle, D. (1999) · Inorganic Chemistry · doi:10.1021/ic981072i · Cited by 103
Dendritic PARACEST contrast agents for magnetic resonance imaging
Pikkemaat, J. A., Wegh, R. T., Lamerichs, R. M. J. N., van de Molengraaf, R. A., Langereis, S., Burdinski, D., Raymond, A. Y. F., Janssen, H. M., de Waal, B. F. M., Willard, N. P., et al. (2007) · Contrast Media & Molecular Imaging · doi:10.1002/cmmi.149 · Cited by 103
Boehm‐Sturm, P., Haeckel, A., Hauptmann, R., Mueller, S. G., Kuhl, C. K., & Schellenberger, E. A. (2017) · Radiology · doi:10.1148/radiol.2017170116 · Cited by 103
Li, A. X., Wojciechowski, F., Suchý, M., Jones, C. K., Hudson, R. H. E., Menon, R. S., & Bartha, R. (2008) · Magnetic Resonance in Medicine · doi:10.1002/mrm.21482 · Cited by 102
Anzai, Y., & Prince, M. R. (1997) · Journal of Magnetic Resonance Imaging · doi:10.1002/jmri.1880070111 · Cited by 102
Currently used non-specific extracellular MR contrast media
Bellin, M., Vasile, M., & Precetti-Morel, S. (2003) · European Radiology · doi:10.1007/s00330-003-1912-x · Cited by 102
Demyelinating Diseases: Myeloperoxidase as an Imaging Biomarker and Therapeutic Target
Forghani, R., Wojtkiewicz, G. R., Zhang, Y., Seeburg, D. P., Bautz, B. R. M., Pulli, B., Milewski, A., Atkinson, W. L., Iwamoto, Y., Zhang, E. R., et al. (2012) · Radiology · doi:10.1148/radiol.12111593 · Cited by 102
Jordan, M. V. C., Lo, S., Chen, S., Preihs, C., Chirayil, S., Zhang, S., Kapur, P., Li, W.-H., Rodriguez, L. M. D. L., Lubag, A. J. M., et al. (2016) · Proceedings of the National Academy of Sciences · doi:10.1073/pnas.1609450113 · Cited by 102
Gadolinium‐based contrast agents and NSF: Evidence from animal experience
Sieber, M. A., Steger‐Hartmann, T., Lengsfeld, P., & Pietsch, H. (2009) · Journal of Magnetic Resonance Imaging · doi:10.1002/jmri.21971 · Cited by 101
Ye, F., Jeong, E., Jia, Z., Yang, T., Parker, D., & Lu, Z. (2008) · Bioconjugate Chemistry · doi:10.1021/bc800211r · Cited by 100
Dees, A., Zahl, A., Puchta, R., Hommes, N. J. R. V. E., Heinemann, F. W., & Ivanović‐Burmazović, I. (2007) · Inorganic Chemistry · doi:10.1021/ic061852o · Cited by 100
Vojtišek, P., Cígler, P., Kotek, J., Rudovský, J., Hermann, P., & Lukeš, I. (2005) · Inorganic Chemistry · doi:10.1021/ic048190s · Cited by 99
Konda, S. D., WANG, S., Brechbiel, M. W., & Wiener, E. C. (2002) · Investigative Radiology · doi:10.1097/00004424-200204000-00005 · Cited by 98
Wedeking, P. W., Sotak, C. H., Telser, J., Kumar, K., Chang, C. A., & Tweedle, M. F. (1992) · Magnetic Resonance Imaging · doi:10.1016/0730-725x(92)90378-d · Cited by 97
Liu, G., Li, Y., Sheth, V. R., & Pagel, M. D. (2012) · Molecular Imaging · doi:10.2310/7290.2011.00026 · Cited by 96
Temme, S., Grapentin, C., Quast, C., Jacoby, C., Grandoch, M., Ding, Z., Owenier, C., Mayenfels, F., Fischer, J. W., Schubert, R., et al. (2015) · Circulation · doi:10.1161/circulationaha.114.010962 · Cited by 95
Liu, G., Liang, Y., Bar‐Shir, A., Chan, K. W. Y., Galpoththawela, C., Bernard, S. M., Tse, T., Yadav, N. N., Walczak, P., McMahon, M. T., et al. (2011) · Journal of the American Chemical Society · doi:10.1021/ja204701x · Cited by 94
Redox‐ and Hypoxia‐Responsive MRI Contrast Agents
Do, Q. N., Ratnakar, J., Kovács, Z. Z., & Sherry, A. D. (2014) · ChemMedChem · doi:10.1002/cmdc.201402034 · Cited by 94
Glycoconjugates of gadolinium complexes for MRI applications
Fulton, D. A., Elemento, E. M., Aime, S., Chaabane, L., Botta, M., & Parker, D. (2006) · Chemical Communications · doi:10.1039/b517997a · Cited by 94
Huang, C., & Tsourkas, A. (2013) · Current Topics in Medicinal Chemistry · doi:10.2174/1568026611313040002 · Cited by 94
T1ρ-weighted Dynamic Glucose-enhanced MR Imaging in the Human Brain
Paech, D., Schuenke, P., Koehler, C., Windschuh, J., Mundiyanapurath, S., Bickelhaupt, S., Bonekamp, D., Bäumer, P., Bachert, P., Ladd, M. E., et al. (2017) · Radiology · doi:10.1148/radiol.2017162351 · Cited by 93
Purysko, A. S., Remer, E. M., Coppa, C. P., Obuchowski, N. A., Schneider, E., & Veniero, J. C. (2011) · American Journal of Roentgenology · doi:10.2214/ajr.11.6836 · Cited by 92
Long, C. M., van Laarhoven, H. W. M., Bulte, J. W. M., & Levitsky, H. I. (2009) · Cancer Research · doi:10.1158/0008-5472.can-08-3691 · Cited by 92
MR contrast material for vascular enhancement: value of superparamagnetic iron oxide.
Mayo-Smith, W. W., Saini, S., Slater, G. J., Kaufman, J. A., Sharma, P., & Hahn, P. F. (1996) · American Journal of Roentgenology · doi:10.2214/ajr.166.1.8571910 · Cited by 91
Gale, E. M., Mukherjee, S., Liu, C., Loving, G. S., & Caravan, P. D. (2014) · Inorganic Chemistry · doi:10.1021/ic502005u · Cited by 90
Self-citationIn Vivo Imaging with a Cell-Permeable Porphyrin-Based MRI Contrast Agent
Lee, T., Zhang, X., Dhar, S., Faas, H., Lippard, S. J., & Jasanoff, A. (2010) · Chemistry & Biology · doi:10.1016/j.chembiol.2010.05.009 · Cited by 89
A Highly Stable Gadolinium Complex with a Fast, Associative Mechanism of Water Exchange
Thompson, M. K., Botta, M., Nicolle, G. M., Helm, L., Aime, S., Merbach, A. E., & Raymond, K. N. (2003) · Journal of the American Chemical Society · doi:10.1021/ja037441d · Cited by 89
Dunand, F. A., Dickins, R. S., Parker, D., & Merbach, A. E. (2001) · Chemistry - A European Journal · doi:10.1002/1521-3765(20011203)7:23<5160::aid-chem5160>3.0.co;2-2 · Cited by 88
Barnett, B. P., Ruı́z-Cabello, J., Hota, P. V., Ouwerkerk, R., Shamblott, M. J., Lauzon, C., Walczak, P., Gilson, W. D., Chacko, V. P., Kraitchman, D. L., et al. (2011) · Contrast Media & Molecular Imaging · doi:10.1002/cmmi.424 · Cited by 88
Xue, S., Yang, H., Qiao, J., Pu, F., Jiang, J., Hubbard, K., Hekmatyar, K., Langley, J. A., Salarian, M., Long, R. C., et al. (2015) · Proceedings of the National Academy of Sciences · doi:10.1073/pnas.1423021112 · Cited by 87
Nuclear and Electronic Relaxation of Eu2+(aq): An Extremely Labile Aqua Ion1
Caravan, P. D., Tóth, É., Rockenbauer, A., & Merbach, A. E. (1999) · Journal of the American Chemical Society · doi:10.1021/ja992264v · Cited by 87
Self-citationYoo, B., Raam, M. S., Rosenblum, R., et al. (2007) · Contrast Media & Molecular Imaging · doi:10.1002/cmmi.145 · Cited by 87
Tsitovich, P. B., Cox, J. M., Benedict, J. B., & Morrow, J. R. (2015) · Inorganic Chemistry · doi:10.1021/acs.inorgchem.5b02144 · Cited by 87
Liver Imaging With Ferumoxides (Feridex??)
Clémеnt, O., Siauve, N., nod, C.-A. C., & Frija, G. G. (1998) · Topics in Magnetic Resonance Imaging · doi:10.1097/00002142-199806000-00003 · Cited by 87
Gadofosveset-enhanced magnetic resonance angiography
Goyen, M. (2008) · Vascular Health and Risk Management · doi:10.2147/vhrm.2008.04.01.1 · Cited by 86
Poduslo, J. F., & Curran, G. L. (1996) · Journal of Neurochemistry · doi:10.1046/j.1471-4159.1996.66041599.x · Cited by 86
Eldredge-Hindy, H., Spiller, M., Chasse, J. M., et al. (2006) · Investigative Radiology · doi:10.1097/01.rli.0000199293.86956.48 · Cited by 85
Ratnakar, S. J., Woods, M., Lubag, A. J. M., Kovács, Z., & Sherry, A. D. (2007) · Journal of the American Chemical Society · doi:10.1021/ja076325y · Cited by 85
Chelating Tendencies of N,N'-Ethylenebis-[2-(o-hydroxyphenyl)]-glycine
FROST, A. E., Freedman, H. H., Westerback, S., & Martell, A. E. (1958) · Journal of the American Chemical Society · doi:10.1021/ja01536a006 · Cited by 84
Modulation of T2 Relaxation Time by Light-Induced, Reversible Aggregation of Magnetic Nanoparticles
Osborne, E. A., Jarrett, B. R., Tu, C., & Louie, A. Y. (2010) · Journal of the American Chemical Society · doi:10.1021/ja100254m · Cited by 84
Supkowski, R. M., & Horrocks, W. D. (1999) · Inorganic Chemistry · doi:10.1021/ic990597n · Cited by 83
Comparison of divalent transition metal ion paraCEST MRI contrast agents
Dorazio, S. J., Olatunde, A. O., Tsitovich, P. B., & Morrow, J. R. (2013) · JBIC Journal of Biological Inorganic Chemistry · doi:10.1007/s00775-013-1059-4 · Cited by 83
Peptide targeted tripod macrocyclic Gd(III) chelates for cancer molecular MRI
Zhou, Z., Wu, X., Kresak, A. M., et al. (2013) · Biomaterials · doi:10.1016/j.biomaterials.2013.06.057 · Cited by 82
A EuII‐Containing Cryptate as a Redox Sensor in Magnetic Resonance Imaging of Living Tissue
Ekanger, L. A., Polin, L., Shen, Y., Haacke, E. M., Martin, P. D., & Allen, M. J. (2015) · Angewandte Chemie International Edition · doi:10.1002/anie.201507227 · Cited by 82
Activatable T 1 and T 2 Magnetic Resonance Imaging Contrast Agents
Tu, C., Osborne, E. A., & Louie, A. Y. (2011) · Annals of Biomedical Engineering · doi:10.1007/s10439-011-0270-0 · Cited by 80
Engineering Gd-loaded nanoparticles to enhance MRI sensitivity viaT1shortening
Bruckman, M. A., Yu, X., & Steinmetz, N. F. (2013) · Nanotechnology · doi:10.1088/0957-4484/24/46/462001 · Cited by 80
Nejadnik, H., Ye, D., Lenkov, O. D., Donig, J., Martin, J. E., Castillo, R., Derugin, N., Sennino, B., Rao, J., & Daldrup-Link, H. E. (2015) · ACS Nano · doi:10.1021/nn504494c · Cited by 80
A Janus Chelator Enables Biochemically Responsive MRI Contrast with Exceptional Dynamic Range
Gale, E. M., Jones, C. M., Ramsay, I. A., Farrar, C. T., & Caravan, P. D. (2016) · Journal of the American Chemical Society · doi:10.1021/jacs.6b10898 · Cited by 80
Self-citationWAGONER, M. V., O'toole, M., Worah, D., et al. (1991) · Investigative Radiology · doi:10.1097/00004424-199111000-00010 · Cited by 79
Rivlin, M., Tsarfaty, I., & Navon, G. (2014) · Magnetic Resonance in Medicine · doi:10.1002/mrm.25467 · Cited by 78
Pereira, G. A. L., Peters, J. A., Paz, F. A. A., Rocha, J., & Geraldes, C. F. G. C. (2010) · Inorganic Chemistry · doi:10.1021/ic9025014 · Cited by 78
How Does Internal Motion Influence the Relaxation of the Water Protons in LnIIIDOTA-like Complexes?
Dunand, F. A., Borel, A., & Merbach, A. E. (2002) · Journal of the American Chemical Society · doi:10.1021/ja016873q · Cited by 78
Coronary Arteries: Contrast-enhanced MR Imaging with SH L 643A—Experience in 12 Volunteers
Herborn, C. U., Barkhausen, J., Paetsch, I., Hunold, P., Mahler, M., Shamsi, K., & Nagel, E. C. (2003) · Radiology · doi:10.1148/radiol.2291021033 · Cited by 78
Molecular imaging of oxidized collagen quantifies pulmonary and hepatic fibrogenesis
Chen, H. H., Waghorn, P. A., Wei, L., Tapias, L. F., Schühle, D. T., Rotile, N. J., Jones, C. M., Looby, R. J., Zhao, G., Elliott, J., et al. (2017) · JCI Insight · doi:10.1172/jci.insight.91506 · Cited by 78
Self-citationTombach, B., Benner, T., Reimer, P., Schuierer, G. R., Fallenberg, E. M., Geens, V., WELS, T., & Sorensen, A. G. (2003) · Radiology · doi:10.1148/radiol.2263011970 · Cited by 77
Pasha, A., Tircsó, G., Benyó, E. T., Brücher, E., & Sherry, A. D. (2007) · European Journal of Inorganic Chemistry · doi:10.1002/ejic.200700354 · Cited by 76
Fine-tuning water exchange on GdIII poly(amino carboxylates) by modulation of steric crowding
Jászberényi, Z., Sour, A., Tóth, É., et al. (2005) · Dalton Transactions · doi:10.1039/b506702b · Cited by 75
The Challenge of Connecting the Dots in the B.R.A.I.N.
Devor, A., Bandettini, P. A., Boas, D. A., Bower, J. M., Buxton, R. B., Cohen, L. B., Dale, A. M., Einevoll, G. T., Fox, P. T., Franceschini, M. A., et al. (2013) · Neuron · doi:10.1016/j.neuron.2013.09.008 · Cited by 75
Coman, D., Trübel, H., & Hyder, F. (2009) · NMR in Biomedicine · doi:10.1002/nbm.1461 · Cited by 73
Molecular Magnetic Resonance Imaging of Tumor Response to Therapy
Shuhendler, A. J., Ye, D., Brewer, K., Bazalova‐Carter, M., Lee, K. H., Kempen, P. J., Wittrup, K. D., Graves, E. E., Rutt, B. K., & Rao, J. (2015) · Scientific Reports · doi:10.1038/srep14759 · Cited by 73
Molecular Magnetic Resonance Imaging of Lung Fibrogenesis with an Oxyamine‐Based Probe
Waghorn, P. A., Jones, C. M., Rotile, N. J., Koerner, S. K., Ferreira, D. S., Chen, H. H., Probst, C. K., Tager, A. M., & Caravan, P. D. (2017) · Angewandte Chemie International Edition · doi:10.1002/anie.201704773 · Cited by 72
Self-citationGadolinium-based contrast agents in pediatric magnetic resonance imaging
Gale, E. M., Caravan, P. D., Rao, A. G., McDonald, R. J., Winfeld, M. J., Fleck, R. J., & Gee, M. S. (2017) · Pediatric Radiology · doi:10.1007/s00247-017-3806-0 · Cited by 71
Self-citationFarrar, C. T., DePeralta, D. K., Day, H., Rietz, T. A., Wei, L., Lauwers, G. Y., Keil, B. R., Subramaniam, A., Sinskey, A. J., Tanabe, K. K., et al. (2015) · Journal of Hepatology · doi:10.1016/j.jhep.2015.04.029 · Cited by 70
Self-citationRelaxivity modulation in Gd-functionalised mesoporous silicas
Carniato, F., Tei, L., Dastrù, W., Marchese, L., & Botta, M. (2009) · Chemical Communications · doi:10.1039/b820591d · Cited by 70
Hanaoka, K., Kikuchi, K., Terai, T., Komatsu, T., & Nagano, T. (2007) · Chemistry - A European Journal · doi:10.1002/chem.200700785 · Cited by 70
Preda, A., Novikov, V., Möglich, M., Turetschek, K., Shames, D. M., Brasch, R. C., CAVAGNA, F. M., & Roberts, T. P. L. (2004) · Journal of Magnetic Resonance Imaging · doi:10.1002/jmri.20184 · Cited by 70
Glucosamine and N-acetyl glucosamine as new CEST MRI agents for molecular imaging of tumors
Rivlin, M., & Navon, G. (2016) · Scientific Reports · doi:10.1038/srep32648 · Cited by 70
Using iron oxide nanoparticles to diagnose CNS inflammatory diseases and PCNSL
Farrell, B. T., Hamilton, B. E., Dósa, E., Rimely, E., Nasseri, M. N., Gahramanov, S., Lacy, C. A., Frenkel, E. P., Doolittle, N. D., Jacobs, P. M., et al. (2013) · Neurology · doi:10.1212/wnl.0b013e31829bfd8f · Cited by 69
Wagner, M., Wagner, S., Schnorr, J., Schellenberger, E. A., Kivelitz, D. E., Krug, L., Dewey, M., Laule, M., Hamm, B., & Taupitz, M. (2011) · Journal of Magnetic Resonance Imaging · doi:10.1002/jmri.22683 · Cited by 69
Splendiani, A., Perri, M., Marsecano, C., Vellucci, V., Michelini, G., Barile, A., & Cesare, E. D. (2017) · La radiologia medica · doi:10.1007/s11547-017-0816-9 · Cited by 69
Divalent metal transporter, DMT1: A novel MRI reporter protein
Bartelle, B. B., Szulc, K. U., Suero‐Abreu, G. A., Rodríguez, J. J., & Turnbull, D. H. (2012) · Magnetic Resonance in Medicine · doi:10.1002/mrm.24509 · Cited by 68
A responsive MRI contrast agent to monitor functional cell status
Himmelreich, U., Aime, S., Hieronymus, T., Justicia, C., Uggeri, F., Zenke, M., & Hoehn, M. (2006) · NeuroImage · doi:10.1016/j.neuroimage.2006.05.009 · Cited by 68
A non-toxic ligand for voxel-based MRI analysis of plaques in AD transgenic mice
Sigurdsson, E. M., Wadghiri, Y. Z., Mosconi, L., Blind, J. A., Knudsen, E., Asuni, A. A., Scholtzova, H., Tsui, W. H., Li, Y., Sadowski, M. J., et al. (2007) · Neurobiology of Aging · doi:10.1016/j.neurobiolaging.2006.12.018 · Cited by 68
Advances in Magnetic Resonance Imaging Contrast Agents for Biomarker Detection
Sinharay, S., & Pagel, M. D. (2016) · Annual Review of Analytical Chemistry · doi:10.1146/annurev-anchem-071015-041514 · Cited by 68
Reimer, P., Müller, M., Marx, C., Wiedermann, D., Muller, R. N., Rummeny, E., Ebert, W., Shamsi, K., & Peters, P. E. (1998) · Radiology · doi:10.1148/radiology.209.3.9844683 · Cited by 67
Lanthanide(III) Complexes with a Reinforced Cyclam Ligand Show Unprecedented Kinetic Inertness
Rodríguez‐Rodríguez, A., Esteban‐Gómez, D., Tripier, R., Tircsó, G., Garda, Z., Tóth, I., Blas, A. D., Rodríguez-Blas, T., & Platas‐Iglesias, C. (2014) · Journal of the American Chemical Society · doi:10.1021/ja511331n · Cited by 67
Self-citationHexameric MnII Dendrimer as MRI Contrast Agent
Zhu, J., Gale, E. M., Atanasova, I. P., Rietz, T. A., & Caravan, P. D. (2014) · Chemistry - A European Journal · doi:10.1002/chem.201403883 · Cited by 67
Self-citationProtease-Specific Nanosensors for Magnetic Resonance Imaging
Schellenberger, E. A., Rudloff, F., Warmuth, C., Taupitz, M., Hamm, B., & Schnorr, J. (2008) · Bioconjugate Chemistry · doi:10.1021/bc800330k · Cited by 66
Pharmacokinetic Behavior of Gadoteridol Injection
McLachlan, S. J., Eaton, S., & Simone, D. N. D. (1992) · Investigative Radiology · doi:10.1097/00004424-199208001-00004 · Cited by 66
Improved paramagnetic liposomes for MRI visualization of pH triggered release
Torres, E., Mainini, F., Napolitano, R., Fedeli, F., Cavalli, R., Aime, S., & Terreno, E. (2011) · Journal of Controlled Release · doi:10.1016/j.jconrel.2011.05.017 · Cited by 65
McAteer, M. A., Mankia, K. S., Ruparelia, N., Jefferson, A., Nugent, H. B., Stork, L., Channon, K. M., Schneider, J. E., & Choudhury, R. P. (2012) · Arteriosclerosis Thrombosis and Vascular Biology · doi:10.1161/atvbaha.111.241844 · Cited by 65
CM-101: Type I Collagen–targeted MR Imaging Probe for Detection of Liver Fibrosis
Farrar, C. T., Gale, E. M., Kennan, R. P., Ramsay, I. A., Masia, R., Arora, G., Looby, K., Wei, L., Kalpathy–Cramer, J., Bunzel, M. M., et al. (2017) · Radiology · doi:10.1148/radiol.2017170595 · Cited by 65
Self-citation19F MRI detection of β-galactosidase activity for imaging of gene expression
Mizukami, S., Matsushita, H., Takikawa, R., Sugihara, F., Shirakawa, M., & Kikuchi, K. (2011) · Chemical Science · doi:10.1039/c1sc00071c · Cited by 64
Dual MRI-SPECT agent for pH-mapping
Gianolio, E., Maciocco, L., Imperio, D., Giovenzana, G. B., Simonelli, F., Abbas, K., Bisi, G., & Aime, S. (2010) · Chemical Communications · doi:10.1039/c0cc03554h · Cited by 64
Synthesis and characterization of a redox- and light-sensitive MRI contrast agent
Tu, C., Osborne, E. A., & Louie, A. Y. (2008) · Tetrahedron · doi:10.1016/j.tet.2008.12.020 · Cited by 63
Schiller, B. M., Bhat, P., & Sharma, A. K. (2013) · Clinical Therapeutics · doi:10.1016/j.clinthera.2013.09.028 · Cited by 63
Davis, R. M., Matsumoto, S., Bernardo, M., Sowers, A. L., Matsumoto, K., Krishna, M. C., & Mitchell, J. B. (2010) · Free Radical Biology and Medicine · doi:10.1016/j.freeradbiomed.2010.11.028 · Cited by 62
Huang, S., Chen, H. H., Yuan, H., Dai, G., Schühle, D. T., Mekkaoui, C., Ngoy, S., Liao, R., Caravan, P. D., Josephson, L., et al. (2011) · Circulation Cardiovascular Imaging · doi:10.1161/circimaging.111.966374 · Cited by 62
Self-citationSynthesis and characterization of a smart contrast agent sensitive to calcium
Dhingra, K., Maier, M. E., Beyerlein, M., Angelovski, G., & Logothetis, N. K. (2008) · Chemical Communications · doi:10.1039/b801975d · Cited by 61
Spuentrup, E., Ruhl, K. M., Botnar, R. M., Wiethoff, A. J., Buhl, A., Jacques, V., Greenfield, M. T., Krombach, G. A., Günther, R. W., Vangel, M. G., et al. (2009) · Circulation · doi:10.1161/circulationaha.108.826388 · Cited by 61
Self-citationZhelev, Z., Bakalova, R., Aoki, I., Lazarova, D., & Saga, T. (2013) · ACS Chemical Neuroscience · doi:10.1021/cn400159h · Cited by 61
Developing imidazoles as CEST MRI pH sensors
Yang, X., Song, X., Banerjee, S. R., Li, Y., Byun, Y., Liu, G., Bhujwalla, Z. M., Pomper, M. G., & McMahon, M. T. (2016) · Contrast Media & Molecular Imaging · doi:10.1002/cmmi.1693 · Cited by 61
Development of hypoxia-sensitive Gd3+-based MRI contrast agents
Iwaki, S., Hanaoka, K., Piao, W., Komatsu, T., Ueno, T., Terai, T., & Nagano, T. (2012) · Bioorganic & Medicinal Chemistry Letters · doi:10.1016/j.bmcl.2012.02.071 · Cited by 60
Strategies for the Preparation of Bifunctional Gadolinium(III) Chelators
Frullano, L., & Caravan, P. D. (2011) · Current Organic Synthesis · doi:10.2174/157017911796117250 · Cited by 60
Self-citationDeleo, M. J., Gounis, M. J., Hong, B., Ford, J. C., Wakhloo, A. K., & Bogdanov, A. A., Jr. (2009) · Radiology · doi:10.1148/radiol.2523081426 · Cited by 60
Zhu, B., Wei, L., Rotile, N. J., Day, H., Rietz, T. A., Farrar, C. T., Lauwers, G. Y., Tanabe, K. K., Rosen, B. R., Fuchs, B. C., et al. (2016) · Hepatology · doi:10.1002/hep.28930 · Cited by 60
Self-citationBotnar, R. M., Wiethoff, A. J., Ebersberger, U., Lacerda, S., Blume, U. A., Warley, A., Jansen, C. H. P., Onthank, D. C., Cesati, R. R. I., Razavi, R., et al. (2014) · Circulation Cardiovascular Imaging · doi:10.1161/circimaging.113.001131 · Cited by 59
Magnetic Resonance Imaging Visualization of Hyaluronidase in Ovarian Carcinoma
Shiftan, L., Israely, T., Cohen, M., Frydman, V., Dafni, H., Stern, R., & Neeman, M. (2005) · Cancer Research · doi:10.1158/0008-5472.can-04-3947 · Cited by 59
Gd3+ complexes conjugated to Pittsburgh compound B: potential MRI markers of β-amyloid plaques
Martins, A. F., Morfin, J., Geraldes, C. F. G. C., & Tóth, É. (2013) · JBIC Journal of Biological Inorganic Chemistry · doi:10.1007/s00775-013-1055-8 · Cited by 58
Naresh, N. K., Xu, Y., Klibanov, A. L., Vandsburger, M. H., Meyer, C. H., Leor, J., Kramer, C. M., French, B. A., & Epstein, F. H. (2012) · Radiology · doi:10.1148/radiol.12111863 · Cited by 58
Molecular MRI of Intracranial Thrombus in a Rat Ischemic Stroke Model
Uppal, R., Ay, İ., Dai, G., Kim, Y. R., Sorensen, A. G., & Caravan, P. D. (2010) · Stroke · doi:10.1161/strokeaha.109.575662 · Cited by 57
Self-citationGadolinium( iii ) based nanoparticles for T 1 -weighted magnetic resonance imaging probes
Yang, C., Padmanabhan, P., & Gulyás, B. Z. (2016) · RSC Advances · doi:10.1039/c6ra07782j · Cited by 57
Calcium-responsive paramagnetic CEST agents
Angelovski, G., Chauvin, T., Pohmann, R., Logothetis, N. K., & Tóth, É. (2010) · Bioorganic & Medicinal Chemistry · doi:10.1016/j.bmc.2010.07.023 · Cited by 56
USPIO-enhanced MR angiography of arteriovenous fistulas in patients with renal failure
Sigovan, M., Gasper, W., Alley, H. F., Owens, C. D., & Saloner, D. (2012) · Radiology · doi:10.1148/radiol.12112694 · Cited by 55
Monovalent and Bivalent Fibrin‐specific MRI Contrast Agents for Detection of Thrombus
Nair, S. A., Kolodziej, A. F., Bhole, G., Greenfield, M. T., McMurry, T. J., & Caravan, P. D. (2008) · Angewandte Chemie International Edition · doi:10.1002/anie.200800563 · Cited by 55
Self-citationOxidation-responsive Eu 2+/3+ -liposomal contrast agent for dual-mode magnetic resonance imaging
Ekanger, L. A., Ali, M. M., & Allen, M. J. (2014) · Chemical Communications · doi:10.1039/c4cc07027e · Cited by 55
Rigid Mn(ii) chelate as efficient MRI contrast agent for vascular imaging
Su, H., Wu, C., Zhu, J., Miao, T., Wang, D., Xia, C., Zhao, X., Gong, Q., Song, B., & Ai, H. (2012) · Dalton Transactions · doi:10.1039/c2dt31696j · Cited by 55
A Comparison of Two MR Hepatobiliary Gadolinium Chelates: Gd-BOPTA and Gd-EOB-DTPA
Runge, V. M. (1998) · Journal of Computer Assisted Tomography · doi:10.1097/00004728-199807000-00026 · Cited by 55
Detecting Enzyme Activities with Exogenous MRI Contrast Agents
Hingorani, D. V., Yoo, B., Bernstein, A. S., & Pagel, M. D. (2014) · Chemistry - A European Journal · doi:10.1002/chem.201402474 · Cited by 55
CEST theranostics: label-free MR imaging of anticancer drugs
Li, Y., Chen, H., Xu, J., Yadav, N. N., Chan, K. W. Y., Luo, L., McMahon, M. T., Vogelstein, B., van Zijl, P. C. M., Zhou, S., et al. (2016) · Oncotarget · doi:10.18632/oncotarget.7141 · Cited by 55
WAGONER, M. V., & Worah, D. (1993) · Investigative Radiology · doi:10.1097/00004424-199303001-00005 · Cited by 54
Wildgruber, M., Bielicki, I., Aichler, M., Kosanke, K., Feuchtinger, A., Settles, M., Onthank, D. C., Cesati, R. R. I., Robinson, S. P., Huber, A. M. A., et al. (2013) · Circulation Cardiovascular Imaging · doi:10.1161/circimaging.113.001270 · Cited by 54
Lebel, R., ̧bska, B. J., Therriault, H., Cournoyer, M., McIntyre, J. O., Escher, E., Neugebauer, W. A., Paquette, B., & Lepage, M. (2008) · Magnetic Resonance in Medicine · doi:10.1002/mrm.21741 · Cited by 54
Tuning Phenols with Intra‐Molecular Bond Shifted HYdrogens (IM‐SHY) as diaCEST MRI Contrast Agents
Yang, X., Yadav, N. N., Song, X., Banerjee, S. R., Edelman, H. E., Minn, I., van Zijl, P. C. M., Pomper, M. G., & McMahon, M. T. (2014) · Chemistry - A European Journal · doi:10.1002/chem.201403943 · Cited by 54
Renal Transplant Imaging Using Magnetic Resonance Angiography With a Nonnephrotoxic Contrast Agent
Bashir, M. R., Jaffe, T. A., Brennan, T. V., Patel, U. D., & Ellis, M. J. (2013) · Transplantation · doi:10.1097/tp.0b013e318295464c · Cited by 54
Fournier, A. P., Quenault, A., Martinez de Lizarrondo, S., Gauberti, M., Defer, G., Vivien, D., Docagne, F., & Macrez, R. (2017) · Proceedings of the National Academy of Sciences · doi:10.1073/pnas.1619424114 · Cited by 54
Gadolinium-binding helix–turn–helix peptides: DNA-dependent MRI contrast agents
Caravan, P. D., Greenwood, J. M., Welch, J., & Franklin, S. J. (2003) · Chemical Communications · doi:10.1039/b307817e · Cited by 53
Self-citationBönner, F., Merx, M. W., Klingel, K., Begovatz, P., Flögel, U., Sager, M., Temme, S., Jacoby, C., Ravesh, M. S., Grapentin, C., et al. (2015) · European Heart Journal - Cardiovascular Imaging · doi:10.1093/ehjci/jev008 · Cited by 53
Tsitovich, P. B., Cox, J. M., Spernyak, J. A., & Morrow, J. R. (2016) · Inorganic Chemistry · doi:10.1021/acs.inorgchem.6b02159 · Cited by 53
An, S. K., Lee, J. M., Suh, K., Lee, N. J., Kim, S. H., Kim, Y., Han, J. K., & Choi, B. I. (2006) · American Journal of Roentgenology · doi:10.2214/ajr.05.0584 · Cited by 52
A Gadolinium Complex Confined in Silica Nanoparticles as a Highly Efficient T1/T2 MRI Contrast Agent
Wartenberg, N., Fries, P. H., Raccurt, O., et al. (2013) · Chemistry - A European Journal · doi:10.1002/chem.201300635 · Cited by 52
Ferumoxytol Use as an Intravenous Contrast Agent for Magnetic Resonance Angiography
Stabi, K. L., & Bendz, L. M. (2011) · Annals of Pharmacotherapy · doi:10.1345/aph.1q431 · Cited by 50
̧bska, B. J., Lebel, R., Therriault, H., McIntyre, J. O., Escher, E., Guérin, B., Paquette, B., Neugebauer, W. A., & Lepage, M. (2009) · Journal of Medicinal Chemistry · doi:10.1021/jm801411h · Cited by 50
Visualization of immune cell infiltration in experimental viral myocarditis by 19F MRI in vivo
Jacoby, C., Borg, N., Heusch, P., Sauter, M., Bönner, F., Kandolf, R., Klingel, K., Schrader, J., & Flögel, U. (2013) · Magnetic Resonance Materials in Physics Biology and Medicine · doi:10.1007/s10334-013-0391-6 · Cited by 50
MRI Sensing of Neurotransmitters with a Crown Ether Appended Gd 3+ Complex
Oukhatar, F., Même, S., Même, W., Szeremeta, F., Logothetis, N. K., Angelovski, G., & Tóth, É. (2014) · ACS Chemical Neuroscience · doi:10.1021/cn500289y · Cited by 50
Structure–Relaxivity Relationships among Targeted MR Contrast Agents
Caravan, P. D., & Zhang, Z. (2012) · European Journal of Inorganic Chemistry · doi:10.1002/ejic.201101364 · Cited by 49
Self-citationTan, M., Burden‐Gulley, S. M., Li, W., et al. (2011) · Pharmaceutical Research · doi:10.1007/s11095-011-0635-y · Cited by 49
Paetsch, I., Huber, M., Bornstedt, A., Schnackenburg, B., Boesiger, P., Stuber, M., Fleck, E., CAVAGNA, F. M., & Nagel, E. C. (2004) · Journal of Magnetic Resonance Imaging · doi:10.1002/jmri.20099 · Cited by 49
Protti, A., Lavín, B., Dong, X., Lorrio, S., Robinson, S. P., Onthank, D. C., Shah, A. M., & Botnar, R. M. (2015) · Journal of the American Heart Association · doi:10.1161/jaha.115.001851 · Cited by 48
Structural Features of Europium(II)‐Containing Cryptates That Influence Relaxivity
Lenora, C. U., Carniato, F., Shen, Y., Latif, Z., Haacke, E. M., Martin, P. D., Botta, M., & Allen, M. J. (2017) · Chemistry - A European Journal · doi:10.1002/chem.201702158 · Cited by 48
Suchý, M., Ta, R. M., Li, A. X., Wojciechowski, F., Pasternak, S., Bartha, R., & Hudson, R. H. E. (2010) · Organic & Biomolecular Chemistry · doi:10.1039/b926639a · Cited by 47
Tissue Redox Activity as a Hallmark of Carcinogenesis: From Early to Terminal Stages of Cancer
Bakalova, R., Zhelev, Z., Aoki, I., & Saga, T. (2013) · Clinical Cancer Research · doi:10.1158/1078-0432.ccr-12-3726 · Cited by 47
A new paramagnetically shifted imaging probe for MRI
Senanayake, P. K., Rogers, N. J., Finney, K. N. A., Harvey, P., Funk, A. M., Wilson, J. I., O’Hogain, D., Maxwell, R. J., Parker, D., & Blamire, A. M. (2016) · Magnetic Resonance in Medicine · doi:10.1002/mrm.26185 · Cited by 46
A europium(iii)-based PARACEST agent for sensing singlet oxygen by MRI
Song, B., Wu, Y., Yu, M., Zhao, P., Zhou, C., Kiefer, G. E., & Sherry, A. D. (2013) · Dalton Transactions · doi:10.1039/c3dt50194a · Cited by 45
Yu, M., Ambrose, S. L., Whaley, Z. L., Fan, S., Gorden, J. D., Beyers, R. J., Schwartz, D. D., & Goldsmith, C. R. (2014) · Journal of the American Chemical Society · doi:10.1021/ja507034d · Cited by 45
Balogh, E., Tripier, R., Ruloff, R., & Tóth, É. (2005) · Dalton Transactions · doi:10.1039/b418991d · Cited by 44
Lin, C.-W., Tseng, S. ‐., Kempson, I. M., Yang, S., Hong, T.-M., & Yang, P. (2013) · Biomaterials · doi:10.1016/j.biomaterials.2013.02.058 · Cited by 44
Cell-Permeable Esterase-Activated Ca(II)-Sensitive MRI Contrast Agent
MacRenaris, K. W., Ma, Z., Krueger, R. L., Carney, C. E., & Meade, T. J. (2015) · Bioconjugate Chemistry · doi:10.1021/acs.bioconjchem.5b00561 · Cited by 44
Pérez‐Mayoral, E., Negri, V., Soler‐Padros, J., Cerdán, S., & Ballesteros, P. (2008) · European Journal of Radiology · doi:10.1016/j.ejrad.2008.02.048 · Cited by 43
Molecular targeting of Alzheimer's amyloid plaques for contrast‐enhanced magnetic resonance imaging
Poduslo, J. F., Wengenack, T. M., Curran, G. L., Wısnıewskı, T., Sigurdsson, E. M., Macura, S. I., Borowski, B., & Jack, C. R. (2002) · Journal of Neurochemistry · doi:10.1046/j.1471-4159.81.s1.20_5.x · Cited by 43
An MRI Method To Map Tumor Hypoxia Using Red Blood Cells Loaded with a pO 2 -Responsive Gd-Agent
Gregorio, E. D., Ferrauto, G., Gianolio, E., Lanzardo, S., Carrera, C., Fedeli, F., & Aime, S. (2015) · ACS Nano · doi:10.1021/acsnano.5b02604 · Cited by 43
Carrera, C., Digilio, G., Baroni, S., Burgio, D., Consol, S., Fedeli, F., Longo, D. L., Mortillaro, A., & Aime, S. (2007) · Dalton Transactions · doi:10.1039/b705088g · Cited by 42
A Magnetic Resonance Imaging Contrast Agent Capable of Detecting Hydrogen Peroxide
Yu, M., Beyers, R. J., Gorden, J. D., Cross, J. N., & Goldsmith, C. R. (2012) · Inorganic Chemistry · doi:10.1021/ic3012603 · Cited by 42
Li, W., Luo, J. H., & Chen, Z. (2010) · Dalton Transactions · doi:10.1039/c0dt01141j · Cited by 41
Dual contrast perfusion MRI in a single imaging session for assessment of pediatric brain tumors
Thompson, E. M., Guillaume, D. J., Dósa, E., Li, X., Nazemi, K. J., Gahramanov, S., Hamilton, B. E., & Neuwelt, E. A. (2012) · Journal of Neuro-Oncology · doi:10.1007/s11060-012-0872-x · Cited by 41
Matsumura, S., Aoki, I., Saga, T., & Shiba, K. (2011) · Molecular Pharmaceutics · doi:10.1021/mp2001999 · Cited by 41
Molecular MR imaging of fibrosis in a mouse model of pancreatic cancer
Polášek, M., Yang, Y., Schühle, D. T., Yaseen, M. A., Kim, Y. R., Sung, Y. S., Guimarães, A. R., & Caravan, P. D. (2017) · Scientific Reports · doi:10.1038/s41598-017-08838-6 · Cited by 40
Self-citationDaly, C. (2007) · Nephrology Dialysis Transplantation · doi:10.1093/ndt/gfm445 · Cited by 38
Jung, K., Kim, H., Lee, G. H., Kang, D.-S., Park, J. A., Kim, K. M., Chang, Y., & Kim, T. (2011) · Journal of Medicinal Chemistry · doi:10.1021/jm2002052 · Cited by 38
Yu, M., Ward, M. B., Franke, A., Ambrose, S. L., Whaley, Z. L., Bradford, T. M., Gorden, J. D., Beyers, R. J., Cattley, R. C., Ivanović‐Burmazović, I., et al. (2017) · Inorganic Chemistry · doi:10.1021/acs.inorgchem.6b02964 · Cited by 38
Xue, S., Qiao, J., Jiang, J., Hubbard, K., White, N. O., Wei, L., Li, S., Liu, Z., & Yang, J. J. (2014) · Medicinal Research Reviews · doi:10.1002/med.21313 · Cited by 37
MR Coronary Angiography with SH L 643 A: Initial Experience in Patients with Coronary Artery Disease
Herborn, C. U., Schmidt, M., Bruder, O., Nagel, E. C., Shamsi, K., & Barkhausen, J. (2004) · Radiology · doi:10.1148/radiol.2332031545 · Cited by 37
Albumin-binding PARACEST agents
Ali, M. M., Woods, M., Suh, E. H., Kovács, Z., Tircsó, G., Zhao, P., Kodibagkar, V. D., & Sherry, A. D. (2007) · JBIC Journal of Biological Inorganic Chemistry · doi:10.1007/s00775-007-0240-z · Cited by 37
A Myelin-Specific Contrast Agent for Magnetic Resonance Imaging of Myelination
Frullano, L., Wang, C., Miller, R. H., & Wang, Y. (2011) · Journal of the American Chemical Society · doi:10.1021/ja1040896 · Cited by 37
Cited by
Rare-Earth Doping in Nanostructured Inorganic Materials
Zheng, B., Fan, J., Chen, B., Qin, X., Wang, J., Wang, F., Deng, R., & Liu, X. (2022) · Chemical Reviews · doi:10.1021/acs.chemrev.1c00644 · Cited by 1,204
Marshall, C. M., Federice, J. G., Bell, C. N., Cox, P. B., & Njardarson, J. T. (2024) · Journal of Medicinal Chemistry · doi:10.1021/acs.jmedchem.4c01122 · Cited by 1,064
Ha, M., Kim, J.-H., You, M., Li, Q., Fan, C., & Nam, J.-M. (2019) · Chemical Reviews · doi:10.1021/acs.chemrev.9b00234 · Cited by 466
Classification of Metal-Based Drugs according to Their Mechanisms of Action
Boros, E., Dyson, P. J., & Gasser, G. (2020) · Chem · doi:10.1016/j.chempr.2019.10.013 · Cited by 437
Yan, R., Hu, Y., Liu, F., Wei, S., Fang, D., Shuhendler, A. J., Liu, H., Chen, H.-Y., & Ye, D. (2019) · Journal of the American Chemical Society · doi:10.1021/jacs.9b03649 · Cited by 389
Metadata
- Authors
- Wahsner, J., Gale, E. M., Rodríguez-Rodríguez, A., & Caravan, P.
- Venue
- Chemical Reviews
- Publisher
- American Chemical Society (ACS)
- Published
- 2018-10-16
- Volume
- 119
- Issue
- 2
- Pages
- 957-1057
- ISSN
- 0009-2665 (ISSN-L)
- 1520-6890
- OpenAlex
- W2896682297
- Cited by
- 1,603
- References
- 450
- FWCI
- 4.53
- Type
- journal article
- Language
- en
- Open access
- green
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.