Quantitative Protection Factors for Common Masks and Face Coverings
Open accessThe DOI matches its Crossref record; 23 of the 23 references it cites were found in a registry or an index.
Abstract
The performance of masks, whether intended to protect the community from exhaled infectious aerosol or to protect the wearer from inhaled infectious aerosol, depends on factors such as filtration efficiency, particle size distribution, leakage, and ventilation rate. These factors depend on the activities and facial features of the mask wearer so that the mask performance for real-world applications is difficult to predict. The present work shows how protection factor, a quantity often used to describe mask performance, can be estimated without involving human volunteers. By constraining these factors to known values, mask protection factors can be compared fairly and efficiently following a series of filtration efficiency measurements performed in the laboratory. Protection factors and mask emissions for exhalation and inhalation were evaluated for masks of seven types currently in use around the world and for a hypothetical mask with 99% efficiency on all particles. The performance of reusable masks made from cotton fabric was limited by the size of the native cotton fibers. Masks that utilized finer fibers, particularly electret fibers with relatively small diameters, showed excellent performance with moderate flow resistance. Results from this work, in addition to simple guidance for mask fit and usage, can facilitate risk communication and decision-making efforts during the COVID-19 pandemic.
Overview
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
Claims other papers make about this one
Each is checked against this paper’s own text: does it say what the citing paper says it does?
In the citing paper
“Other factors potentially affecting inhalation mask efficiency but not considered in this work include particle liquid content as a function of temperature and humidity; inhalation rate dependence on exercise, speaking [56], individual physiology, or demographics; particle charge dependence; and degradation after multiple uses [57].”
From Comparative Mask Protection against Inhaling Wildfire Smoke, Allergenic Bioaerosols, and Infectious Particles (2022) · cites this paper as [56]
Citations
Cites
Morawska, L., Johnson, G. R., Ristovski, Z. D., Hargreaves, M., Mengersen, K., Corbett, S., Chao, C. Y. H., Li, Y., & Katoshevski, D. (2009) · Journal of Aerosol Science · doi:10.1016/j.jaerosci.2008.11.002 · Cited by 1,129
Aerosol Emission and Superemission during Human Speech Increase with Voice Loudness
Asadi, S., Wexler, A. S., Cappa, C. D., Barreda, S., Bouvier, N. M., & Ristenpart, W. D. (2019) · Scientific Reports · doi:10.1038/s41598-019-38808-z · Cited by 919
The size distribution of droplets in the exhaled breath of healthy human subjects
PAPINENI, R. S., & ROSENTHAL, F. S. (1997) · Journal of Aerosol Medicine · doi:10.1089/jam.1997.10.105 · Cited by 690
The coronavirus pandemic and aerosols: Does COVID-19 transmit via expiratory particles?
Asadi, S., Bouvier, N., Wexler, A. S., & Ristenpart, W. D. (2020) · Aerosol Science and Technology · doi:10.1080/02786826.2020.1749229 · Cited by 680
Characterizing exhaled airflow from breathing and talking
Gupta, J. K., Lin, C.-H., & Chen, Q. (2010) · Indoor Air · doi:10.1111/j.1600-0668.2009.00623.x · Cited by 564
Asadi, S., Cappa, C. D., Barreda, S., Wexler, A. S., Bouvier, N. M., & Ristenpart, W. D. (2020) · Scientific Reports · doi:10.1038/s41598-020-72798-7 · Cited by 480
Inward and outward effectiveness of cloth masks, a surgical mask, and a face shield
(2020) · doi:10.1101/2020.11.18.20233353 · Cited by 186
Inward and Outward Effectiveness of Cloth Masks, a Surgical Mask, and a Face Shield
Pan, J., Harb, C., Leng, W., & Marr, L. C. (2021) · Aerosol Science and Technology · doi:10.1080/02786826.2021.1890687 · Cited by 186
Molecular insights into the physiology of the ‘thin film’ of airway surface liquid
Boucher, R. C. (1999) · The Journal of Physiology · doi:10.1111/j.1469-7793.1999.0631u.x · Cited by 173
Clapp, P. W., Sickbert-Bennett, E. E., Samet, J. M., Berntsen, J., Zeman, K. L., Anderson, D. J., Weber, D. J., Bennett, W. D., & Program, U. C. F. D. C. A. P. E. (2021) · JAMA Internal Medicine · doi:10.1001/jamainternmed.2020.8168 · Cited by 167
Research works printed but not linked: 6
- 2019, Procedure No. TEB-APR-STP-0059 Revision 3.2, Determination of Particulate Filter Efficiency Level for N95 Series Filters Against Solid Particulates for Non-Powered, Air-Purifying Respirators Standard Testing Procedure (STP)
- 2017, Designation: F2299/F2299M-03 Standard Test Method for Determining the Initial Efficiency of Materials Used in Medical Face Masks to Penetration by Particulates Using Latex Spheres
- 2009, EN 149: 2001+A1 Respiratory protective devices – Filtering half masks to protect against particles – Requirements, testing, marking
- 2009, OSHA 3352–02 2009 Assigned Protection Factors for the Revised Respiratory Protection Standard
- 2020, Community face coverings – guide to minimum requirements, methods of testing and use
- AATC, 2020, M14–2020 Guidance and considerations for general purpose textile face coverings: adult
Cited by
Respiratory aerosols and droplets in the transmission of infectious diseases
Pöhlker, M. L., Pöhlker, C., Krüger, O. O., Förster, J., Berkemeier, T., Elbert, W., Fröhlich‐Nowoisky, J., Pöschl, U., Bagheri, G., Bodenschatz, E., et al. (2023) · Reviews of Modern Physics · doi:10.1103/revmodphys.95.045001 · Cited by 228
“…context of the current COVID-19 pandemic – has grown considerably (e.g., Asadi et al., 2020b; Cheng et al., 2021; Clapp et al., 2020; Drewnick et al., 2020; Gandhi and Marr, 2021; Leith et al., 2021; Li et al., 2020; Lindsley et al., 2021; Mitze et al., 2020; Pan et al., 2020; Rogak et al., 2020).”
BackgroundKodros, J. K., O’Dell, K., Samet, J. M., L’Orange, C., Pierce, J. R., & Volckens, J. (2021) · GeoHealth · doi:10.1029/2021gh000482 · Cited by 93
“The PF is a function of the filtration efficiency of the mask (the fraction of particles the mask collects assuming all air passes through the mask) and how well it fits over the face (influencing the leak rate or the amount of air that bypasses the mask itself) (Leith et al., 2021).”
BackgroundSelf-citationControl of airborne infectious disease in buildings: Evidence and research priorities
de Mesquita, P. J. B., Delp, W. W., Chan, W. R., Bahnfleth, W. P., & Singer, B. C. (2021) · Indoor Air · doi:10.1111/ina.12965 · Cited by 69
Lindsley, W. G., Blachère, F. M., Beezhold, D. H., Law, B. F., Derk, R. C., Hettick, J. M., Woodfork, K. A., Goldsmith, W. T., Harris, J. R., Duling, M. G., et al. (2021) · Aerosol Science and Technology · doi:10.1080/02786826.2021.1933377 · Cited by 57
Risk assessment of airborne COVID-19 exposure in social settings
Ooi, C. C., Suwardi, A., Yang, Z., Xu, G. X., Tan, C. K. I., Daniel, D., Li, H., Ge, Z., Leong, F. Y., Marimuthu, K., et al. (2021) · Physics of Fluids · doi:10.1063/5.0055547 · Cited by 36
Chen, Z., Zhang, W., Yang, H., Min, K., Jiang, J., Lü, D., Huang, X. F., Qu, G., Liu, Q. S., & Jiang, G. (2022) · Environmental Science Processes & Impacts · doi:10.1039/d1em00509j · Cited by 31
Bhattacharjee, S., Bahl, P., Chughtai, A. A., Heslop, D. J., & MacIntyre, C. R. (2022) · Nano Select · doi:10.1002/nano.202200101 · Cited by 28
Chiera, S., Cristoforetti, A., Benedetti, L., Nollo, G., Borro, L., Mazzei, L., & Tessarolo, F. (2022) · International Journal of Environmental Research and Public Health · doi:10.3390/ijerph19063548 · Cited by 30
“This concept could also be further integrated in more complex models [51] to quantify the protection factors of face masks and optimize their production and use toward a lower risk in airborne pathogen infection.”
BackgroundThe effectiveness of filter material for respiratory protection worn by wildland firefighters
Garg, P., Wang, S., Oakes, J. M., Bellini, C. M., & Gollner, M. J. (2023) · Fire Safety Journal · doi:10.1016/j.firesaf.2023.103811 · Cited by 29
Lee, K., Jung, Y.-W., Park, H., Kim, D., & Kim, J. (2021) · ACS Applied Materials & Interfaces · doi:10.1021/acsami.1c16850 · Cited by 18
Safety and Reverence: How Roman Catholic Liturgy Can Respond to the COVID-19 Pandemic
Budaev, S. V. (2020) · Journal of Religion and Health · doi:10.1007/s10943-021-01282-x · Cited by 17
Wagner, J., Macher, J. M., Chen, W., & Kumagai, K. (2022) · International Journal of Environmental Research and Public Health · doi:10.3390/ijerph192315555 · Cited by 14
Kong, M., Li, L., Eilts, S. M., Li, L., Hogan, C. J., & Pope, Z. (2022) · ACS ES&T Engineering · doi:10.1021/acsestengg.1c00321 · Cited by 12
Volckens, J., Good, K. M., Goble, D., Good, N., Keller, J. P., Keisling, A., L’Orange, C., Morton, E., Phillips, R., & Tanner, K. (2022) · Scientific Reports · doi:10.1038/s41598-022-15530-x · Cited by 15
Self-citationSegovia, J. M., Huang, C.-H. S., Mamishev, M., Yuan, N., He, J., & Novosselov, I. V. (2022) · Applied Sciences · doi:10.3390/app12189360 · Cited by 13
Filtration and Breathability of Nonwoven Fabrics Used in Washable Masks
Bement, T. W., Downey, D. J., Mitros, A., Lau, R., Sipkens, T. A., Songer, J., Alexander, H., Ostrom, D., Nikookar, H., & Rogak, S. N. (2022) · Aerosol and Air Quality Research · doi:10.4209/aaqr.220044 · Cited by 11
“Firstly, most common fabrics can easily remove particles above > 5 µm (Leith et al., 2021), so evaluation at larger sizes does not help differentiate between good candidate materials.”
BackgroundPastor‐Satorras, R., & Castellano, C. (2022) · Scientific Reports · doi:10.1038/s41598-022-20152-4 · Cited by 7
“The mean-field equations for the SIS model in a homogeneous network of degree ki = K depend only on the densities of infected adopting and nonadopting individuals Ia , and take the form30,32 (28) θ̇ = f αo İ1 + (1− f )İ0 ≃ −θ + c θ .”
MethodIntegration of IoT Sensors to Determine Life Expectancy of Face Masks
Mudiyanselage, V. R., Lee, K., & Hassani, A. (2022) · Sensors · doi:10.3390/s22239463 · Cited by 6
“Mask performance can be categorized into the efficiency of the filtration of a mask and the breathability of a mask [11].”
BackgroundLiu, L., Tang, P., & Li, R. (2022) · Environmental Science Water Research & Technology · doi:10.1039/d2ew00154c · Cited by 3
Araújo, F. D. A., Júnior, A. A. M. P., & Weber, R. P. (2023) · Materials Research · doi:10.1590/1980-5373-mr-2023-0044 · Cited by 4
“For example, typical facemask filters have a diameter range of approximately 12 to 20 μm, while N95 respirators have a diameter range of approximately 2 to 7 μm 37,38 .”
BackgroundImpulse dispersion of aerosols during playing the recorder and evaluation of safety measures
Köberlein, M. C., Hermann, L. A., Gantner, S., Tur, B., Peters, G., Westphalen, C., Benthaus, T., Döllinger, M., Kniesburges, S., & Echternach, M. (2022) · PLoS ONE · doi:10.1371/journal.pone.0266991 · Cited by 6
“A proper fit of coverings has been showed to be crucial for protection effectiveness [40].”
BackgroundSimulating real-life scenarios to better understand the spread of diseases under different contexts
Blanco, R., Patow, G., & Pelechano, N. (2024) · Scientific Reports · doi:10.1038/s41598-024-52903-w · Cited by 2
“Furthermore, considering the results obtained, the number of infected persons almost tripled in all scenarios when comparing wearing masks against no masks, which is to be expected as our framework was written considering that wearing a mask reduces the probability of contagion 46 .”
BackgroundInfluentialBritten, A. J. (2024) · Aerosol Science and Technology · doi:10.1080/02786826.2024.2369629 · Cited by 2
“…efficiency above 3.8 m m. Extrapolating the EF(d) data was not ideal, but the smooth and approximately linear nature of our data and the previously reported approximately linear EF(d) curves (Leith, L’Orange, and Volckens 2021; Lindsley et al. 2021) shows that this extrapolation is reasonable.”
InfluentialHuang, Z., Nie, X., Liu, N., Fan, G., Xu, S., & Deng, Q. (2026) · Chemical Engineering Journal · doi:10.1016/j.cej.2026.173239 · Cited by 1
Sosnowski, T. R., Morawska, L., Szczepańska, J., Szajna, E., Vilkotsky, A. I., Odziomek, M., & Sosnowski, K. (2023) · Advanced Powder Technology · doi:10.1016/j.apt.2023.104143 · Cited by 1
Piai, K. D. A. (2022) · Digital Library of Theses and Dissertations (Universidade de São Paulo) · doi:10.11606/d.6.2022.tde-07062022-144835
L’Orange, C. (2022) · doi:10.64628/aai.74a4cnf5m
Self-citationde Meijere, G., Martin, H., & IRMAR, U. D. R. (2026) · Mathematical Biosciences & Engineering · doi:10.3934/mbe.2026014
“95) [38, 36] Ratio of the decision-making rate over the recovery rate (0 , 5) q ∈ (0 , ∞ ) Ratio of the isolation-breaking rate over the recovery rate (0 , 2) κ ∈ (0 , ∞ ) Rescaled rate of opinion update (0 , 50) Relative importance given to prevalence in the ‘Defect’ strategy Rescaled cost to…”
Martin, H., Castella, F., & Hamelin, F. (2026) · Journal of Theoretical Biology · doi:10.1016/j.jtbi.2026.112395 · Cited by 3
Metadata
- Authors
- Leith, D., L’Orange, C., & Volckens, J.
- Affiliations
- University of North Carolina at Chapel Hill (US)
- Colorado State University (US)
- Corresponding author
- Volckens, John
- Venue
- Environmental Science & Technology
- Publisher
- American Chemical Society (ACS)
- Published
- 2021-02-18
- Volume
- 55
- Issue
- 5
- Pages
- 3136-3143
- ISSN
- 0013-936X (ISSN-L)
- 1520-5851
- OpenAlex
- W3129426227
- Cited by
- 29
- References
- 22
- Citations by year
- 2026: 3 · 2024: 2 · 2023: 4 · 2022: 14 · 2021: 5
- FWCI
- 4.04
- Type
- journal article
- Language
- en
- Open access
- hybrid
- doi.org
- Licence
- Locations
- Environmental Science & Technology (publishedVersion, cc-by-nc-nd)
- PubMed (publishedVersion)
- Carolina Digital Repository (University of North Carolina at Chapel Hill) (submittedVersion, cc-by-nc-nd)
- UNC Libraries
- Funders
- World Health Organization
- Topics
- Health Sciences › Medicine › Pulmonary and Respiratory Medicine › Infection Control and Ventilation
- Physical Sciences › Engineering › Electrical and Electronic Engineering › Aerosol Filtration and Electrostatic Precipitation
- Social Sciences › Sociology and Political Science › COVID-19 Prevention and Impact
- Keywords
- face masks, face coverings, protection factor, filtration efficiency, airborne transmission, mask leak, mask fit, flow resistance, COVID-19 pandemic, risk communication
- MeSH terms
- COVID-19, SARS-CoV-2, Aerosols, Humans, Masks, Pandemics
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.