The DOI matches its Crossref record; 1 of the 1 references it cites were found in a registry or an index.
Flow-Electrode Capacitive Deionization Using an Aqueous Electrolyte with a High Salt Concentration
Abstract
Flow-electrode capacitive deionization (FCDI) is novel capacitive deionization (CDI) technology that exhibits continuous deionization and a high desalting efficiency. A flow-electrode with high capacitance and low resistance is required for achieving an efficient FCDI system with low energy consumption. For developing high-performance flow-electrode, studies should be conducted considering porous materials, conductive additives, and electrolytes constituting the flow-electrode. Here, we evaluated the desalting performances of flow-electrodes with spherical activated carbon and aqueous electrolytes containing various concentrations of NaCl in the FCDI unit cell for confirming the effect of salt concentration on the electrolyte of a flow-electrode on desalting efficiency. We verified the necessity of a moderate amount of salt in the flow-electrode for compensating for the reduction in the performance of the flow-electrode, attributed to the resistance of water used as the electrolyte. Simultaneously, we confirmed the potential use of salt water with a high salt concentration, such as seawater, as an aqueous electrolyte for the flow-electrode.
Overview
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Desalination via a New Membrane Capacitive Deionization Process Utilizing Flow-Electrodes
Jeon, S.-I., Park, H.-R., Yeo, J.-G., Yang, S., Cho, C. H., Han, M. H., & Kim, D. K. (2013) · Energy & Environmental Science · doi:10.1039/c3ee24443a · Cited by 727
Self-citation
Cited by
Zhang, C., Ma, J., Wu, L., Sun, J., Wang, L., Li, T., & Waite, T. D. (2021) · Environmental Science & Technology · doi:10.1021/acs.est.0c06552 · Cited by 323
Comparison of energy consumption in desalination by capacitive deionization and reverse osmosis
Qin, M., Deshmukh, A., Epsztein, R., Patel, S. K., Owoseni, O. M., Walker, W. S., & Elimelech, M. (2019) · Desalination · doi:10.1016/j.desal.2019.01.003 · Cited by 292
Energy Efficiency of Capacitive Deionization
Wang, L., Dykstra, J. E., & Lin, S. (2019) · Environmental Science & Technology · doi:10.1021/acs.est.8b04858 · Cited by 292
Folaranmi, G., Bechelany, M., Sistat, P., Cretin, M., & Zaviska, F. (2020) · Membranes · doi:10.3390/membranes10050096 · Cited by 149
Choi, S., Chang, B., Kang, J. H., Diallo, M. S., & Choi, J. W. (2017) · Journal of Membrane Science · doi:10.1016/j.memsci.2017.07.043 · Cited by 60
Metadata
- Authors
- Yang, S., Choi, J., Yeo, J.-G., Jeon, S.-I., Park, H.-R., & Kim, D. K.
- Venue
- Environmental Science & Technology
- Publisher
- American Chemical Society (ACS)
- Published
- 2016-05-18
- Volume
- 50
- Issue
- 11
- Pages
- 5892-5899
- ISSN
- 0013-936X (ISSN-L)
- 1520-5851
- OpenAlex
- W2386068351
- Cited by
- 224
- References
- 1
- FWCI
- 8.21
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.