The DOI matches its Crossref record; 63 of the 63 references it cites were found in a registry or an index.
Energy-Efficient Electrochemical Oxidation of Perfluoroalkyl Substances Using a Ti4O7 Reactive Electrochemical Membrane Anode
Abstract
An energy-efficient Magnéli phase Ti 4 O 7 reactive electrochemical membrane (REM) was applied for the oxidation of perfluorooctanoic acid (PFOA) and perfluorooctanesulfonic acid (PFOS). Approximately 5-log removal of these compounds was achieved in a single pass through the REM with residence times of ∼11 s at 3.3 V/SHE for PFOA and 3.6 V/SHE for PFOS. The permeate concentrations of PFOA and PFOS were <86 and 35 ng L –1, from initial concentrations of 4.14 and 5 mg L –1, respectively. The highest removal rates were 3415 ± 203 μmol m –2 h –1 for PFOA and 2436 ± 106 μmol m –2 h –1 for PFOS at a permeate flux of 720 L m –2 h –1 (residence times of ∼3.8 s). The levels of energy consumption (per log removal) to remove PFOA and PFOS to below the detection limits were 5.1 and 6.7 kWh m –3, respectively. These values are the lowest reported for electrochemical oxidation and approximately an order of magnitude lower than those reported for other technologies (i.e., ultrasonication, photocatalysis, vacuum ultraviolet photolysis, and microwave–hydrothermal decomposition), demonstrating the promise of the REM technology for water treatment applications.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Critical review of electrochemical advanced oxidation processes for water treatment applications
Chaplin, B. P. (2014) · Environ. Sci.: Processes Impacts · doi:10.1039/c3em00679d · Cited by 862
Self-citationBentel, M. J., Yu, Y., Xu, L., Li, Z., Wong, B. M., Men, Y., & Liu, J. (2019) · Environmental Science & Technology · doi:10.1021/acs.est.8b06648 · Cited by 648
Novel treatment technologies for PFAS compounds: A critical review
Kucharzyk, K. H., Darlington, R., Benotti, M., Deeb, R., & Hawley, E. (2017) · Journal of Environmental Management · doi:10.1016/j.jenvman.2017.08.016 · Cited by 562
Trojanowicz, M., Bojanowska-Czajka, A., Bartosiewicz, I., & Kulisa, K. (2018) · Chemical Engineering Journal · doi:10.1016/j.cej.2017.10.153 · Cited by 550
The Prospect of Electrochemical Technologies Advancing Worldwide Water Treatment
Chaplin, B. P. (2019) · Accounts of Chemical Research · doi:10.1021/acs.accounts.8b00611 · Cited by 494
Self-citationRemoval of perfluorinated surfactants by sorption onto granular activated carbon, zeolite and sludge
Ochoa-Herrera, V., & Sierra-Alvarez, R. (2008) · Chemosphere · doi:10.1016/j.chemosphere.2008.04.029 · Cited by 482
Lin, H., Niu, J., Ding, S., & Zhang, L. (2012) · Water Research · doi:10.1016/j.watres.2012.01.053 · Cited by 472
Hori, H., Hayakawa, E., Einaga, H., Kutsuna, S., Koike, K., Ibusuki, T., Kiatagawa, H., & Arakawa, R. (2004) · Environmental Science & Technology · doi:10.1021/es049719n · Cited by 465
Sonochemical Decomposition of Perfluorooctane Sulfonate and Perfluorooctanoic Acid
Moriwaki, H., Takagi, Y., Tanaka, M., Tsuruho, K., Okitsu, K., & Maeda, Y. (2005) · Environmental Science & Technology · doi:10.1021/es040342v · Cited by 464
Houtz, E. F., Sutton, R., Park, J.-S., & Sedlak, M. (2016) · Water Research · doi:10.1016/j.watres.2016.02.055 · Cited by 374
Cited by
MOF based engineered materials in water remediation: Recent trends
Rego, R. M., Kuriya, G., Kurkuri, M. D., & Kigga, M. (2021) · Journal of Hazardous Materials · doi:10.1016/j.jhazmat.2020.123605 · Cited by 384
Electrified Membranes for Water Treatment Applications
Sun, M., Wang, X., Winter, L. R., Zhao, Y., Ma, W., Hedtke, T., Kim, J.-H., & Elimelech, M. (2021) · ACS ES&T Engineering · doi:10.1021/acsestengg.1c00015 · Cited by 320
Hydroxyl radicals in anodic oxidation systems: generation, identification and quantification
Xie, J., Zhang, C., & Waite, T. D. (2022) · Water Research · doi:10.1016/j.watres.2022.118425 · Cited by 303
Radjenovic, J., Duinslaeger, N., Avval, S. S., & Chaplin, B. P. (2020) · Environmental Science & Technology · doi:10.1021/acs.est.0c06212 · Cited by 268
Self-citationO’Connor, J., Bolan, N. S., Kumar, M., Nitai, A. S., Ahmed, M. B., Bolan, S. S., Vithanage, M., Rinklebe, J., Mukhopadhyay, R., Srivastava, P., et al. (2022) · Process Safety and Environmental Protection · doi:10.1016/j.psep.2022.06.002 · Cited by 183
Veciana, M., Bräunig, J., Farhat, A., Pype, M.-L., Freguia, S., Carvalho, G., Keller, J., & Ledezma, P. (2022) · Journal of Hazardous Materials · doi:10.1016/j.jhazmat.2022.128886 · Cited by 148
Ahmadi, M., Adeleye, O., Vonalt, G., & Nazemi, M. (2025) · Environmental Science & Technology · doi:10.1021/acs.est.5c04748 · Cited by 41
Metadata
- Authors
- Le, T. X. H., Haflich, H., Shah, A. D., & Chaplin, B. P.
- Venue
- Environmental Science & Technology Letters
- Publisher
- American Chemical Society (ACS)
- Published
- 2019-07-24
- Volume
- 6
- Issue
- 8
- Pages
- 504-510
- ISSN
- 2328-8930 (ISSN-L)
- OpenAlex
- W2962744115
- Cited by
- 297
- References
- 63
- FWCI
- 12.63
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.