The DOI matches its Crossref record; 15 of the 15 references it cites were found in a registry or an index.
Guanine-Based DNA Biosensor Amplified with Pt/SWCNTs Nanocomposite as Analytical Tool for Nanomolar Determination of Daunorubicin as an Anticancer Drug: A Docking/Experimental Investigation
Abstract
Daunorubicin is a famous anthracycline anticancer chemotherapy drug with many side effects that is very important to measure in biological samples. A daunorubicin electrochemical biosensor was fabricated in this study using ds-DNA as the biorecognition element and glassy carbon electrode (GCE) amplified by Pt/SWCNTs as a sensor. The synthetization of Pt/SWCNTs was done by the polyol method, and their characterization was accomplished via XRD, EDS, and TEM methods. The results showed a diameter of about 5.0 nm for the Pt nanoparticle decorated at the surface of SWCNTs. The morphological and conductivity properties of Pt/SWCNTs/GCE were investigated by EIS and AFM methods, and the results confirmed that Pt/SWCNTs/GCE had a high surface area and high conductivity. ds-DNA/Pt/SWCNTs/GCE showed an oxidation signal relative to that of the guanine base at the potential of 847 mV and a positive shift after interaction with the daunorubicin anticancer drug. This point confirms the intercalation reaction between the guanine base in the ds-DNA structure and the drug that could be used as an analytical factor for the determination of daunorubicin. Furthermore, molecular docking study is used to predict the interaction site of daunorubicin with DNA. It is found that daunorubicin interacts with guanine bases of DNA via an intercalative mode. Kinetic investigation showed an association equilibrium constant ( K a ) of about 5.044 × 10 3 M –1 between ds-DNA and daunorubicin. The differential pulse voltammetric results showed a linear dynamic range of 4.0 nM to 250.0 μM with a detection limit of 1.0 nM for determination of daunorubicin on the surface of ds-DNA/Pt/SWCNTs/GCE. Finally, ds-DNA/Pt/SWCNTs/GCE was successfully used for the determination of daunorubicin in injection samples with a recovery range of 98.27–10313%.
Overview
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
1 retracted
Alizadeh, M., Azar, P. A., Mozaffari, S. A., Karimi‐Maleh, H., & Tamaddon, A. M. (2020) · Frontiers in Chemistry · doi:10.3389/fchem.2020.00677 · Cited by 29
Self-citationRetractedElectrochemical biosensors for pathogen detection
Cesewski, E., & Johnson, B. N. (2020) · Biosensors and Bioelectronics · doi:10.1016/j.bios.2020.112214 · Cited by 902
Carbon nanotube-enhanced electrochemical DNA biosensor for DNA hybridization detection
Cai, H., Cao, X., Jiang, Y., He, P., & Fang, Y. (2003) · Analytical and Bioanalytical Chemistry · doi:10.1007/s00216-002-1652-9 · Cited by 431
Karimi-Maleh, H., Tahernejad-Javazmi, F., Atar, N., Yola, M. L., Gupta, V. K., & Ensafi, A. A. (2015) · Industrial & Engineering Chemistry Research · doi:10.1021/ie504438z · Cited by 412
Self-citationElectrochemical biosensors for the detection of lung cancer biomarkers: A review
Khanmohammadi, A., Aghaie, A., Vahedi, E., Qazvini, A., Ghanei, M., Afkhami, A., Hajian, A., & Bagheri, H. (2020) · Talanta · doi:10.1016/j.talanta.2019.120251 · Cited by 358
Karimi-Maleh, H., Shojaei, A. F., Tabatabaeian, K., Karimi, F., Shakeri, S., & Moradi, R. (2016) · Biosensors and Bioelectronics · doi:10.1016/j.bios.2016.07.086 · Cited by 293
Self-citationBiosensors for wastewater monitoring: A review
Ejeian, F., Etedali, P., Mansouri-Tehrani, H.-A., Soozanipour, A., Low, Z.-X., Asadnia, M., Taheri-Kafrani, A., & Razmjou, A. (2018) · Biosensors and Bioelectronics · doi:10.1016/j.bios.2018.07.019 · Cited by 287
Orooji, Y., Sohrabi, H., Hemmat, N., Oroojalian, F., Baradaran, B., Mokhtarzadeh, A., Mohaghegh, M., & Karimi-Maleh, H. (2021) · Nano-Micro Letters · doi:10.1007/s40820-020-00533-y · Cited by 206
Self-citationElectrochemical biosensors based on nucleic acid aptamers
Villalonga, A., Pérez-Calabuig, A. M., & Villalonga, R. (2020) · Analytical and Bioanalytical Chemistry · doi:10.1007/s00216-019-02226-x · Cited by 184
Mohammad, M., Razmjou, A., Liang, K., Asadnia, M., & Chen, V. (2018) · ACS Applied Materials & Interfaces · doi:10.1021/acsami.8b16837 · Cited by 143
Cited by
Karimi-Maleh, H., Yola, M. L., Atar, N., Orooji, Y., Karimi, F., Senthil Kumar, P., Rouhi, J., & Baghayeri, M. (2021) · Journal of Colloid and Interface Science · doi:10.1016/j.jcis.2021.02.066 · Cited by 404
Self-citationAghaei, A., Shaterian, M., Danafar, H., Likozar, B., Šuligoj, A., & Gyergyek, S. (2023) · Microchimica Acta · doi:10.1007/s00604-023-05761-8 · Cited by 7
Metadata
- Authors
- Karimi-Maleh, H., Alizadeh, M., Orooji, Y., Karimi, F., Baghayeri, M., Rouhi, J., Tajik, S., Beitollahi, H., Agarwal, S., Gupta, V. K., Rajendran, S., Rostamnia, S., Fu, L., Saberi-Movahed, F., & Malekmohammadi, S.
- Venue
- Industrial & Engineering Chemistry Research
- Publisher
- American Chemical Society (ACS)
- Published
- 2021-01-08
- Volume
- 60
- Issue
- 2
- Pages
- 816-823
- ISSN
- 0888-5885 (ISSN-L)
- 1520-5045
- OpenAlex
- W3119276753
- Cited by
- 408
- References
- 15
- FWCI
- 27.58
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: Guanine-Based DNA Biosensor Amplified with Pt/SWCNTs Nanocomposite as Analytical Tool for Nanomolar Determination of Daunorubicin as an Anticancer Drug: A Docking/Experimental Investigation. https://app.cochat.ai/papers/10.1021/acs.iecr.0c04698
- The paper
- Karimi-Maleh, H., Alizadeh, M., Orooji, Y., Karimi, F., Baghayeri, M., Rouhi, J., Tajik, S., Beitollahi, H., Agarwal, S., Gupta, V. K., Rajendran, S., Rostamnia, S., Fu, L., Saberi-Movahed, F., & Malekmohammadi, S. (2021). Guanine-Based DNA Biosensor Amplified with Pt/SWCNTs Nanocomposite as Analytical Tool for Nanomolar Determination of Daunorubicin as an Anticancer Drug: A Docking/Experimental Investigation. Industrial & Engineering Chemistry Research. https://doi.org/10.1021/acs.iecr.0c04698
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.