CoChat

Model-Based Approach for the Evaluation of Materials and Processes for Post-Combustion Carbon Dioxide Capture from Flue Gas by PSA/VSA Processes

Nikolaidis, George N., Kikkinides, Eustathios S., Georgiadis, Michael C. · 2016 · Industrial & Engineering Chemistry Research
Cited by 45

The DOI matches its Crossref record; 2 of the 2 references it cites were found in a registry or an index.

Abstract

This work presents a mathematical modeling framework for the simulation and optimization of PSA/VSA processes for postcombustion CO 2 capture from dry flue gas (85% N 2, 15% CO 2 ). The modeling framework is first validated against literature data, illustrating good agreement in terms of several process performance indicators. Accordingly, the model is used to evaluate three available potential adsorbents for CO 2 capture, namely, zeolite 13X, activated carbon and metal organic framework (MOF), Mg-MOF-74. A two-bed configuration (six-step VSA cycle) with light product pressurization has been employed in all simulations. The results from systematic comparative simulations demonstrate that zeolite 13X has the best process performance among the three adsorbents, in terms of CO 2 purity and CO 2 recovery. On the other hand, Mg-MOF-74 appears to be a promising adsorbent for CO 2 capture, as it has considerably higher CO 2 productivity compared to the other two adsorbents. Furthermore, process optimization studies using zeolite 13X and Mg-MOF-74, have been performed to minimize energy consumption for specified minimum requirements in CO 2 purity and in CO 2 recovery at nearly atmospheric feed pressures. The optimization results indicate that the minimum target of 90% in CO 2 purity and 90% in CO 2 recovery is met for the VSA process under consideration for both adsorbents at different operating conditions resulting in different energy requirements. Thus, there is a complex relationship between optimal process performance indicators and operating conditions that varies among the different adsorbents and cannot be quantified by simple comparison of CO 2 /N 2 adsorption isotherms and selectivity data. Evidently, detailed process modeling, simulation and optimization strategies, provide the most reliable way to evaluate both qualitatively and quantitatively potential adsorbents for CO 2 capture.

Overview

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Integrity signals

Registry

Crossref · 10.1021/acs.iecr.5b02845

Cites

2 of 2 references verified0 citation errors · 0 not checkable

Statistics

Verification

Claims the paper makes

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Self-check

Percentages, sums and reported differences re-computed from the paper’s own numbers.

The self-check needs the paper’s full text.

Citations

Cites

Cited by

See all 45

Metadata

Authors
Nikolaidis, G. N., Kikkinides, E. S., & Georgiadis, M. C.
Venue
Industrial & Engineering Chemistry Research
Published
2016-01-19
Volume
55
Issue
3
Pages
635-646
ISSN
  • 0888-5885 (ISSN-L)
  • 1520-5045
OpenAlex
W2228286113
Cited by
45
References
2
FWCI
5.90
Type
journal article
Language
en
Open access
closed

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review

Data sources

Bibliographic data: Semantic Scholar, OpenAlex, Crossref.

Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).

Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.