The DOI matches its Crossref record; 1 of the 1 references it cites were found in a registry or an index.
Tuning the Kinetic Water Stability and Adsorption Interactions of Mg-MOF-74 by Partial Substitution with Co or Ni
Open accessAbstract
Varying amounts of Co and Ni were substituted into the metal–organic framework Mg-MOF-74 via a one-pot solvothermal reaction, and the effects of these substitutions on CO 2 adsorption and kinetic water stability properties were examined. Based on elemental analyses, Co and Ni are more favorably incorporated into the MOF-74 framework from solution than Mg. In addition, reaction temperature more strongly impacts the final metal composition in these mixed-metal (MM) MOF-74 structures than does the reaction solvent composition. Single-component CO 2 adsorption isotherms were measured for the MM-MOF-74 systems at 5, 25, and 45 °C, and isosteric heats of adsorption were calculated. These results suggest that CO 2 adsorption properties can be adjusted by partial metal substitution. Water adsorption isotherms were also measured for the MM-MOF-74 samples, with powder X-ray diffraction patterns and Brunauer–Emmett–Teller surface areas measured both before and after water exposure. Results show that Mg-MOF-74 can gain partial kinetic water stability by the incorporation of Ni 2+ or Co 2+ metal ions that are less vulnerable to hydrolysis than Mg 2+ . Of particular note, Mg–Ni-MM-MOF-74 shows a significant increase in water stability when incorporating as little as 16 mol % Ni into the Mg-MOF-74 structure.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Metal-organic framework materials as catalysts
Lee, J., Farha, O. K., Roberts, J., Scheidt, K. A., Nguyen, S. T., & Hupp, J. T. (2009) · Chemical Society Reviews · doi:10.1039/b807080f · Cited by 7,969
Cited by
Direct Capture of CO2 from Ambient Air
Sanz-Pérez, E. S., Murdock, C. R., Didas, S. A., & Jones, C. W. (2016) · Chemical Reviews · doi:10.1021/acs.chemrev.6b00173 · Cited by 2,406
MOF-Based Membranes for Gas Separations
Qian, Q., Asinger, P. A., Lee, M. J., Han, G., Mizrahi Rodriguez, K., Lin, S., Benedetti, F. M., Wu, A. X., Chi, W. S., & Smith, Z. P. (2020) · Chemical Reviews · doi:10.1021/acs.chemrev.0c00119 · Cited by 1,553
Mixed-metal metal–organic frameworks
Abednatanzi, S., Gohari Derakhshandeh, P., Depauw, H., Coudert, F.-X., Vrielinck, H., Van Der Voort, P., & Leus, K. (2019) · Chemical Society Reviews · doi:10.1039/c8cs00337h · Cited by 741
Yan, L., Cao, L., Dai, P., Gu, X., Liu, D., Li, L., Wang, Y., & Zhao, X. (2017) · Advanced Functional Materials · doi:10.1002/adfm.201703455 · Cited by 738
Destruction of Metal–Organic Frameworks: Positive and Negative Aspects of Stability and Lability
Feng, L., Wang, K.-Y., Day, G. S., Ryder, M. R., & Zhou, H.-C. (2020) · Chemical Reviews · doi:10.1021/acs.chemrev.0c00722 · Cited by 662
Metadata
- Authors
- Jiao, Y., Morelock, C. R., Burtch, N. C., Mounfield, W. P., Hungerford, J. T., & Walton, K. S.
- Venue
- Industrial & Engineering Chemistry Research
- Publisher
- American Chemical Society (ACS)
- Published
- 2015-12-02
- Volume
- 54
- Issue
- 49
- Pages
- 12408-12414
- ISSN
- 0888-5885 (ISSN-L)
- 1520-5045
- OpenAlex
- W2501797864
- Cited by
- 208
- References
- 1
- FWCI
- 6.13
- Type
- journal article
- Language
- en
- Open access
- green
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.