CoChat

Protein Ions Generated by Native Electrospray Ionization: Comparison of Gas Phase, Solution, and Crystal Structures

Bakhtiari, Maryam, Konermann, Lars · 2019 · The Journal of Physical Chemistry B
Cited by 73

The DOI matches its Crossref record; 8 of the 8 references it cites were found in a registry or an index.

Abstract

Experiments and molecular dynamics (MD) simulations in the literature indicate that gaseous proteins generated by electrospray ionization (ESI) can retain native-like structures. However, the exact properties of these ions remain to be explored. Focusing on ubiquitin and lysozyme, we examined several pertinent questions. (1) We applied solvent MD runs to test whether the X-ray structures of both proteins are affected by crystal packing. Main and side-chain orientations were retained in solution, providing a justification for the hitherto unscrutinized approach of relying on crystal data for “solution” versus gas-phase comparisons. (2) Most earlier gas-phase protein MD investigations employed short (ns) simulation windows. By extending this time frame to 1 μs, we were able to observe rare unfolding/folding transitions in ubiquitin. These predicted fluctuations were consistent with a semi-unfolded subpopulation detected by ion mobility spectrometry (IMS). (3) Most earlier modeling studies did not account for the high H + mobility in gaseous proteins. For the first time, we compared static and mobile H + simulations, focusing on both positively and negatively charged ions. The MD runs revealed a strong preference for retention of a solution-like backbone fold, whereas titratable/polar side chains collapsed onto the protein surface. This side-chain collapse was caused by a multitude of intramolecular salt bridges, H-bonds, and charge–dipole interactions. Our results generalize the findings of Steinberg et al. ( ChemBioChem, 2008, 9, 2417–2423) who had first proposed the occurrence of such side-chain contacts on the basis of short-term simulations with static H + . (4) Calculated collision cross sections of the MD conformers were in close agreement with IMS experiments. Overall, this study supports the view that solution-like protein structures can be retained because of kinetic trapping on the time scale of typical ESI–IMS experiments.

Overview

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Integrity signals

Registry

Crossref · 10.1021/acs.jpcb.8b12173

Cites

8 of 8 references verified0 citation errors · 0 not checkable

Statistics

Verification

Claims the paper makes

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Self-check

Percentages, sums and reported differences re-computed from the paper’s own numbers.

The self-check needs the paper’s full text.

Citations

Cites

Cited by

See all 73

Metadata

Authors
Bakhtiari, M., & Konermann, L.
Venue
The Journal of Physical Chemistry B
Published
2019-02-06
Volume
123
Issue
8
Pages
1784-1796
ISSN
  • 1520-5207 (ISSN-L)
  • 1520-6106
OpenAlex
W2914829148
Cited by
73
References
8
FWCI
3.96
Type
journal article
Language
en
Open access
closed

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review

Data sources

Bibliographic data: Semantic Scholar, OpenAlex, Crossref.

Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).

Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.