Student or educator? Sign up with your school email and get 6 months of Pro free.
Cited by 255

The DOI matches its Crossref record; 29 of the 29 references it cites were found in a registry or an index.

Upconverting Nanoparticles Working As Primary Thermometers In Different Media

Balabhadra, Sangeetha, Debasu, Mengistie L., Brites, Carlos D. S., Ferreira, Rute A. S., Carlos, Luís D.·2017·The Journal of Physical Chemistry C

Abstract

In the past decade, noninvasive luminescent thermometry has become popular due to the limitations of traditional contact thermometers to operate at scales below 100 μm, as required by current demands in disparate areas. Generally, the calibration procedure requires an independent measurement of the temperature to convert the thermometric parameter (usually an intensity ratio) to temperature. A new calibration procedure is necessary whenever the thermometer operates in a different medium. However, recording multiple calibrations is a time-consuming task, and not always possible to perform, e.g., in living cells and in electronic devices. Typically, a unique calibration relation is assumed to be valid, independent of the medium, which is a bottleneck of the secondary luminescent thermometers developed up to now. Here we report a straightforward method to predict the temperature calibration curve of any upconverting thermometer based on two thermally coupled electronic levels independently of the medium, demonstrating that these systems are intrinsically primary thermometers. SrF 2:Yb/Er powder and water suspended nanoparticles were used as an illustrative example.

Overview

The claims and statistics of this paper haven’t been checked yet.

Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.

A few free checks a day · papers already verified open instantly · results are public

Integrity signals

Registry

Crossref · 10.1021/acs.jpcc.7b04827

Cites

29 of 29 references verified0 citation errors · 0 not checkable

Statistics

Verification

Claims the paper makes

The claims and statistics of this paper haven’t been checked yet.

Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.

A few free checks a day · papers already verified open instantly · results are public

Self-check

Percentages, sums and reported differences re-computed from the paper’s own numbers.

The self-check needs the paper’s full text.

Citations

Cites

Cited by

See all 255

Metadata

Authors
Balabhadra, S., Debasu, M. L., Brites, C. D. S., Ferreira, R. A. S., & Carlos, L. D.
Venue
The Journal of Physical Chemistry C
Published
2017-06-19
Volume
121
Issue
25
Pages
13962-13968
ISSN
  • 1932-7447 (ISSN-L)
  • 1932-7455
OpenAlex
W2623760193
Cited by
255
References
29
FWCI
11.63
Type
journal article
Language
en
Open access
closed

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review

Data sources

Bibliographic data: Semantic Scholar, OpenAlex, Crossref.

Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).

Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.