Student or educator? Sign up with your school email and get 6 months of Pro free.
Cited by 271

The DOI matches its Crossref record; 30 of the 30 references it cites were found in a registry or an index.

Sensitive Deep Ultraviolet Photodetector and Image Sensor Composed of Inorganic Lead-Free Cs3Cu2I5 Perovskite with Wide Bandgap

Zhang, Zhi-Xiang, Li, Chen, Lu, Yu, Tong, Xiao-Wei, Liang, Feng-Xia, Zhao, Xing-Yuan, Wu, Di, Xie, Chao, Luo, Lin-Bao·2019·The Journal of Physical Chemistry Letters

Abstract

In this work, a sensitive deep ultraviolet (DUV) light photodetector based on inorganic and lead-free Cs 3 Cu 2 I 5 crystalline film derived by a solution method was reported. Optoelectronic characterization revealed that the perovskite device exhibited nearly no sensitivity to visible illumination with wavelength of 405 nm but exhibited pronounced sensitivity to both DUV and UV light illumination with response speeds of 26.2/49.9 ms for rise/fall time. The I light / I dark ratio could reach 127. What is more, the responsivity and specific detectivity were calculated to be 64.9 mA W –1 and 6.9 × 10 11 Jones, respectively. In addition, the device could keep its photoresponsivity after storage in air environment for a month. It is also found that the capability of Cs 3 Cu 2 I 5 crystalline film device can readily record still DUV image with acceptable resolution. The above results confirm that the DUV photodetector may hold great potential for future DUV optoelectronic device and systems.

Overview

The claims and statistics of this paper haven’t been checked yet.

Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.

A few free checks a day · papers already verified open instantly · results are public

Integrity signals

Registry

Crossref · 10.1021/acs.jpclett.9b02390

Cites

30 of 30 references verified0 citation errors · 0 not checkable

Statistics

Verification

Claims the paper makes

The claims and statistics of this paper haven’t been checked yet.

Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.

A few free checks a day · papers already verified open instantly · results are public

Self-check

Percentages, sums and reported differences re-computed from the paper’s own numbers.

The self-check needs the paper’s full text.

Citations

Cites

Show all 30 references

Cited by

See all 271

Metadata

Authors
Zhang, Z.-X., Li, C., Lu, Y., Tong, X.-W., Liang, F.-X., Zhao, X.-Y., Wu, D., Xie, C., & Luo, L.-B.
Venue
The Journal of Physical Chemistry Letters
Published
2019-08-27
Volume
10
Issue
18
Pages
5343-5350
ISSN
1948-7185 (ISSN-L)
OpenAlex
W2970362642
Cited by
271
References
30
FWCI
9.96
Type
journal article
Language
en
Open access
closed

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review

How to cite

Cite CoChat for the checks on this page, and the paper for its own findings.

This page
CoChat. (2026). Citation check: Sensitive Deep Ultraviolet Photodetector and Image Sensor Composed of Inorganic Lead-Free Cs3Cu2I5 Perovskite with Wide Bandgap. https://app.cochat.ai/papers/10.1021/acs.jpclett.9b02390
The paper
Zhang, Z.-X., Li, C., Lu, Y., Tong, X.-W., Liang, F.-X., Zhao, X.-Y., Wu, D., Xie, C., & Luo, L.-B. (2019). Sensitive Deep Ultraviolet Photodetector and Image Sensor Composed of Inorganic Lead-Free Cs3Cu2I5 Perovskite with Wide Bandgap. The Journal of Physical Chemistry Letters. https://doi.org/10.1021/acs.jpclett.9b02390

Data sources

Bibliographic data: Semantic Scholar, OpenAlex, Crossref.

Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).

Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.