CoChat

Solvent-Dependent Adsorption of Perfluorosulfonated Ionomers on a Pt(111) Surface Using Atomic Force Microscopy

The DOI matches its Crossref record; 42 of the 42 references it cites were found in a registry or an index.

Abstract

The adsorption behavior of perfluorosulfonated ionomers (PFSIs) on a Pt(111) surface in various solvents is investigated by in situ atomic force microscopy (AFM) and discussed on the basis of aggregation of PFSIs in the liquid phase. The AFM images show that, in an aqueous solution of PFSI (0.1 wt % Nafion + 99.9 wt % water), PFSI aggregates with a lateral size of 20-200 nm adsorb on the Pt(111) surface. In a PFSI solution containing a small amount of 1-propanol (0.1 wt % Nafion + 99.5 wt % water + 0.4 wt % 1-propanol), however, slightly smaller aggregates adsorb on the Pt(111) surface. Such solvent-dependent sizes of adsorbed aggregates are in reasonable agreement with apparent hydrodynamic radii of PFSIs in the corresponding solutions determined by dynamic light scattering (DLS) while assuming the formation of spherical aggregation. Interestingly, a step-terrace structure characteristic to a clean Pt(111) surface is observed in a propanol-rich PFSI solution (0.1 wt % Nafion + 44.45 wt % water + 55.45 wt % 1-propanol) but X-ray photoelectron spectroscopy clearly indicates the existence of fluorocarbon species at the Pt(111) surface, suggesting the formation of a smooth adsorbed layer of PFSIs in a lying down configuration. Absence of any features assignable to aggregates in DLS data suggests well-dispersion of PFSIs in such propanol-rich solution without aggregations. Thus, the adsorbed structure of PFSIs at Pt surfaces can be controlled by tuning the composition of mixed so…

Overview

Integrity signals

Registry

Crossref · 10.1021/acs.langmuir.0c02023

Cites

42 of 42 references verified0 citation errors · 0 not checkable

Statistics

Recomputing p-values needs the paper’s full text.

Verification

Claims the paper makes

This paper’s full text isn’t openly available, so its claims and self-check weren’t run. The registry and citation checks still apply.

Claims other papers make about this one

Each is checked against this paper’s own text: does it say what the citing paper says it does?

Citations

Cites

Show all 42 references

Research works printed but not linked: 2

  1. 10.1149/ma2017-02/34/147710.1149/08008.0577ecst · doi:10.1149/ma2017-02/34/147710.1149/08008.0577ecst
  2. Abràmoff M. D., 2004, Biophotonics Int., 11, 36

Cited by

See all 12

Metadata

Authors
Devivaraprasad, R., & Masuda, T.
Affiliations
National Institute for Materials Science (JP)
Corresponding author
Masuda, Takuya
Venue
Langmuir
Published
2020-11-11
Volume
36
Issue
46
Pages
13793-13798
ISSN
  • 0743-7463 (ISSN-L)
  • 1520-5827
OpenAlex
W3104763363
Cited by
11
References
42
Citations by year
2026: 1 · 2025: 2 · 2024: 2 · 2023: 2 · 2022: 2 · 2021: 2
FWCI
0.52
Type
journal article
Language
en
Open access
closed
Locations
  • Langmuir (publishedVersion)
  • PubMed (publishedVersion)
Funders
New Energy and Industrial Technology Development Organization
Topics
  • Physical Sciences › Engineering › Electrical and Electronic Engineering › Fuel Cells and Related Materials
  • Physical Sciences › Chemistry › Physical and Theoretical Chemistry › Electrostatics and Colloid Interactions
  • Physical Sciences › Chemistry › Physical and Theoretical Chemistry › Surface Chemistry and Catalysis
Keywords
perfluorosulfonated ionomer, Nafion, Pt(111), polymer aggregation, 1-propanol, mixed solvents, hydrodynamic radius, step-terrace structure, in situ atomic force microscopy

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review

How to cite

Cite CoChat for the checks on this page, and the paper for its own findings.

This page
CoChat. (2026). Citation check: Solvent-Dependent Adsorption of Perfluorosulfonated Ionomers on a Pt(111) Surface Using Atomic Force Microscopy. https://app.cochat.ai/papers/10.1021/acs.langmuir.0c02023
The paper
Devivaraprasad, R., & Masuda, T. (2020). Solvent-Dependent Adsorption of Perfluorosulfonated Ionomers on a Pt(111) Surface Using Atomic Force Microscopy. Langmuir. https://doi.org/10.1021/acs.langmuir.0c02023

Data sources

Bibliographic data: Semantic Scholar, OpenAlex, Crossref.

Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).

Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.