Student or educator? Sign up with your school email and get 6 months of Pro free.
Cited by 1

The DOI matches its Crossref record; the references it cites are not checked yet.

Interface-Limited Amperometric Cholesterol Biosensing in Ultrathin Pd-NPs-Based-Enzyme Films

Silina, Y.E., Koch, M., Korkmaz, N.·2026·Langmuir

Abstract

This manuscript investigates the limitations of enzyme–electrocatalyst coupling in one-step designed amperometric cholesterol biosensors. One-step electrodeposition from Pd-ChOx-Nafion electrolyte produces a bioinorganic hybrid sensing layer, while preserving the enzyme’s native conformation and biocatalytic activity. Despite structural coupling between Pd and ChOx, the amperometric response remains dominated by enzymatic H2O2 production, indicating that direct electronic communication between ChOx and the electrode is not established. More specifically, we show that direct electron transfer (DET) cannot occur even in ultrathin electrodeposited nanostructured films, likely due to oxygen-dominated electrochemistry. Furthermore, the sensitivity of cholesterol determination using Pd-NPs/ChOx/Nafion-modified electrodes was independent of layer thickness and architecture, highlighting the limitations of the Pd-NPs–enzyme interface. These findings provide mechanistic insight into ultrathin enzyme–electrocatalyst interfaces and are expected to impact the development of next-generation cholesterol biosensors.

Overview

The claims and statistics of this paper haven’t been checked yet.

Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.

A few free checks a day · papers already verified open instantly · results are public

Integrity signals

Registry

Crossref · 10.1021/acs.langmuir.6c01437

Cites

Statistics

Verification

Claims the paper makes

The claims and statistics of this paper haven’t been checked yet.

Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.

A few free checks a day · papers already verified open instantly · results are public

Self-check

Percentages, sums and reported differences re-computed from the paper’s own numbers.

The self-check needs the paper’s full text.

Citations

The citation lists haven’t been fetched yet

Cited by 1

Research works printed but not linked: 38

  1. Haritha, 2022, Amperometric Cholesterol Biosensor Based on Cholesterol Oxidase and Pt-Au/MWNTs Modified Glassy Carbon Electrode, Mater. Today Proc., 50, 34, 10.1016/j.matpr.2021.03.128 · doi:10.1016/j.matpr.2021.03.128
  2. Cevik, 2018, Construction of an Amperometric Cholesterol Biosensor Based on DTP(Aryl)Aniline Conducting Polymer Bound Cholesterol Oxidase, Electroanalysis, 30, 2445, 10.1002/elan.201800248 · doi:10.1002/elan.201800248
  3. Ghosh, 2018, Immobilization of Cholesterol Oxidase: An Overview, Open Biotechnol. J., 12, 176, 10.2174/1874070701812010176 · DOI · Paper page
  4. Vidal, 2004, Amperometric Cholesterol Biosensors Based on the Electropolymerization of Pyrrole and the Electrocatalytic Effect of Prussian-Blue Layers Helped with Self-Assembled Monolayers, Talanta, 64, 655, 10.1016/j.talanta.2004.03.038 · DOI
  5. Saxena, 2011, Covalent Immobilization of Cholesterol Oxidase on Self-Assembled Gold Nanoparticles for Highly Sensitive Amperometric Detection of Cholesterol in Real Samples, Biosens. Bioelectron., 26, 3037, 10.1016/j.bios.2010.12.009 · doi:10.1016/j.bios.2010.12.009
  6. Trujillo, 2021, Nanostructures in Hydrogen Peroxide Sensing, Sensors, 21, 2204, 10.3390/s21062204 · doi:10.3390/s21062204
  7. Chen, 2013, Nanomaterials Based Electrochemical Sensors for Biomedical Applications, Chem. Soc. Rev., 42, 5425, 10.1039/c3cs35518g · DOI · Paper page
  8. Chen, 2012, Recent Advances in Electrochemical Sensing for Hydrogen Peroxide: A Review, Analyst, 137, 49, 10.1039/C1AN15738H · DOI · Paper page
  9. Pollegioni, 1999, Cholesterol Oxidase from Streptomyces Hygroscopicus and Brevibacterium Sterolicum: Effect of Surfactants and Organic Solvents on Activity, Biotechnol. Appl. Biochem., 30, 27, 10.1111/j.1470-8744.1999.tb01155.x · doi:10.1111/j.1470-8744.1999.tb01155.x
  10. Sharma, 2017, Development of a Sensitive Electrochemical Enzymatic Reaction-Based Cholesterol Biosensor Using Nano-Sized Carbon Interdigitated Electrodes Decorated with Gold Nanoparticles, Sensors (Basel)., 17, 2128, 10.3390/s17092128 · doi:10.3390/s17092128
  11. Arya, 2008, Recent Advances in Cholesterol Biosensor, Biosens. Bioelectron., 23, 1083, 10.1016/j.bios.2007.10.018 · DOI · Paper page
  12. Silina, 2021, Electrochemical Operational Principles and Analytical Performance of Pd-Based Amperometric Nanobiosensors, Analyst, 146, 4873, 10.1039/D1AN00882J · doi:10.1039/d1an00882j
  13. Koch, 2025, Investigation of the Binding Kinetics and Electrochemical Properties of in Situ Reconstructed Apo-GOx Using Electrodes with Electrodeposited, Analyst, 150, 3431, 10.1039/D5AN00337G · doi:10.1039/d5an00337g
  14. Schachinger, 2021, Amperometric Biosensors Based on Direct Electron Transfer Enzymes, Molecules., 26, 4525, 10.3390/molecules26154525 · DOI · Paper page
  15. Haghighi, 2013, Direct Electron Transfer from Glucose Oxidase Immobilized on an Overoxidized Polypyrrole Film Decorated with Au Nanoparticles, Colloids Surfaces B Biointerfaces, 103, 566, 10.1016/j.colsurfb.2012.11.010 · doi:10.1016/j.colsurfb.2012.11.010
  16. Malekzad, 2017, Noble Metal Nanoparticles in Biosensors: Recent Studies and Applications, Nanotechnology Rev., 6, 301, 10.1515/ntrev-2016-0014 · DOI · Paper page
  17. Tavahodi, 2017, Direct Electron Transfer of Cellobiose Dehydrogenase on Positively Charged Polyethyleneimine Gold Nanoparticles, ChemPlusChem., 82, 546, 10.1002/cplu.201600453 · DOI
  18. Silina, 2024, One-Step Electrodeposited Hybrid Nanofilms in Amperometric Biosensor Development, Anal. Methods, 16, 2424, 10.1039/D4AY00290C · DOI
  19. Silina, 2021, Electrochemical Operational Principles and Analytical Performance of Pd-Based Amperometric Nanobiosensors, Analyst, 146, 4873, 10.1039/D1AN00882J · doi:10.1039/d1an00882j
  20. Silina, 2024, Mechanistic Aspects of Glycerol Oxidation on Palladium Electrocatalysts in Model Aqueous and Fermentation Media Solutions, Electrochim. Acta, 497, 144479, 10.1016/j.electacta.2024.144479 · doi:10.1016/j.electacta.2024.144479
  21. Zolotukhina, 2023, First Principles of Hydrazine Electrooxidation at Oxide-Free and Oxide-Based Palladium Electrodes in Complex Media, Phys. Chem. Chem. Phys., 25, 9881, 10.1039/D3CP00829K · doi:10.1039/d3cp00829k
  22. Baronas, 2003, The Influence of the Enzyme Membrane Thickness on the Response of Amperometric Biosensors, Sensors, 3, 248, 10.3390/s30700248 · DOI
  23. Dewangan, 2019, A Colorimetric Nanoprobe Based on Enzyme-Immobilized Silver Nanoparticles for the Efficient Detection of Cholesterol, RSC Adv., 9, 42085, 10.1039/C9RA08328F · doi:10.1039/c9ra08328f
  24. El-Naggar, 2017, Purification, Characterization and Amino Acid Content of Cholesterol Oxidase Produced by Streptomyces Aegyptia NEAE 102, BMC Microbiol., 17, 76, 10.1186/s12866-017-0988-4 · doi:10.1186/s12866-017-0988-4
  25. Bokoch, 2004, Steady-State Oxidation of Cholesterol Catalyzed by Cholesterol Oxidase in Lipid Bilayer Membranes on Platinum Electrodes, Anal. Chim. Acta, 519, 47, 10.1016/j.aca.2004.03.030 · doi:10.1016/j.aca.2004.03.030
  26. Hu, 2020, Measurement of the Mass Sensitivity of QCM with Ring Electrodes Using Electrodeposition, Electrochem. commun., 116, 106744, 10.1016/j.elecom.2020.106744 · doi:10.1016/j.elecom.2020.106744
  27. Fu, 2021, Accelerated Electron Transfer in Nanostructured Electrodes Improves the Sensitivity of Electrochemical Biosensors, Adv. Sci. (Weinheim, Baden-Wurttemberg, Ger., 8, 10.1002/advs.202102495 · DOI
  28. Chen, 2020, Fundamentals, Applications, and Future Directions of Bioelectrocatalysis, Chem. Rev., 120, 12903, 10.1021/acs.chemrev.0c00472 · DOI · Paper page
  29. Yan, 2020, Direct Electrochemical Enzyme Electron Transfer on Electrodes Modified by Self-Assembled Molecular Monolayers, Catalysts, 10, 1458, 10.3390/catal10121458 · doi:10.3390/catal10121458
  30. Cui, 2013, Immobilization of Glucose Oxidase into a Nanoporous TiO2 Film Layered on Metallophthalocyanine Modified Vertically-Aligned Carbon Nanotubes for Efficient Direct Electron Transfer, Biosens. Bioelectron., 46, 113, 10.1016/j.bios.2013.02.029 · DOI
  31. Wang, 2006, Electrochemical Biosensors: Towards Point-of-Care Cancer Diagnostics, Biosens. Bioelectron., 21, 1887, 10.1016/j.bios.2005.10.027 · DOI · Paper page
  32. Molaei, 2014, Amperometric Biosensor for Cholesterol Based on Novel Nanocomposite Array Gold Nanoparticles/Acetone-Extracted Propolis/Multiwall Carbon Nanotubes/Gold, Micro Nano Lett., 9, 100, 10.1049/mnl.2013.0664 · doi:10.1049/mnl.2013.0664
  33. Dey, 2010, Development of an Amperometric Cholesterol Biosensor Based on Graphene-Pt Nanoparticle Hybrid Material, J. Phys. Chem. C, 114, 21427, 10.1021/jp105895a · DOI · Paper page
  34. Umar, 2014, Development of Highly Sensitive and Selective Cholesterol Biosensor Based on Cholesterol Oxidase Co-Immobilized with α-Fe2O3Micro-Pine Shaped Hierarchical Structures, Electrochim. Acta, 135, 396, 10.1016/j.electacta.2014.04.173 · doi:10.1016/j.electacta.2014.04.173
  35. Bollella, 2020, Enzyme-Based Biosensors: Tackling Electron Transfer Issues, Sensors, 20, 3517, 10.3390/s20123517 · DOI · Paper page
  36. Yin, 2005, Direct Electrochemistry of Redox Proteins and Enzymes Promoted by Carbon Nanotubes, Sensors, 5, 220, 10.3390/s5040220 · DOI
  37. Cao, 2013, Self-Assembled Glucose Oxidase/Graphene/Gold Ternary Nanocomposites for Direct Electrochemistry and Electrocatalysis, J. Electroanal. Chem., 697, 10, 10.1016/j.jelechem.2013.03.001 · doi:10.1016/j.jelechem.2013.03.001
  38. Saboe, 2017, Biomimetic and Bioinspired Approaches for Wiring Enzymes to Electrode Interfaces, Energy Environ. Sci., 10, 14, 10.1039/C6EE02801B · DOI

Metadata

Authors
Silina, Y. E., Koch, M., & Korkmaz, N.
Venue
Langmuir
Published
2026-07-10
Volume
42
Issue
29
Pages
21039-21048
ISSN
  • 0743-7463
  • 1520-5827
Cited by
1
Language
en
Funders
Deutsche Forschungsgemeinschaft (427949628)

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review

How to cite

Cite CoChat for the checks on this page, and the paper for its own findings.

This page
CoChat. (2026). Citation check: Interface-Limited Amperometric Cholesterol Biosensing in Ultrathin Pd-NPs-Based-Enzyme Films. https://app.cochat.ai/papers/10.1021/acs.langmuir.6c01437
The paper
Silina, Y. E., Koch, M., & Korkmaz, N. (2026). Interface-Limited Amperometric Cholesterol Biosensing in Ultrathin Pd-NPs-Based-Enzyme Films. Langmuir. https://doi.org/10.1021/acs.langmuir.6c01437

Data sources

Bibliographic data: Semantic Scholar, OpenAlex, Crossref.

Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).

Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.