Interfacial and Bulk Water in Ultrathin Films of Nafion, 3M PFSA, and 3M PFIA Ionomers on a Polycrystalline Platinum Surface
The DOI matches its Crossref record; 4 of the 4 references it cites were found in a registry or an index.
Abstract
Water at the interface and in the bulk of ultrathin ionomer films confined to platinum surfaces affects the electrochemical activity and proton transport in electrochemical devices, yet it is little explored. This is the first study wherein the water distribution and the hygroexpansion of three different sulfonated fluoropolymers, varying in the composition and length of sulfonic group terminating side chains, as confined thin films (∼15 nm) on a Pt surface are examined by neutron reflectometry, ellipsometry, and quartz crystal microbalance. For the shorter side-chain perfluorosulfonated acid (PFSA) ionomers, Nafion EW 1100 and 3M EW 725, one to two monolayers equivalent of interfacial water, similar to adsorbed water on bare Pt, under wet conditions (97% humidity) was observed. In contrast, for the longer chain perfluoroimide acid (PFIA) ionomer, five monolayers equivalent of interfacial water was observed. In the bulk phase of the films, the PFIA ionomer exhibited a multilamellar structure comprising a water-rich layer near the interface region whereas the PFSA ionomer had a more uniform distribution of water. Our study for the first time demonstrates the strong effect of the side chain of sulfonated fluoropolymers on the Pt/ionomer interfacial water.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Water Uptake by and Transport Through Nafion® 117 Membranes
Zawodzinski, T. A., Derouin, C., Radzinski, S., Sherman, R. J., Smith, V. T., Springer, T. E., & Gottesfeld, S. (1993) · Journal of The Electrochemical Society · doi:10.1149/1.2056194 · Cited by 1,530
Parallel cylindrical water nanochannels in Nafion fuel-cell membranes
Schmidt-Rohr, K., & Chen, Q. (2008) · Nature Materials · doi:10.1038/nmat2074 · Cited by 1,371
Three-dimensional analysis of Nafion layers in fuel cell electrodes
Lopez-Haro, M., Guétaz, L., Printemps, T., Morin, A., Escribano, S., Jouneau, P.-H., Bayle-Guillemaud, P., Chandezon, F., & Gebel, G. (2014) · Nature Communications · doi:10.1038/ncomms6229 · Cited by 402
DeCaluwe, S. C., Baker, A. M., Bhargava, P., Fischer, J. E., & Dura, J. A. (2018) · Nano Energy · doi:10.1016/j.nanoen.2018.01.008 · Cited by 122
Cited by
Liu, H., Ney, L., Zamel, N., & Li, X. (2022) · Applied Sciences · doi:10.3390/app12083776 · Cited by 85
Mabuchi, T., Huang, S.-F., & Tokumasu, T. (2020) · Macromolecules · doi:10.1021/acs.macromol.9b02725 · Cited by 64
Kosakian, A., Urbina, L. P., Heaman, A., & Secanell, M. (2020) · Electrochimica Acta · doi:10.1016/j.electacta.2020.136204 · Cited by 57
Chowdhury, A., Bird, A., Liu, J., Zenyuk, I. V., Kusoglu, A., Radke, C. J., & Weber, A. Z. (2021) · ACS Applied Materials & Interfaces · doi:10.1021/acsami.1c07611 · Cited by 40
Metadata
- Authors
- Shrivastava, U. N., Fritzsche, H., & Karan, K.
- Venue
- Macromolecules
- Publisher
- American Chemical Society (ACS)
- Published
- 2018-11-28
- Volume
- 51
- Issue
- 23
- Pages
- 9839-9849
- ISSN
- 0024-9297 (ISSN-L)
- 1520-5835
- OpenAlex
- W2903427187
- Cited by
- 51
- References
- 4
- FWCI
- 2.16
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.