Linking Perfluorosulfonic Acid Ionomer Chemistry and High-Current Density Performance in Fuel-Cell Electrodes
Abstract
Transport phenomena are key in controlling the performance of electrochemical energy-conversion technologies and can be highly complex, involving multiple length scales and materials/phases. Material designs optimized for one reactant species transport however may inhibit other transport processes. We explore such trade-offs in the context of polymer-electrolyte fuel-cell electrodes, where ionomer thin films provide the necessary proton conductivity but retard oxygen transport to the Pt reaction site and cause interfacial resistance due to sulfonate/Pt interactions. We examine the electrode overall gas-transport resistance and its components as a function of ionomer content and chemistry. Low-equivalent-weight ionomers allow better dissolved-gas and proton transport due to greater water uptake and low crystallinity but also cause significant interfacial resistance due to the high density of sulfonic acid groups. These effects of equivalent weight are also observed via in situ ionic conductivity and CO displacement measurements. Of critical importance, the results are supported by ex situ ellipsometry and X-ray scattering of model thin-film systems, thereby providing direct linkages and applicability of model studies to probe complex heterogeneous structures. Structural and resultant performance changes in the electrode are shown to occur above a threshold sulfonic-group loading, highlighting the significance of ink-based interactions. Our findings and methodologies are applicable to a variety of solid-state energy-conversion devices and material designs.
Integrity signals
Registry
Cites
Statistics
Claims the paper makes
Claims other papers make about this one
Each is checked against this paper’s own text: does it say what the citing paper says it does?
The interfacial structure depends on the surface properties of the catalyst (such as the concentration of Pt and the crystallinity of the carbon support), thus changing the physical properties of the ionomer, which in turn affects the water absorption, proton conductivity, and gas permeability at the interface.
“Therefore, the interfacial structure depends on the surface properties of the catalyst (such as the concentration of Pt and the crystallinity of the carbon support), thus changing the physical properties of the ionomer, which in turn affects the water absorption, proton conductivity, and gas permeability at the interface [103,104].”
From Recent Advances on PEM Fuel Cells: From Key Materials to Membrane Electrode Assembly (2023) · cites this paper as [104]
The use of short-chain ionomers with low equivalent weight and more sulfonic groups in the cathode catalyst layer can improve the coverage and proton conductivity of ionomers compared with long-chain ionomers.
“The use of short-chain ionomers with low equivalent weight and more sulfonic groups in the cathode catalyst layer (CCL) can improve the coverage and proton conductivity of ionomers compared with long-chain ionomers [104].”
From Recent Advances on PEM Fuel Cells: From Key Materials to Membrane Electrode Assembly (2023) · cites this paper as [104]
Cites
Van Cleve, T., Khandavalli, S., Chowdhury, A., Medina, S., Pylypenko, S., Wang, M., More, K. L., Kariuki, N., Myers, D. J., Weber, A. Z., et al. (2019) · ACS Applied Materials & Interfaces · doi:10.1021/acsami.9b17614 · Cited by 148 · see citing works
Self-citationUnderstanding inks for porous-electrode formation
Hatzell, K. B., Dixit, M. B., Berlinger, S. A., & Weber, A. Z. (2017) · J. Mater. Chem. A · doi:10.1039/c7ta07255d · Cited by 97 · see citing works
Self-citation
Flagged first, then by citations
Cited by
Sorted by citations
Recent Advances on PEM Fuel Cells: From Key Materials to Membrane Electrode Assembly
Mo, S., Du, L., Huang, Z., Chen, J., Zhou, Y., Wu, P., Meng, L., Wang, N., Xing, L., Zhao, M., et al. (2023) · Electrochemical Energy Reviews · doi:10.1007/s41918-023-00190-w · Cited by 277 · see citing works
“Meanwhile, it is necessary to provide high IEC without inducing negative effects on the catalyst and to further provide high oxygen permeability [100, 103, 104, 106, 107].”
- Authors
- Chowdhury, A., Bird, A., Liu, J., Zenyuk, I. V., Kusoglu, A., Radke, C. J., & Weber, A. Z.
- Affiliations
- Lawrence Berkeley National Laboratory (US)
- University of California, Irvine (US)
- University of California, Berkeley (US)
- Corresponding author
- Weber, Adam Z.
- Venue
- ACS Applied Materials & Interfaces
- Publisher
- American Chemical Society (ACS)
- Published
- 2021-09-07
- Volume
- 13
- Issue
- 36
- Pages
- 42579-42589
- ISSN
- 1944-8244 (ISSN-L)
- 1944-8252
- OpenAlex
- W3196934316
- Cited by
- 40
- References
- 2
- Citations by year
- 2026: 3 · 2025: 11 · 2024: 10 · 2023: 7 · 2022: 9
- FWCI
- 1.91
- Type
- journal article
- Language
- en
- Open access
- closed
- Licence
- Locations
- ACS Applied Materials & Interfaces (publishedVersion)
- PubMed (publishedVersion)
- eScholarship (California Digital Library) (submittedVersion)
- OSTI OAI (U.S. Department of Energy Office of Scientific and Technical Information) (submittedVersion)
- Funders
- Office of Energy Efficiency and Renewable Energy (DE-AC02-05CH11231, DE-EE0007270)
- Topics
- Physical Sciences › Engineering › Electrical and Electronic Engineering › Fuel Cells and Related Materials
- Physical Sciences › Energy › Renewable Energy, Sustainability and the Environment › Electrocatalysts for Energy Conversion
- Physical Sciences › Materials Science › Materials Chemistry › Advancements in Solid Oxide Fuel Cells
- Keywords
- perfluorosulfonic acid ionomer, proton exchange membrane fuel cells, oxygen transport, interfacial resistance, equivalent weight, ionomer thin films, proton conductivity, water absorption, crystallinity, CO displacement, ellipsometry, X-ray scattering, electrode performance
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review